8.0 Information about the scales available on the 

Bluelab Conductiviy Pen

EC

Is a measure of electrically charged nutrient ions in a solution and is the only absolute 

measure of conductivity.
Pure water will not conduct electricity. Water usually conducts electricity because it 

is full of impurities, in our case, electrically charged nutrient ions. The two black dots 

on the end of a conductivity probe are called electrodes. When these are placed 

in a solution, an electrical current passes from one electrode, through the water to 

the other electrode and counts the number of electrically charged ions present. This 

represents the units measured - EC.

ppm measures parts per million 

There are many different scales used for different industries around the world and 

for many different reasons! Did you even know there are more than two scales? The 

most widely used scales in Hydroponics are the 500 scale, 650 scale and the 700 scale.

What’s the difference? 

The ppm 500 scale is based on measuring the KCl or potassium chloride content of 

a solution. The ppm 700 is based on measuring the NaCl or sodium chloride content 

of a solution. Individual nutrient ions have different electrical effects! The true ppm of 

a solution can only be determined by a chemical analysis. ppm cannot be accurately 

measured by an EC meter. They are present on Bluelab products as a conversion 

guide only. The conversion is as follows; 
2.4 EC x 500 = 1200 ppm (500 scale) or 1200 ppm / 500 = 2.4 EC 

2.4 EC x 700 = 1680 ppm (700 scale) or 1680 ppm / 700 = 2.4 EC

If you are wanting to measure your solution in ppm, you will need to know the 

following:

•  What ppm scale is your meter using?
•  Which calibration standard should you use for your meter?
•  What ppm scale is my nutrient referring to?

English

7

Bluelab Probe Care Kits

The instrument is only as accurate as the probe 

is clean!

Probe cleaning is one of the most important parts of owning 

and operating any Bluelab meter, monitor or controller.

If the probe is contaminated (dirty) it affects the accuracy of the 

reading displayed.

Bluelab Probe Care Kit range is available for:

•  pH probe care
•  pH & conductivity probe care
•  Conductivity probe care
All the tools you need are included in each kit.
To re-stock your care kit, choose from the 

Bluelab Solutions range.

›  Probe care instructions
›  2x 20ml Bluelab 2.77 EC Standard Solution 

single-use sachets

›  Bluelab Conductivity Probe Cleaner & Chamois
›  Plastic cup

Bluelab Probe Care Kit - 

Conductivity contents: 

Summary of Contents for conductivity pen

Page 1: ... Calibration 5 Error messages 5 Troubleshooting guide 6 Technical specifications 6 Information about the scales available on the Bluelab Conductivity Pen 7 Blulelab Probe Care Kits 7 Bluelab limited warranty 8 Contact details 9 Care and use guide a handy solution made easy bluelab com ...

Page 2: ...g Long press to turn off Calibrate button See calibration section Units button Hold until units flash then short press to change units Screen will change back when no buttons have been pressed for 3 seconds Quick guide Low battery warning Appears when batteries are low Check mark tick to indicate successful calibration ATTENTION The instrument is only as accurate as the probe is clean Shroud The c...

Page 3: ...he power button again To change units Hold down the units button for 3 seconds until the conductivity and temperature units start flashing Short press units button again to cycle between unit combinations To exit this mode don t press anything for 3 seconds NOTE You can change units while in hold mode by holding down the units button Rinse conductivity probe To reduce the build up of nutrient salt...

Page 4: ...is present repeat the cleaning process Replace shroud and test in a known solution to ensure the unit has been adequately cleaned Calibration of the probe is required after every clean See the pH calibration in section 6 0 Place storage cap back onto the probe 3 0 Battery replacement The conductivity pen is powered with 1 x AAA alkaline battery Do not use rechargeable batteries A low battery warni...

Page 5: ...played If Err is displayed check the probe is clean and that the calibration solution is fresh and uncontaminated A check mark will appear on the screen to indicate that the calibration was successful The check mark will disappear after 30 days To reset back to factory default remove replace battery NOTE If you need to test or calibrate in a 1500 ppm solution you MUST set the pen to EC then multip...

Page 6: ...ion Check the table in section 4 0 for what solution to use for your selected conductivity unit Screen does not turn on Replace unit 7 0 Technical specifications Measurement Range 0 0 10 0 EC 0 5000 ppm 500ppm TDS 0 7000 ppm 700 ppm 0 50 C 32 122 F Resolution 0 1 EC 10 ppm 700 10 ppm 500 1 C 1 F Accuracy at 25 C 77 F 0 1 EC 50 ppm 500 ppm 70 ppm 700 ppm 1 C 2 F Temperature compensation Automatic O...

Page 7: ...solution Individual nutrient ions have different electrical effects The true ppm of a solution can only be determined by a chemical analysis ppm cannot be accurately measured by an EC meter They are present on Bluelab products as a conversion guide only The conversion is as follows 2 4 EC x 500 1200 ppm 500 scale or 1200 ppm 500 2 4 EC 2 4 EC x 700 1680 ppm 700 scale or 1680 ppm 700 2 4 EC If you ...

Page 8: ...oduct Product repaired or altered by parties other than Bluelab or its authorised agents Product with defaced missing or illegible serial numbers Products not purchased from Bluelab or a Bluelab authorised distributor or reseller How Do You Get Service To begin a warranty claim you must return the Product to the point of purchase with valid proof of purchase as defined above In California you can ...

Page 9: ...7 578 0847 Email support bluelab com get online Looking for specifications or technical advice Visit us online at bluelab com or facebook com getbluelab To watch instruction videos visit our online video library vimeo com bluelab post Bluelab Corporation Limited 8 Whiore Avenue Tauriko Business Estate Tauranga 3110 New Zealand Instruction Manual English PENCON_V01_210916 Copyright 2015 all rights ...

Reviews: