Aristo Water Purifier
User’s Manual
3.
Installation
3-1. Pre-installation requisites:
1. 230V single phase AC connection not more than 1.5 metres away from the point of
installation of purifier. The wire length supplied with the system is 1.5 metres.
2. Input water supply not more than 2 metres away.
3. Drain for rejected water not more than 2 metres away.
4. Countertop or wall hanging space as per dimensions of the purifier.
5. Input water pressure in the range of 4 to 30 psi.
3-
2. DOs and DON’Ts
1. Do not install the unit at the following places:
Near fire or heater
Near flammable material
In front of any cooling/heating device
A place exposed to rain and snow
A place exposed to direct sunlight
Wet place
Near chemicals (volatile material, organic solvent, etc.)
A place below 0°C or a place with the possibility of dropping below 0°C
A place above 40°C or a place with the possibility of rising above 40°C
2. Use input water in the following parameter range only:
Water pressure: 4
– 30 psi
Water temperature: 5
– 40°C
pH: 6.5
– 8.5
When using water out of above range, discuss with Blue Star since performance may be
impacted.
3. When transporting the unit, do not tilt it over 45°.
4. During installation, adjust the level of the unit using a level gauge. Install the unit at a
place where the surface is flat.
5. When connecting the tube, ensure that it is not bent or pressed down by heavy objects.
6. Adjust the tubes so that drain water does not splash around the area.
7. If the input water pressure is lower than 4 psi, an external booster pump needs to be
installed. If the input water pressure is higher than 30 psi, an external pressure reducing
valve needs to be installed. Blue
Star’s or its authorised dealer’s service personnel will
install these at additional costs.