Blue Sea Systems P12 7531 User Manual Download Page 1

P12

User Manual

7531 

and 

7532

BATTERY CHARGER

Read and understand the contents of this User Manual. It contains important safety, handling, and operational instructions for P12 Battery Chargers.
This User Manual describes the product mentioned herein at the time of its publication. Specifications and performance are subject to change at the discretion 
of Blue Sea Systems. To view the most current revision of this publication visit bluesea.com/P12.

Scan for 
additional
product
information

Summary of Contents for P12 7531

Page 1: ...perational instructions for P12 Battery Chargers This User Manual describes the product mentioned herein at the time of its publication Specifications and performance are subject to change at the disc...

Page 2: ...roduct Dimensions and Installation Clearances 6 Included Components 7 Supplies Needed 8 Installation Instructions 9 10 Initial Charger Setup 11 Advanced Charger Setup 12 13 Reset to Manufacturer Defau...

Page 3: ...to property Never charge a frozen battery GROUNDING PRECAUTIONS Marine battery chargers and inverters have two grounding connections one from the AC system and one from the DC system ABYC requires th...

Page 4: ...as not to cause an arc b Be sure area around battery is well ventilated while battery is being charged c Clean battery terminals Be careful to keep corrosion from coming in contact with eyes d Add dis...

Page 5: ...tion charging stage the batteries complete their charging by being topped off This is a less aggressive charging stage than Bulk where the current going into a particular battery bank will significant...

Page 6: ...Charging and Alert indicators Graphic LCD Display Termination insulating cover DC output DC strain relief clamp AC strain relief and insulating cover AC input terminals under cover Mounting holes Clea...

Page 7: ...Example 1 x Group 24 440Ah Maximum Example 4 x Group 31 Conductor Length in feet meters Charger Rating 25A 40A 6 ft 1 83 meters 14 AWG 2 5mm 8 AWG 10mm 10 ft 3 05 meters 12 AWG 4mm 8 AWG 10mm 15 ft 4...

Page 8: ...D 7532 BATTERY CHARGERS Clearance for 12 1 4 M6 mounting hardware 7 80 198mm 11 18 284mm 7 40 188mm 8 46 215mm 4 30 109 1mm 12 94 328 8mm 14 20 TOP Recommended side clearance 1 97 50mm Recommended ove...

Page 9: ...ded torque 5 10 in lb 0 6 1 1 Nm Pan Head Machine Screws M3 5 x 6mm Recommended torque 10 15 in lb 1 0 1 8 Nm DC Strain Relief Clamp Screws M3 x 25mm pan head machine screws Recommended torque 5 10 in...

Page 10: ...uses or circuit breakers to verify like new condition Confirm no discoloration or corrosion exists and circuit breakers will manually trip and reset Check for proper ventilation and that no debris has...

Page 11: ...and the battery negative common bus bar Fuses should be installed at the battery positive connections to prevent battery power from feeding back into a fault in the wiring or in the battery charger Se...

Page 12: ...P12 Battery Charger Remote using dielectric grease Connect to the Remote Display Com port of the charger 2 Connect the Automatic Charging Relay s ACR wire to the ACR Connection port s Optional Install...

Page 13: ...elect button 4 Once the desired battery type is highlighted press the OK button Press the Cancel button to go back Note If User mode is selected batteries will not charge until Absorb and Float voltag...

Page 14: ...maximum amperage is the total available amperage to be supplied among all 3 outputs Selecting an amperage less than the maximum could result in under charging of batteries 5 Press the OK button once...

Page 15: ...lected battery type The default Absorb voltages for each battery type can be seen in Table E above Warning Incorrect Absorb and Float voltages could reduce the life of your batteries Contact your batt...

Page 16: ...Absorption Amps The maximum amount of current that a battery bank can receive while in Absorption and still change to Float If a load is active and drawing more than the designated End Absorption Amp...

Page 17: ...rger will increase all output voltages by the value defined in Battery Tempco For example with the default Battery Tempco set to 30mv C if the temperature sensor reads 26 C then all output voltages wi...

Page 18: ...eries are fully charged by verifying the charger is in Float mode with no active loads 2 Turn off or disconnect all DC devices that are connected to the batteries Disconnect the battery banks not bein...

Page 19: ...You may pause Equalization at any time by pressing the pause button 17 If at any point during Equalization a DC load is applied to the battery being equalized Equalization will stop 18 You may stop Eq...

Page 20: ...o Get Here From the Charger Summary Screen select the Menu button From other screens select the Back button Display Setup The Display Setup allows the user to customize the display settings Options Ad...

Page 21: ...if time is being added or subtracted from the timer If paused the charger is in Float or Standby and the Absorb Timer will remain at its current time Read about Absorb Timers on page 14 Options Selec...

Page 22: ...ee if the Fan Alert Screen appears If the Fan Alert Screen does not appear and the fan seems to be operating correctly then continue to use the battery charger normally If the Fan Alert Screen appears...

Page 23: ...use a different AC power source or contact an electrician to diagnose the problem AC Input Voltage Too High If the input voltage rises above 265V AC the alert screen on the right will appear In this s...

Page 24: ...present in order to share charge between battery banks However due to the P12 Battery Charger s ability to independently optimize charging for each battery bank it is favorable to isolate all battery...

Page 25: ...or wire running from the start key switch to the starter solenoid NOTE Connecting the SI Start Isolation wire to only one of the ML ACR isolation wires will not properly integrate the P12 battery char...

Page 26: ...he product was purchased by the first retail customer 2 The date on which the first retail customer purchases a vessel on which the product was installed Blue Sea Systems will at its sole discretion r...

Page 27: ...oltage and Frequency measurement with alarms 2 AC ELCI Ground Fault Protection 3 AC Source Selection 4 AC Branch Circuit Protection and Switching 5 DC Battery Charger Remote Monitoring and Control 6 D...

Page 28: ...425 Sequoia Drive Bellingham WA 98226 USA p 360 738 8230 p 800 222 7617 USA and Canada Customer Service conductor bluesea com www bluesea com 980025140 Rev 005...

Page 29: ...ilisation des chargeurs de batterie P12 Ce manuel d utilisation d crit le produit mentionn dans ce document au moment de sa publication Les sp cifications et les performances sont sujettes modificatio...

Page 30: ...nsions du produit et d gagements pour l installation 6 Composants inclus 7 Fournitures n cessaires 8 Instructions d installation 9 10 Configuration initiale du chargeur 11 Configuration avanc e du cha...

Page 31: ...rels et mat riels Ne chargez jamais une batterie gel e PR CAUTION DE MISE LA MASSE Les chargeurs de batteries marines et les inverseurs ont deux raccords de mise la masse un provenant du circuit c a e...

Page 32: ...ension pour ne pas causer un arc b S assurer que la zone autour de la batterie est bien a r e pendant la charge de la batterie c Nettoyer les bornes de la batterie Faire attention pour viter tout cont...

Page 33: ...ion constante Dans la phase de charge d absorption les batteries effectuent leur charge en tant remplies Cette phase de charge est moins agressive que la phase Bulk charge initiale dans laquelle le co...

Page 34: ...dicateurs de charge et d alerte Afficheur LCD graphique Couvercle isolant de connexion de sortie Sortie c c trier anti traction c c Dispositif anti traction c a et couvercle isolant Bornes d entr es c...

Page 35: ...x groupe 24 440 Ah maximum Exemple 4 x groupe 31 Longueur de conducteur en pieds m tres Puissance du chargeur 25A 40A 6 pi 1 83 m 14 AWG 2 5 mm 8 AWG 10 mm 10 pi 3 05 m 12 AWG 4 mm 8 AWG 10 mm 15 pi...

Page 36: ...llation P12 CHARGEURS DE BATTERIE 7531 ET 7532 D gagement pour fixations n 12 1 4 M6 7 80 198mm 11 18 284mm 7 40 188mm 8 46 215mm 4 30 109 1mm 12 94 328 8mm 14 20 Sup rieur D gagement sup rieur recomm...

Page 37: ...10 in lb 0 6 1 1 Nm Vis m canique t te cylindrique M3 5 x 6 mm Couple recommand 10 15 in lb 1 0 1 8 Nm Vis d trier anti traction c c Vis m caniques t te cylindrique M3 x 25 mm Couple recommand 5 10 in...

Page 38: ...er que leur tat est comme neuf V rifiez l absence de d coloration ou de corrosion et v rifiez le d clenchement et le r armement manuel des disjoncteurs V rifiez l a ration correcte et assurez vous qu...

Page 39: ...f de la batterie et du n gatif de la batterie Les fusibles doivent tre install s au niveau des bornes positives de la batterie pour viter l alimentation de la batterie de provoquer un d faut dans le c...

Page 40: ...batterie l arri re de la t l commande du chargeur de batterie en utilisant de la graisse di lectrique Branchez le l orifice Remote Display Com du chargeur 2 Branchez le c ble du des relais de charge a...

Page 41: ...elect 4 Une fois le type de batterie d sir mis en vidence appuyez sur le bouton OK Appuyez sur le bouton Cancel pour revenir en arri re Note Si le mode Utilisateur est s lectionn les batteries ne se c...

Page 42: ...tale disponible qui doit tre fournie entre les 3 sorties La s lection d une intensit inf rieure au maximum peut entra ner une charge insuffisante des batteries 5 Appuyez sur le bouton OK une fois que...

Page 43: ...absorption par d faut pour chaque type de batterie peuvent tre v rifi es dans le Tableau E ci dessus Avertissement Des tensions d absorption et d entretien incorrectes peuvent r duire la dur e de vie...

Page 44: ...um de courant qu un groupe de batteries peut recevoir pendant la phase d absorption en passant quand m me en phase Float Si une charge est active et absorbe plus que l intensit de fin d absorption pre...

Page 45: ...dans Compensation de temp rature de batterie Par exemple quand la compensation de temp rature de batterie par d faut est r gl e sur 30 mv C si le capteur de temp rature rel ve 26 C toutes les tension...

Page 46: ...n v rifiant que le chargeur est en phase Float entretien sans aucune charge active 2 D sactivez ou d branchez tous les dispositifs c c qui sont branch s aux batteries D branchez les groupes de batteri...

Page 47: ...dure d galisation 16 Vous pouvez interrompre l galisation tout moment en appuyant sur le bouton pause 17 Si tout moment pendant l galisation une charge c c est appliqu e la batterie en cours d galisat...

Page 48: ...rger Summary s lectionnez le bouton Menu partir d autres crans s lectionnez le bouton Back Configuration de l affichage L cran Display Setup permet l utilisateur de personnaliser les param tres d affi...

Page 49: ...t e ou soustraite du temporisateur S il est sur pause le chargeur est en mode Float ou Standby et le temporisateur d absorption reste sa dur e actuelle Les temporisateurs d absorption sont d crits la...

Page 50: ...alerte de ventilateur s affiche Si l cran d alerte de ventilateur ne s affiche pas et que le ventilateur semble fonctionner correctement continuez utiliser le chargeur de batterie normalement Si l cra...

Page 51: ...entation c a diff rente ou contactez un lectricien pour diagnostiquer le probl me Tension d entr e c a trop lev e Si la tension d entr e augmente au del de 265 Vc a l cran d alerte sur la droite s aff...

Page 52: ...dant en raison de la capacit du chargeur de batterie P12 d optimiser la charge ind pendamment pour chaque groupe de batteries il est utile d isoler tous les groupes de batteries en d sactivant la capa...

Page 53: ...de d marreur NOTE Le branchement du fil SI isolement au d marrage un seul des c bles d isolement ML ACR ne permet pas l int gration correcte du chargeur de batterie P12 avec le ML ACR 3 Branchez un c...

Page 54: ...gnifie 1 La date laquelle le produit a t achet par le premier client au d tail 2 La date laquelle le premier client au d tail ach te un bateau sur lequel le produit a t install Blue Sea Systems sa seu...

Page 55: ...nsit c a de tension et de fr quence avec alarmes 2 Protection de d faut la masse c a ELCI 3 S lection de source c a 4 Protection et commutation de circuit c c 5 Contr le et commande distance de charge...

Page 56: ...425 Sequoia Drive Bellingham WA 98226 USA T l 360 738 8230 T l 800 222 7617 Service client tats Unis et Canada conductor bluesea com www bluesea com 980025140 R v 005...

Reviews: