Bluenergy BATBLU2400LIT Manual Download Page 19

Maximum 4 batteries can be athwart stacked

One or two batteries can be sidelong stacked

Cables connection and batteries system start are same as cabinet installation.

energía indoor

www.Latpower.com

Summary of Contents for BATBLU2400LIT

Page 1: ...energ a indoor www Latpower com Lithium Ion Phosphate Battery BATBLU2400LIT...

Page 2: ...e Items Unpacking and check the Packing List 4 2 Installation Location Installation 5 TROUBLE SHOOTING STEPS 5 1 Problem determination based on 5 2 Preliminary determination steps 6 EMERGENCY SITUATIO...

Page 3: ...ean battery 8 Do not expose battery to flammable or harsh chemicals or vapors 9 Do not paint any part of battery include any internal or external components 10 Do not connect battery with PV solar wir...

Page 4: ...erent type of battery 3 It is prohibited to put the batteries working with faulty or incompatible inverter 4 It is prohibited to disassemble the battery QC tab removed or damaged 5 In case of fire onl...

Page 5: ...range is from 10 to 50 Charging 0 50 discharging 10 50 with excellent discharge performance and cycle life Small size and light weight standard of 19 inch embedded designed module is comfortable for...

Page 6: ...n u m m o C RS485 CAN Working Temperature 0 50 Charge 10 50 Disharge Shelf Temperature 20 60 3 8 3 N U E C V T n o i t a c i f i t r e C Design life 10 Years 25 77 0 0 5 4 e f i L e l c y C Recommend...

Page 7: ...running ADD Switch 4 ADD switches to definite different baud rate Nether position is OFF means 0 Upper position is ON means 1 0000 setup the baud rate 115200 and 1000 setup the baud rate 9600 Console...

Page 8: ...capacity expanding For each single module each terminal can achieve charging and discharging function For power cables uses water proofed AMPHENOL connectors It must keep pressing this Lock Button du...

Page 9: ...tions flash 1 light 0 25s off 3 75 seconds flash 2 0 5s light 0 5s off flash 3 0 5s light 1 5s off Battery Statues Protect ion Alarm Normal RUN ALM Capacity LED Descriptions Shut Down Off Off Off Off...

Page 10: ...ge Model Charge Discharge Over Current Charge Discharge Current Limit High Low Temperature Capacity Retention Calculate Short Circuit Administrator Monitor Power Cable Reverse Operation Record 3 Safe...

Page 11: ...re exposed metal surfaces of the available tools except their tips with electrical tape 3 4 Safety Gear It is recommended to wear the following safety gear when dealing with the battery pack Insulated...

Page 12: ...ttery package Grounding cable 2 For battery system connects to inverter Two long power cables current capacity 120A and one communication cable for each energy storage system NOTE These three long cab...

Page 13: ...nd humidity is maintained at a constant level There is minimal dust and dirt in the area CAUTION If the ambient temperature is outside the operating range the battery pack stops operating to protect i...

Page 14: ...Put the battery into the cabinet Drive the 4 pcs screws Connect the cables between battery modules Connect the cables to inverter energ a indoor www Latpower com...

Page 15: ...r cable and communication cable 1 Switch power on Switch on all the battery modules and the green LED light below will be on 2 The one with emptyLink Port 0 is the Master Battery Module others are sla...

Page 16: ...to power on all the battery LED light will be on one by one from the Master battery If all the battery LED lights on and then off which means the battery system is good and working C Installation wit...

Page 17: ...energ a indoor www Latpower com...

Page 18: ...Aim at the 4 pare of Location Pin and Location Hole stack the batteries together And hasp the 4 agraffes together energ a indoor www Latpower com...

Page 19: ...Maximum 4 batteries can be athwart stacked One or two batteries can be sidelong stacked Cables connection and batteries system start are same as cabinet installation energ a indoor www Latpower com...

Page 20: ...at means system is abnormal please check values as following a Temperature Above 50 or under 10 the battery could not work Solution to move battery to the normal operating temperature range between 10...

Page 21: ...eyes Rinse eyes with flowing water for 15 minutes and seek medical attention Contact with skin Wash the affected area thoroughly with soap and water and seek medical attention Ingestion Induce vomiti...