background image

MODEL A-100

 

Peristaltic Injection Pump

Operating Manual

5300 Business Drive

Huntington Beach, CA 92649, USA

Phone:

 714-893-8529     

FAX:

 714-894-9492

E mail:

 [email protected]   

or

   [email protected]

Website:

 www.Blue-White.com

L

R

R

Summary of Contents for FLEXFLO A-100

Page 1: ...staltic Injection Pump Operating Manual 5300 Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com or techsupport blue white com Website www Blue...

Page 2: ...ally best For instance when the unit is used for injecting deodorized chemicals into a ducting system it would be wired to the mail blowers where they would operate together In this case the R P M And...

Page 3: ...conforms to the requirements of NSF standard 50 2 LOCATION WEATHER AND VENTILATION A good solid floor such as concrete or brick is desirable This unit is designed for indoor installations If used out...

Page 4: ...for whatever chemical you are using Do not place the container in direct sunlight Ultraviolet UV rays attack many materials which can cause them to become brittle OPERATION MAINTENANCE Once every wee...

Page 5: ...r water again return pump to service CAUTION do not allow acid and chlorine products to come together This is VERY DANGEROUS to your health OUTPUT ADJUSTMENTS The pause control knob adjusts the cycle...

Page 6: ...e groove of the fitting straight into the slot With the pump running hold the fitting marked L with your left hand your thumb should be covering the L At the same time use your right thumb to guide th...

Page 7: ...30V AC 60HZ 14 RPM A 149 3 230V AC 60HZ 30 45 RPM A 309 3 8 Pump housing 115V 24V A 010 Pump housing 220V 230V A 010J 1 Tube 3 16 O D NORprene A 002 3N Tube 1 4 O D Tygon A 002 4 Tube 1 4 O D NORprene...

Page 8: ...8 DIA Hole only 2 The 1 4 Male N P T fits either requires a Tee a Street ELL of a Saddle Fitting 3 Injector The A 100 is wall or shelf mounted 4 Chemical Tank 5 Stainer 6 Sediment Space NOTE Injector...

Page 9: ...Cap PN 70000 989 9 Suction Tube PN 76000 645 10 Strainer PN C 345S 11 Drain Cap PN 90002 045 12 Sediment Fitting PN 76000 863 SERVICE SUGGESTIONS Success of this system will be the result of care Alwa...

Page 10: ...ased wear on the pump components gears bearings and pump tubes Please follow these steps when cleaning your injection fitting check valves 1 Wash the pump tubing and fittings out with clean water To d...

Page 11: ...ll the Injection Fitting directly into a tee fitting The solution must inject directly into the flow stream Use Teflon thread sealing tape on the pipe threads of the Injection Fitting This illustratio...

Page 12: ...chlorinators they are meant to destroy bacteria and algae contamination before it s removal by filtration Acid and soda injectors are used for pH control balance The injectors are factory tested with...

Reviews: