6
Service Procedures
Revision 1/
©
Moffat Ltd, January 2007
Blue Seal Evolution Series Electric Bratt Pans
16
6.2.2 Selector
Switch
6.2 Replacement
1) Remove control and left front panels (refer
6.1.1, 6.1.2)
2) Lift pan fully up.
3) Remove two screws securing capillary locating
plate and remove capilery.
4) Slide thermostat off rear of selector switch.
5) Transfer wires to the new thermostat.
6) Fit new thermostat and reassemble in reverse
order.
Capillary plate
Figure 6.2.1a
Figure 6.3.1b
Thermostat
1) Remove control panel (refer 6.1.1).
2) Slide thermostat off rear of selector switch.
3) Slide knob off selector switch shaft.
4) Remove two screws securing selector switch to
control panel.
5) Transfer wires to the new selector switch.
6) Fit new selector switch and reassemble in
reverse order.
Figure 6.2.1b
2 screws
6.2.3 Contactors
1) Remove left front and control panel (refer
6.1.1 and 6..2)
2) Transfer wires from old contactor to new
contactor.
3) Remove old contactor from din rail.
4) Fit new contactor and reassemble.
Figure 6.2.3
6.2.1 Thermostat
Contactors