SETUP AND WIRING DIAGRAM 

 

 

 

FIGURE 3 

 

SETTING CHARGE VOLTAGE 

 

 

Charge voltage should be set to the battery manufacturers recommendations. The factory setting of 14.0 volts is suitable for most lead-acid chemistry 

batteries and does not typically require adjustment. For a predominately float application a somewhat lower voltage of 13.8 volts may be beneficial in decreasing 
water loss. For a heavily cycling application, a somewhat higher voltage of 14.5V may be beneficial in decreasing charge time and increasing amp-hours delivered. 
The adjustment potentiometer location is shown in Figure 3. With the Charge Status LED blinking indicating that the battery at or near full charge, adjust the charge 
voltage potentiometer to the desired battery charge voltage as displayed on the 2000E digital display. If optional temperature compensation option is installed, 
disable temperature compensation, adjust the charge voltage to the desired 80

°

F value, and then turn temperature compensation back on. 

 

Since charge voltage is calibrated by adjusting actual battery charge voltage as displayed on the 2000E, setting charge voltage therefore requires that the 

battery be at or near full charge so that the unit is actually controlling battery voltage at the charge voltage setpoint. This can sometimes be hard to achieve when 
battery capacity is large compared to available PV charge current. Charge Voltage Calibration Tool P/N 930-0031-01 as described in technical bulletin #100209 
simplifies charge voltage calibration be eliminating the need to have the battery be highly charged. To access this and other technical bulletins, see 

www.blueskyenergyinc.com

.  

 

MAXIMUM POWER VOLTAGE 

 

 

The nominal setting for this adjustment is the difference between the PV panel’s open circuit voltage (V

OC

) and maximum power voltage (V

MP

). These 

voltage values are typically listed on both the PV panel datasheet and on the rating label affixed to each PV panel. This value needs to be set correctly for the 
MPPT system to deliver maximum current boost. The factory setting is 4.4 volts which is the appropriate value for many popular 36 cell PV modules. These 
modules typically list V

OC

 at 

21.4 volts and V

MP

 at 

17.0 volts, which yields; 21.4 volts - 17.0 volts = 4.4 volts. 

 

 OPTIMIZING 

MPPT 

 

 

The combined effects of manufacturing tolerances in the PV panel and wiring resistance in a particular installation can sometimes shift the optimum 

setting. While not required, it is recommended that for maximum MPPT current boost performance this adjustment be fine-tuned following installation. This is 
a one-time setup and does not require seasonal adjustment. Fine tuning is also desirable following installation of additional PV panels or other substantial 
system change. 

 

 

Fine tuning is easily accomplished by slowly adjusting the MPPT adjust potentiometer to obtain maximum Output Charge Current. Adjustment is best 

done in near full sun with a discharged battery and cool ambient temperatures. The red MPPT Active LED above the potentiometer turns on when MPPT is 

The 2000E cannot limit and 
control battery voltage if 
temperature compensation 
is enabled with sensor 
installed reverse polarity. 

 

Output charge current will 
be disabled if temperature 
compensation is enabled 
without sensor installed. 

 

 

 

Summary of Contents for SOLAR BOOST 2000E

Page 1: ...G PHOTOVOLTAIC CHARGE CONTROLLER INSTALLATION AND OPERATION MANUAL THIS MANUAL INCLUDES IMPORTANT SAFETY INSTRUCTIONS FOR MODEL SB2000E SAVE THESE INSTRUCTIONS COVERED UNDER ONE OR MORE OF THE FOLLOWING US PATENTS 6 111 391 Blue Sky Energy Inc 2011 430 0012 H ...

Page 2: ...lectrostatic Handling Precautions 5 Selecting PV Modules 6 Temperature Compensation 6 Battery and PV Wiring 6 Setting Charge Voltage 7 Maximum Power Voltage 7 Optimizing MPPT 7 TROUBLESHOOTING GUIDE 8 SPECIFICATIONS 9 FIVE YEAR LIMITED WARRANTY 9 TABLES AND FIGURES Table 1 Charge Status Indicator 3 Table 2 Maximum Conductor Length 3 Voltage Drop 7 Figure 1 Front Panel and Remote Display Indicators...

Page 3: ...ry or other electrical part that may cause explosion i Remove personal metal items such as rings bracelets and watches when working with a lead acid battery A lead acid battery can produce a short circuit current high enough to weld a ring or the like to metal causing a severe burn j Remove all sources of power photovoltaic and battery before servicing or installing 4 CHARGER LOCATION INSTALLATION...

Page 4: ...ghly accurate displayed voltage may be somewhat higher than actual battery terminal voltage when high charge current is being delivered to the battery This is due to voltage drop in the wires between the 2000E and battery Error during charge can be minimized by using large low resistance wiring The 2000E operates on battery power not PV power A battery must be connected with a minimum voltage of 9...

Page 5: ... should always plan and monitor the process Equalization is essentially a controlled over charge and should only be performed on vented liquid electrolyte lead acid batteries Repeated charge discharge cycles can lead to an imbalance in the specific gravity and state of charge of individual battery cells Equalization brings all battery cells up to the same specific gravity and eliminates electrolyt...

Page 6: ...0 with a discharged battery in near freezing temperatures For a more complete MPPT description see www blueskyenergyinc com INSTALLATION WARNING Read understand and follow the Important Safety Instructions in the beginning of this manual before proceeding This unit must be installed and wired in accordance with National Electrical Code ANSI NFPA 70 Over current protection must be provided external...

Page 7: ...s recommendation Most 12 volt flooded or GEL lead acid chemistry batteries require the 30 0 millivolts C 5 00mV C cell setting NiCd and many lead acid chemistry AGM type batteries require the 20 0 millivolts C 3 33mV C cell setting WARNING Do not attach a sensor or any connections other than Blue Sky Energy battery temperature sensor p n 930 0022 20 to the temperature sensor terminals Be certain t...

Page 8: ... be eliminating the need to have the battery be highly charged To access this and other technical bulletins see www blueskyenergyinc com MAXIMUM POWER VOLTAGE The nominal setting for this adjustment is the difference between the PV panel s open circuit voltage VOC and maximum power voltage VMP These voltage values are typically listed on both the PV panel datasheet and on the rating label affixed ...

Page 9: ...cause battery voltage is at setpoint relays may switch on off This normal and will cause no harm The on off symptom will go away with a slight increase or decrease in battery voltage or load current PV BAT must not connect together external to controller for proper operation Relays click on off rapidly Dip switch 2 off Double check dip switch 2 must always be on Used for factory test only Charge s...

Page 10: ...ct of God f operation or installation contrary to instructions pertaining to the product or g cosmetic aging 4 If BSE s examination of the product determines that the product is not defective the consumer shall be charged a test and evaluation fee of 20 and be responsible for all transportation costs and insurance related to returning the product to the consumer The consumer is ultimately responsi...

Page 11: ...Blue Sky Energy Solar Boost 2000E MOUNTING TEMPLATE Figure 4 ...

Reviews: