BlueCard BS-4010 Usage Manual Download Page 4

 

3

Description of the BS-4010M/BS-4010 hardware                                     

 

Status LED Lights 

(in the descriptions below, “up” indicates the direction on the BS-4010 where the 
status LED lights are located): 

-

 

Red LED – Upper-Left 

 

Flashing: communicating over the mobile phone network. 

 

Constant on: the BS-4010 has data that needs to be uploaded. 

 

Constant off: the BS-4010 does not have data that needs to be uploaded. 

-

 

Green LED – Lower-Left 

 

Flashing once per second: the BS-4010 is operating normally. 

-

 

Red LED – Upper-Right 

 

Constant on: the unit is connected with the remote unit via its modem 
module. 

 

Constant off: the unit is not connected with the remote unit via its 
modem module. 

 

-

 

Blue LED – Lower-Right 

 

Flashing once per second: the BS-4010 is operating normally. 

 

Flashing quickly: the BS-4010 is communicating with a guard tour 
reader. 

 

Audio Signals 

There are two types of audio signals: long beep and short beep. 
Some of the audio signals below have multiple meanings depending on the situation. 

-

 

Short Beep (once) 

 

Guard tour reader has been found, but the reader does not contain data 
that needs to be uploaded. 

 

The local unit has connected successfully with the remote unit via the 
phone line. 

-

 

Short Beep (twice consecutively) 

 

The phone line has not been connected properly. 

 

The remote phone number is busy or is not being answered. 

 

Guard tour reader has been found, and the reader contains data that needs 
to be uploaded. 

-

 

Short Beep (three times consecutively) 

 

The BS-4010’s memory is full, please upload to the BS-4010m first. 

 

Phone dialing has been disabled. 

-

 

Long Beep (once)   

 

Data transfer from the reader to the BS-4010 has been completed. 

-

 

Long Beep (three times consecutively) 

 

Data has been completely transferred via the phone line, and the line has 
been disconnected. 

-

 

Long Beep (once) + Short Beep (three times) 

Summary of Contents for BS-4010

Page 1: ...and Phone Line Remote Communication Station Usage Manual BS 4010M BS 4010 Server Comm Station Remote Client Comm Station Please read this manual carefully before starting to operate the station ENGLIS...

Page 2: ...the remote locations to collect data from guard tour readers and upload data to BS 4010M Server located at the main office BS 4010M Server Installed at the main office to receive data from BS 4010 Cl...

Page 3: ...3 AUDIO SIGNALS 3 POWER SOURCE 4 OPERATING INSTRUCTIONS 4 INSTALLING THE SOFTWARE 4 SETTING UP THE DIAL UP NUMBER ON THE BS 4010 CLIENT 4 COLLECTING DATA FROM GUARD TOUR READERS 6 REMOTE DATA UPLOAD...

Page 4: ...rd tour reader Audio Signals There are two types of audio signals long beep and short beep Some of the audio signals below have multiple meanings depending on the situation Short Beep once Guard tour...

Page 5: ...erating correctly Operating Instructions Installing the software Install the guard tour system software Install the software provided for BS 4010 BS 4010M which is named Setup Centre Dial up Number Th...

Page 6: ...0M Server to the local land phone line and make sure the BS 4010 Client at the remote location is also connected to remote land phone line Start the Setup Centre Dial up Number program by double click...

Page 7: ...beeps it means that its memory is full and will need to have it uploaded before being able to collect any more data from readers Remote data upload When the BS 4010 Client contains data that needs to...

Page 8: ...the upper right red LED flashes once without emitting a beeping sound it indicates that no dial up number has been stored in the unit Please first store the dial up number using the BS 4010 setup prog...

Page 9: ...ording or information storage and retrieval systems for any purpose other than the purchaser s personal use without the written permission of Bluecard Software Technology Co Ltd All trademarks mention...

Reviews: