Blue-White industries flexflo A-100N Operating Manual Download Page 2

TABLE OF CONTENTS

SECTION

HEADING

PAGE

1

Introduction

2

2

Specifications

3

3

A-100N Features

3

4

How to install the A-100N

4

4.1

Mounting location

4

4.2

Electrical connections

6

4.3

How to install the tubing and fittings

8

5

How to operate the A-100N

10

5.1

How to adjust the output -Digital Timers

10

5.2

How to adjust the output -Fixed Timers

11

5.3

How to adjust the output -Variable Speed Control

11

6

How to maintain the A-100N

12

6.1

Routine inspection and cleaning

12

6.2

How to clean and lubricate the A-100N

12

6.3

How to replace the pump tube

12

Replacement parts drawing

14

Replacement parts list

15

1.0

Introduction

Congratulations on purchasing the A-100N Peristaltic Metering Pump.  The A-100N is designed to inject 
chemicals into piping systems.  The pump has been tested by NSF International for use with 12 ½% 
Sodium Hypochlorite.  It is available from the factory with five optional feed rate adjustment mecha-
nisms.

1.

Digitally Programmable Cycle Timer -

 The fixed speed pumping mechanism is turned  on and off by 

an electronic timer.  The total-time cycle is adjustable from 1.0 second through 99 seconds.  The on-time 
cycle is adjustable from 0.5 seconds through 99 seconds.  Settings from 0.5 through 9.9 seconds are 
adjustable in 0.1 second increments.

2.

Fixed Cycle Timer -

 The fixed speed pumping mechanism is turned on and off by an electronic timer. 

The  total cycle time is factory set.  The available cycles are 1 minute, 10 minute, 5 second.  The on-time 
cycle is adjustable from 5% through 100% of the total cycle time. A low feed “spa” model is available 
with a 1 minute fixed total cycle with a 6 second maximum on time; ideal for spa and hot tub chlorina-
tion.

3.

Variable Speed Controller - 

The speed of the pumping mechanism is adjustable from 5% through 

100%.

4.

Proportional Feed Input Signal -

 The fixed speed pumping mechanism is turned on and off by Blue-

®

®

White’s DIGI-FLO  Flowmeter (sold separately).  Controls located on the DIGI-FLO  are adjusted to 
regulate the pump strokes per flow rate in the piping system.

5.

Fixed Feed Rate - 

No adjustment control.

A-100N

A-100N

2.0

Specifications

Maximum Working Pressure

100 psig / 6.9 bar*

o o 

Maximum Fluid Temperature

 

130  F / 54 C

o o

Ambient Temperature Range

14 to 110 F / -10 to 43 C

Enclosure

NEMA 3R (acceptable for outdoor use)

Duty Cycle

Continuous

Maximum Solids

50% by volume

Maximum Viscosity

5,000 Centipoise

Maximum Suction Lift

up to 30 ft. water

Power Requirements

115V60Hz  80 Watts

220V50Hz  40 Watts

230V60Hz  45 Watts 

Dimensions

6-1/8” high x 10-1/8” wide x 9” deep

Weight

8 lb.

3.0

A-100N Features

!

Peristaltic Pump Tube does not require valves.

!

High outlet pressure capability of 100 psig.*

!

High inlet suction lift capability of 30 feet.

!

Quick-Disconnect inlet and outlet fittings available. 

!

Digital electronic feed rate control available.

!

Pump Tube failure warning timer (digital models).

!

200:1 adjustment turn down ratio (digital models).

!

Acceptable for outdoor use.

!

Corrosion proof Valox housing.

!

Tamper resistant electronic control panel cover.

!

Easy servicing.

!

Includes suction tube strainer, tube weight, suction tubing, discharge tubing and injection fitting with 
internal back-flow check valve and mounting hardware.

FIG. 3.0 PARTS LOCATOR DRAWING

*

Most models.

**

Slide both top & bottom clamps to the left only far enough  to open the control cover.

L

A IT

U

Y

Q

P

T

R

C

O U

D

RESET

TUBE LIFE WARNING TIMER

PRIME

99 SEC. CYCLE

UP

DOWN

TOTAL

TIME

ON

TIME

ADJUST

CYCLE

WHEN LIT

STANDBY

RECOMMEND TUBE CHANGE WHEN DISPLAY BLINKS

CYCLE TIME

ADJUSTMENT

TOTAL TIME

1 TO 99 SECONDS

ON TIME

.1 TO 99 SECONDS

9

8

3

  Control

Control Cover

Pumphead

Enclosure

Rear Plate

Pumphead
Cover

6.0

Pumptube
Assembly

Rotor
Assembly

9

8

1

  Slide Clamps**

Page 2

Page 3

Summary of Contents for flexflo A-100N

Page 1: ...CTOR PUMP OPERATING MANUAL 5300 Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white net Web site www blue white net INJECTOR BLUE WHITE INDUSTRIES...

Page 2: ...itally Programmable Cycle Timer The fixed speed pumping mechanism is turned on and off by an electronic timer The total time cycle is adjustable from 1 0 second through 99 seconds The on time cycle is...

Page 3: ...control available Pump Tube failure warning timer digital models 200 1 adjustment turn down ratio digital models Acceptable for outdoor use Corrosion proof Valox housing Tamper resistant electronic c...

Page 4: ...he pump tube Do not mount the pump directly over your chemical container Chemical fumes may damage the unit Mount the pump off to the side or at a lower level than the chemical container Mounting the...

Page 5: ...RIME UP C D O U T A I L Y T CYCLE 1 Strainer 7 Injector 2 Circulation Pump Blue White A 100N 3 Filter 8 Solution Tank 4 Heater 9 Injection Fitting 5 Check Valve 10 Return Line 6 Flowmeter Blue White F...

Page 6: ...electric shock be certain that the power cord is connected only to a properly grounded grounding type receptacle JUNCTION BOX MODELS To reduce the risk of electric shock be certain that a grounding co...

Page 7: ...put Power Hot Common Ground green Timer Board Hot Neutral AC LOAD AC LOAD JB2 JB3 JB1 AC Motor Momentary By pass Switch T3 T2 T1 Jb1 Jb2 Jb3 Voltage Selector Jumpers Jumpers Configuration Install Jb1...

Page 8: ...ner Drop the strainer into the solution tank 4 3 3 Outlet Tubing Compression tube models Locate the outlet fitting of the Pump Tube see fig 6 1 Remove the tube nut Push the opaque outlet discharge tub...

Page 9: ...ED VIEW 5 0 How to Operate the A 100N 5 1 How to Adjust The Output Digital Timers fig 5 1 5 1 1 Digital Programmable Timer Model The pumping mechanism is turned on and off by an electronic cycle timer...

Page 10: ...JUST CYCLE WHEN LIT STANDBY RECOMMEND TUBE CHANGE WHEN DISPLAY BLINKS CYCLE TIME ADJUSTMENT TOTAL TIME 1 TO 99 SECONDS ON TIME 1 TO 99 SECONDS SLIDE CLAMP Slide both top bottom clamps to the left only...

Page 11: ...off status depending on the power switch status when the input power was disconnected A 100N 0 100 50 75 I O 25 ON OFF BLUE WHITE INDUSTRIES L A IT U Y Q P T R C O U D PERCENTAGE OF OUTPUT 5 2 2 Fixed...

Page 12: ...the pump head chamber roller assembly and pump head cover should be wiped free of any dirt and debris The pump head cover bearing may require grease periodically Apply a small amount of grease Aerosh...

Page 13: ...the pump head cover 6 3 1 4 With the pump running pull the inlet fitting out of the pumphead Guide the tube counter clockwise away from the rollers Pull the outlet fitting out of the pump head 6 3 2 H...

Page 14: ...NECT OPTIONAL JUNCTION BOX 49 35 36 37 38 39 45 48 47 46 40 42 44 15 16 11 3 14 43 13 31 30 17 26 27 51 50 6 3 2 1 2 9 52 56 5 4 7 8 53 54 55 10 12 28 29 41 25 24 23 22 20 21 19 18 33 32 34 AD JU ST C...

Page 15: ...1 N s 70002 069 Gearmotor V speed 1 60 Rpm 90 Volts Dc 1 Item Part No Description Qty Item Part No Description Qty 18 90006 581 Fan Motor 2 25 Diameter Aluminum 1 19 70000 028 Bearing Bracket With Bea...

Page 16: ...Prepay all shipping costs COD shipments will not be accepted Warranty service must be performed by the factory or an authorized service center Damage caused by improper packaging is the responsibility...

Reviews: