Function and usage period for air purifying
◆
Adsorb CO, CO
2
, benzene, aldehydes and odor of gasoline etc..
◆
Adsorb poisonous material that is smaller than 1μm in air, as dust, pollen, bacteria, and
virus.
◆
Usage period is 6 months to 1 year. If it is necessary to be changed, purchase new purifier
in the nearest
Blueridge
special engaged maintenance center.
6.4 Clean Outlet Vent and Surface Panel
◆
Clean the surface panel by soft dry cloth or wet cloth with neutral scourer.
◆
It is forbidden to clean surface panel by gasoline, benzene, diluents, cleansing powder etc..
◆
If the guide louver is too dirty, it may be removed to be cleaned. (As narrated below)
Disassembly and installation of guide louver
(1).
Disassemble guide louver
Screw bolts in both ends of guide louver to loose.
Note!
Do not forcibly wipe guide louver when cleaning, otherwise painted surface layer would fall off.
(2). Install guide louver
Rotate guide louver slightly could install the protruding edge of both end into grooves on both
end of guide louver, and then tighten bolts.
6.5 Maintenance before or after Seasonal Use
Check before the seasonal use
◆
Check if there is blockage at inlet or outlet of air conditioner.
◆
Check if the earthing wire has been earthed reliably.
◆
Check if the air filter has been installed well.
◆
In order to start up the air conditioner smoothly after long time’s turned off, turn on the main
power supply 8 hours before turning on the air conditioner.
Maintenance after seasonal use
◆
Clean filter and body of air conditioner.
◆
Cut off the main power supply of air conditioner.
◆
The cooling or heating capacity and sound level are tested before leaving factory.
◆
If the parameter changes, refer to the data offered on nameplate.