background image

Mechanical seal, complete

Hoses and metal hose clamps

F

.

Resultant Damages

We cannot be responsible for damages to the product if the product is not used in
accordance with the instructions provided.

G

.

Technical Data and Specifications

The recommended filter run time is twice a day for 4 to 5 hours; regular backwashing
time is 2-3 minutes at least once a week, and floor vacuum cleaning as needed are
the basic pump requirement for maintaining clean swimming pool water!

The major components for all models are: (Confirm you have all these components
before starting installation)

The 7-way valve, filter pump, filter tank, 1 1/4’’-1 1/2’’ hose connectors and base

plate.

Model

NE4490 (400-HTA2SP075)

Flow rate:

5040 GPH/2160GPH

Voltage/Frequency:

115V/60Hz

Power

2 Speed 3/4 HP

Amount of Sand:

80lbs

Pool size:

12000 US Gallons

Model

NE4499 (500-HTA2SP100)

Flow rate:

5520 GPH/2200 GPH

Voltage/Frequency:

115V/60Hz

Power

2 Speed 1 HP

Amount of Sand:

150lbs

Pool size:

18000 US Gallons

H

.

Unpacking your filter system

Carefully remove the product and all component parts from the box. Cross reference all
parts in the box with the parts list reference chart to make certain all parts are present
before beginning assembly.
NOTE: Some parts may be located within the filter tank. To access these parts, you must
remove the tank cover.
Refer to *page 11&12 for complete EXPLODED VIEW PARTS DIAGRAMS.

I

.

Power source instructions

1.The Above Ground filter pump system you have purchased is equipped with a

standard electrical cord and plug which should only be connected to a power outlet
protected by a 30 Amp Ground-Fault-Circuit-Interrupter (GFCI) that has been
installed by a professional electrician and adheres to local codes and regulations.

2. To avoid electric shock, power cord extensions should not be used.

J

.

Positioning your filter system

For the operation of this filter system with Above Ground pools, you need a
skimmer installed in your pool. Either an integrated skimmer (built into the pool
wall) or a suspended skimmer (attachment to the pool wall).

The installation area must allow an adequate safety margin to the pool wall.

Page 04

Summary of Contents for FlowXtreme Pro NE4490

Page 1: ...VER 0418 NE4490 NE4499 FlowXtreme Pro Filter System Manual...

Page 2: ...before operating Never change the 7 Position Multi Port Valve while the system is operating ALWAYS unplug the system before changing the control valve Install this product with sufficient safety marg...

Page 3: ...ct information contained in this technical manual If there is any indication that safe operation is no longer possible the device is to be disconnected from the power supply and secured against accide...

Page 4: ...Gallons H Unpacking your filter system Carefully remove the product and all component parts from the box Cross reference all parts in the box with the parts list reference chart to make certain all p...

Page 5: ...l the filter tank to about 1 8 depth with water then up to 3 4 full with 20 Pool Filter Grade silica sand NOTE Installation of sand other than 20 Pool Filter Grade silica sand will NOT function proper...

Page 6: ...kwash process described below Turn off the Motor Pump at the Power Source Attach backwash hose not included to backwash port Place the Multi Port Valve in the 4 Backwash position Turn on the Pump Run...

Page 7: ...causes the sand to separate and lift while releasing trapped debris out the waste port and backwash hose Closed Position 5 Function Cleaning the hair and lint strainer This position stops the flow of...

Page 8: ...8 of tank height of water Cover the water chamber to avoid getting sand inside the riser pipe and laterals Start filter in Backwash mode for about 3 minutes and then for about 1 minute in the rinse m...

Page 9: ...n Check the socket and power cord G F C I or main circuit breaker tripped Switch on the breaker if it is immediately tripped again there is a defect in pump or controls Pump motor defective Replace mo...

Page 10: ...S Installation and Operation Illustration Figures Page 10 1 2 8 6 9 3 4 5 7 a b c d d e f g h i j k...

Page 11: ...PIN 1 3015 NEP4072 NE4490 NE4499 16 RIGHT CLAMP 1 3016 NEP4073 NE4490 NE4499 17 LEFT CLAMP 1 3017 NEP4074 NE4490 NE4499 18 MIDDLE PIPE 1 30184 NEP4095 NE4490 18 LONG PIPE 1 30185 NEP4096 NE4499 19 DI...

Page 12: ...P4191 All DRAIN PLUG O RING HTA008 NEP4192 All 7 O RING HTA009 NEP4193 All 8 SCREW HTA010 NEP4194 All 9 PUMP COVER HTA011 NEP4195 All 10 O RING HTA012 NEP4196 All 11 IMPELLER OF ITEM HTA 075 HTA2SP 07...

Reviews: