Page 1: ...CTOR PUMP OPERATING MANUAL 5300 Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white net Web site www blue white net INJECTOR BLUE WHITE INDUSTRIES...

Page 2: ...itally Programmable Cycle Timer The fixed speed pumping mechanism is turned on and off by an electronic timer The total time cycle is adjustable from 1 0 second through 99 seconds The on time cycle is...

Page 3: ...control available Pump Tube failure warning timer digital models 200 1 adjustment turn down ratio digital models Acceptable for outdoor use Corrosion proof Valox housing Tamper resistant electronic c...

Page 4: ...he pump tube Do not mount the pump directly over your chemical container Chemical fumes may damage the unit Mount the pump off to the side or at a lower level than the chemical container Mounting the...

Page 5: ...RIME UP C D O U T A I L Y T CYCLE 1 Strainer 7 Injector 2 Circulation Pump Blue White A 100N 3 Filter 8 Solution Tank 4 Heater 9 Injection Fitting 5 Check Valve 10 Return Line 6 Flowmeter Blue White F...

Page 6: ...electric shock be certain that the power cord is connected only to a properly grounded grounding type receptacle JUNCTION BOX MODELS To reduce the risk of electric shock be certain that a grounding co...

Page 7: ...put Power Hot Common Ground green Timer Board Hot Neutral AC LOAD AC LOAD JB2 JB3 JB1 AC Motor Momentary By pass Switch T3 T2 T1 Jb1 Jb2 Jb3 Voltage Selector Jumpers Jumpers Configuration Install Jb1...

Page 8: ...ner Drop the strainer into the solution tank 4 3 3 Outlet Tubing Compression tube models Locate the outlet fitting of the Pump Tube see fig 6 1 Remove the tube nut Push the opaque outlet discharge tub...

Page 9: ...ED VIEW 5 0 How to Operate the A 100N 5 1 How to Adjust The Output Digital Timers fig 5 1 5 1 1 Digital Programmable Timer Model The pumping mechanism is turned on and off by an electronic cycle timer...

Page 10: ...JUST CYCLE WHEN LIT STANDBY RECOMMEND TUBE CHANGE WHEN DISPLAY BLINKS CYCLE TIME ADJUSTMENT TOTAL TIME 1 TO 99 SECONDS ON TIME 1 TO 99 SECONDS SLIDE CLAMP Slide both top bottom clamps to the left only...

Page 11: ...off status depending on the power switch status when the input power was disconnected A 100N 0 100 50 75 I O 25 ON OFF BLUE WHITE INDUSTRIES L A IT U Y Q P T R C O U D PERCENTAGE OF OUTPUT 5 2 2 Fixed...

Page 12: ...the pump head chamber roller assembly and pump head cover should be wiped free of any dirt and debris The pump head cover bearing may require grease periodically Apply a small amount of grease Aerosh...

Page 13: ...the pump head cover 6 3 1 4 With the pump running pull the inlet fitting out of the pumphead Guide the tube counter clockwise away from the rollers Pull the outlet fitting out of the pump head 6 3 2 H...

Page 14: ...NECT OPTIONAL JUNCTION BOX 49 35 36 37 38 39 45 48 47 46 40 42 44 15 16 11 3 14 43 13 31 30 17 26 27 51 50 6 3 2 1 2 9 52 56 5 4 7 8 53 54 55 10 12 28 29 41 25 24 23 22 20 21 19 18 33 32 34 AD JU ST C...

Page 15: ...1 N s 70002 069 Gearmotor V speed 1 60 Rpm 90 Volts Dc 1 Item Part No Description Qty Item Part No Description Qty 18 90006 581 Fan Motor 2 25 Diameter Aluminum 1 19 70000 028 Bearing Bracket With Bea...

Page 16: ...Prepay all shipping costs COD shipments will not be accepted Warranty service must be performed by the factory or an authorized service center Damage caused by improper packaging is the responsibility...