A-100N
A-100N
4.2
Electrical Connections
Be certain to connect the pump to the proper supply voltage. Using the incorrect voltage will damage
the pump and may result in injury. The voltage requirement is printed on the pump serial label.
Note:
When in doubt regarding your electrical installation, contact a licensed electrician.
The A-100N is supplied with either a ground wire conductor and a grounding type attachment plug
(power cord) or a junction box for field wiring.
POWER CORD MODELS -
To reduce the risk of electric shock, be certain that the power cord is
connected only to a properly grounded, grounding type receptacle.
JUNCTION BOX MODELS -
To reduce the risk of electric shock, be certain that a grounding conduc-
tor is connected to the green grounding conductor located in the junction box.
INPUT
VOLTAGE
115V 60Hz
220V 50Hz
230V 60Hz
HOT
LEADWIRE
YELLOW
YELLOW
YELLOW
NEUTRAL
LEADWIRE
BLUE
BROWN
RED
GROUND
LEADWIRE
GREEN
GREEN
GREEN
FIG. 4.5 WIRING DIAGRAM - DIGITAL TIMER
FIG. 4.6 WIRING DIAGRAM - FIXED TIMERS
FIG. 4.7 WIRING DIAGRAM - LOW FEED “SPA” PERCENTAGE TIMER
FIG. 4.8 WIRING DIAGRAM - VARIABLE SPEED CONTROLLER
T3
Neutral-l2
Hot-l1
Earth
Ground
Output
T2
T1
T4
T5
T6
Motor
Hot (yellow)
Neutral (blue/brown/red)
Common
Hot
Ground
AC
Input
Power
Circuit
Board
2A
250VAC
Protector Fuse
2 Amps, 250 Volt AC
(little Fuse #235002 or Equiv.)
Ground (green)
(factory Setting)
(factory Setting)
Power
Switch
Cycle Adjustment
Potentiometer
T3
T2
T1
AC
Input
Power
Hot
Common
Ground (green)
Timer
Board
Hot
Neutral
AC/LOAD
AC
LOAD
JB2 JB3
JB1
AC
Motor
Page 6
Page 7
Cycle Adjustment
Potentiometer
AC
Input
Power
Hot
Common
Ground (green)
Timer
Board
Hot
Neutral
AC/LOAD
AC
LOAD
JB2 JB3
JB1
AC
Motor
Momentary
By-pass
Switch
T3
T2
T1
Jb1, Jb2, Jb3 = Voltage Selector Jumpers
Jumpers Configuration
Install Jb1 & Jb3, (Jb2 left open) = 115 V AC input
Remove all jumpers (Jb1, Jb2, & Jb3 left open) = 230 V AC input
Jb1, Jb2, Jb3 = Voltage Selector Jumpers
Jumpers Configuration
Install Jb1 & Jb3, (Jb2 left open) = 115 V AC input
Remove all jumpers (Jb1, Jb2, & Jb3 left open) = 230 V AC input
Speed Adjustment
Potentiometer
120 VAC
Input
Power
Hot (yellow)
Common (white)
Red (+)
Min
Max
Black (-)
Controller
Board
DC
Motor
50
K
50