23
Gas Conversion and Specifications
NOTE: Ensure pilot burner and thermocouple are
correctly located and pilot burner aligns
with main burner ignition port. (Refer to
figure opposite for correct fitting and
alignment dimensions).
Re-connect gas supply tube to pilot burner.
Refit RH main fire brick.
Refit 2 front fire bricks.
Refit 2 half plate castings - ensure they are
correctly interlocked.
Refit centre casting.
Refit front control panel and control knob.
Low Fire Adjustment
NOTE: Adjust low fire adjustment screw on gas control valve to as
shown in ‘Gas Specifications Tables’ at rear of this section.
1.
Light main burner and check flame size on simmer (LOW) position.
NOTE: 'Low Fire Screw' should be sealed with coloured paint on completion of low fire adjustment.
Low Fire
Screw
Main Burner
Ignition Port
Pilot Burner
Thermocouple
18± 2.0
2± 2.0