Test Run
●
Open the front panel and insert the wireless
module (smart kit) into the reserved interface.
WARNING
• This interface is only compatible with
wireless module (smart kit) provided by
the manufacturer.
For the function introduction and operation
instruction, please refer to the user manual of
Smart kit.
infraed controller plug
5 core
CAUTION
Failure to perform the test run may result in
unit damage, property damage, or personal
injury.
Test Run Instructions
1. Open both the liquid and gas stop valves.
2. Turn on the main power switch and allow the
unit to warm up.
3. Set the air conditioner to COOL mode.
4. For the Indoor Unit
a.
b.
c.
Double check to see if the room
temperature is being registered correctly.
d.
Ensure the manual buttons on the indoor
unit works properly.
Check to see that the drainage system is
unimpeded and draining smoothly.
Ensure there is no vibration or abnormal
noise during operation.
5. For the Outdoor Unit
a. Check to see if the refrigeration system is
leaking.
b. Make sure there is no vibration or
abnormal noise during operation.
c. Ensure the wind, noise, and water
generated by the unit do not disturb your
neighbors or pose a safety hazard.
NOTE: If the unit malfunctions or does not
operate according to your expectations,
please refer to the Troubleshooting section
of the Owner’s Manual before calling
customer service.
Before Test Run
A test run must be performed after the entire
system has been completely installed. Confirm
the following points before performing the test:
a) Indoor and outdoor units are properly
installed.
b) Piping and wiring are properly connected.
c) No obstacles near the inlet and outlet of
the unit that might cause poor performance
or product malfunction.
d) Refrigeration system does not leak.
e) Drainage system is unimpeded and
draining to a safe location.
f) Heating insulation is properly installed.
g) Grounding wires are properly connected.
h) Length of the piping and additional
refrigerant stow capacity have been
recorded.
i) Power voltage is the correct voltage
for the air conditioner.
Page 46
Summary of Contents for BMHH18M22-6C2-6C2
Page 27: ...outdoor Unit Installation Page 27 Outdoor Unit Installation...
Page 28: ...outdoor Unit Installation Page 28...
Page 29: ...outdoor Unit Installation Page 29...
Page 33: ...Refrigerant piping Connection Page 33...
Page 34: ...Refrigerant piping Connection Page 34...
Page 36: ...Refrigerant piping Connection Page 36 Electrical Connections...
Page 37: ...Refrigerant piping Connection Page 37...
Page 38: ...Page 38 Refrigerant piping Connection...
Page 39: ...Page 39...