1.
MEASURE FROM TOP OF THE CANOPY TO CEILING AND SUBTRACT 1/8" FOR CLEAR-
ANCE.
2.
PLACE THE DUCT COVER TOP INSIDE THE DUCT COVER BASE AND LOWER UNTIL DE-
SIRED HEIGHT IS FOUND. (TO ELIMINATE SCRATCHES, MAKE A MARK ON THE DUCT
COVER TOP FOR THE DESIRED LOWERING POINT BY SUBTRACTING 15" FROM THE TO-
TAL HEIGHT NEEDED.)
3.
USE THE RETAINING SCREWS TO FASTEN IN PLACE.
4.
SLIDE THE DUCT COVER IN PLACE AND FASTEN FROM INSIDE CANOPY USING SHEET
METAL SCREWS.
NOTE: FOR INSTALLATIONS WITH CEILINGS ABOVE 9', USE OPTIONAL CUSTOM FLUES. SEE
PRODUCT LITERATURE FOR DETAILS.
MODEL “A” DIM “B” MAXIMUM “C” DIM
BS
-
PC3024
15”
27”
12”
BS
-
PC3624
15”
27”
12”
BS
-
PC4224
15”
27”
15”
BS
-
PC4824
15”
27”
18”
BS
-
PC5424
15”
27”
24”
BS
-
PC6024
15”
27”
24”
BS
-
PC6024
15”
27”
24”