7
Installation
3.
Fit gas regulator supplied, into gas supply line as close to appliance as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as shown in ‘Gas Conversion Section’ in this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and
it is NOT to be adjusted.
Regulator connections are
1
/
2
" BSP female.
Connection to appliance is
1
/
2
" BSP male.
(Refer to ‘Specifications’ section for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line.
4.
Correctly locate griddle toaster into its final operating position and using a spirit level, adjust legs so
that appliance is level and at correct height.
5.
Connect gas supply to appliance. A suitable jointing compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
6.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
7.
Check gas operating pressure is as shown in ‘Specifications’ section.
NOTE: Operating pressure to be measured at
manifold pressure test point and with all
burners operating at ‘High Flame’ setting.
8.
Turn ‘Off’ mains gas supply and bleed gas out of
appliance gas lines.
9.
Turn ‘On’ gas supply and appliance.
10. Verify operating pressure remains correct.
Commissioning
1.
Before leaving new installation;
a. Check the following functions in accordance with operating instructions specified in ‘Operation’
section of this manual.
Light the Pilot Burner.
Light the Main Burners.
Check the Low Fire burner operation.
Check the High Fire burner operation.
b. Ensure operator has been instructed in areas of correct lighting, operation, and shutdown
procedure for appliance.
2.
This manual must be kept by the owner for future reference, and a record of
Date of Purchase,
Date of Installation
and
Serial Number of Appliance
recorded and kept with this manual.
(These details can be found on Rating Plate attached to R/H inner side panel (refer to
‘Gas Connection’ section).
NOTE: If for some reason it is not possible to get appliance to operate correctly, shut ‘Off’ gas
supply and contact supplier of this appliance.
Pressure Test Point
Low Fire Adjustment
Fig 2
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning
Summary of Contents for Evolution G55T
Page 20: ......