4
- CE Only:
Appliance Classification
Category:
II
2H3P
(20, 30 / 37).
Flue Type:
A
1.
*
The burner operating pressure is to be measured at the manifold test point with two burners
operating at full setting. The operating pressure is ex-factory set through the appliance
regulator and is not to be adjusted, apart from when carrying out gas conversion, if required.
(Refer to the ‘Gas Conversion’ section for details).
Gas Connection
Gas supply connection point is located at the rear of the appliance, approximately 130 mm from the
right hand side, 35 mm from the rear and 655 mm from the floor and is reached from beneath the
appliance. (Refer to the ‘Dimensions’ section).
Connection is ¾" BSP male thread.
Electrical Supply Requirements
230-240 V a.c, 50 Hz, 1.6A, 1P+N+E.
0.4kW.
Oven Fan Motor - 100W.
Specifications
Natural Gas (G20)
Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Oven
Open Burner
(each)
Griddle
(each 300mm section)
Oven
Heat Input
(nett)
Nominal
6.5 kW
5.5 kW
7.8 kW
6.5 kW
5.5 kW
7.8 kW
Reduced
1.75 kW
1.85 kW
---
1.75 kW
1.95 kW
---
Gas Rate
(nett)
Nominal
0.69 m
3
/hr
0.58 m
3
/hr
0.83 m
3
/hr
0.51 kg/hr
0.43 kg/hr
0.61 kg/hr
Reduced
0.19 m
3
/hr
0.20 m
3
/hr
---
0.14 kg/hr
0.15 kg/hr
---
Supply Pressure
20 mbar
30 / 37 mbar
Operating Pressure
9.5 mbar (*)
26 mbar (*)
Gas Connection
3
/
4
” B.S.P. Male
Summary of Contents for Evolution G54
Page 7: ...5 Dimensions Dimensions G54 Cook Top Options G54D Cook Top Options G54C ...
Page 33: ...31 ...
Page 34: ...32 ...