Troubleshooting

Problem

Possible Cause

Prevention/Cure

Burner will not light using igniter

LP gas tank valve is closed

Make sure regulator is securely attached to the LP gas tank per “Installing LP 
Gas Tank,” then turn LP gas tank valve to “OPEN”

LP gas tank is low or empty

Exchange, refill or replace LP gas tank

LP gas leak

1 .  Turn LP gas tank valve to “CLOSED”
2 .  Wait 5 minutes for gas to clear
3 .  Follow “Checking for Leaks” section

Battery needs to be changed

Replace the “AA” battery (follow assembly step for inserting battery)

Electrode and burners are wet

Wipe dry with cloth

Electrode cracked or broken - sparks at crack

Replacement part(s) may be needed - contact Customer Care at 800 .762 .1142

Wire loose or disconnected

Reconnect wire or replacement part(s) may be needed - contact Customer Care 
at 800 .762 .1142

Wire is shorting (sparking) between igniter and electrode Replacement part(s) may be needed - contact Customer Care at 800 .762 .1142

Thermocouple is not operating correctly

1 .  Disconnect LP Gas tank per “Disconnect LP Gas Tank” section .
2 .  Clean area around thermocouple .
3 .  Connect LP gas tank per “Connect LP Gas Tank” section .
4 .  Relight per “Lighting” section .
5 .  If the outdoor fire table is still not working, please contact Customer Care at 

800 .762 .1142 for additional assistance .

Bad igniter

Replacement part(s) may be needed - contact Customer Care at 800 .762 .1142

Burner will not light with match

No gas flow

Check if LP gas tank is empty

a .  If empty, exchange, refill or replace LP gas tank
b .  If LP gas tank is not empty, refer to “Sudden drop in gas flow or 

reduced flame height” (see below)

LP gas tank is low or empty

Exchange, refill or replace LP gas tank

LP gas leak

1 .  Turn LP gas tank valve to “CLOSED”
2 .  Wait 5 minutes for gas to clear
3 .  Follow “Checking for Leaks” section

Coupling nut and regulator not fully connected

Turn the coupling nut about one-half to three-quarters additional turn until solid 
stop . 

Tighten by hand only - do NOT use tools.

Obstruction of gas flow

1 .  Clear burner/venturi tube
2 .  Check for bent or kinked hose

Disengagement of burner to valve

Re-engage burner and valve

Spider webs or insect nest in burner/venturi tube

Clean burner/venturi tube

Thermocouple is not operating correctly

1 .  Disconnect LP Gas tank per “Disconnect LP Gas Tank” section .
2 .  Clean area around thermocouple .
3 .  Connect LP gas tank per “Connect LP Gas Tank” section .
4 .  Relight per “Lighting” section .
5 .  If the outdoor fire table is still not working, please contact Customer Care at 

800 .762 .1142 for additional assistance .

Burner ports clogged or blocked

Clean burner ports

Sudden drop in gas flow or reduced flame height

Out of gas

Exchange, refill or replace LP gas tank

Overfilling prevention device may have been activated

1 .  Turn control knob to “  OFF”
2 .  Wait 30 seconds and light outdoor fire table per “Lighting” section
3 .   If flames are still too low, reset the overfilling prevention device:

a .  Turn control knob(s) “  OFF”
b .  Turn LP gas tank valve to “CLOSED”
c .  Disconnect regulator
d .  Turn control knobs to   (HIGH)
e .  Wait one minute
f .  Turn control knobs to “  OFF”
g .  Reconnect regulator and leak check connections, being careful not to 

fully open valve

h .  Light outdoor fire table per “Lighting” section

Irregular flame pattern, flame does not run the 
full length of burner

Burner ports are clogged or blocked

Clean burner ports

Flame is yellow or orange

New burner may have residual manufacturing oils

Burn outdoor fire table for 15 minutes and reinspect

Spider webs or insect nest in burner/venturi tube

Clean burner/venturi tube

Poor alignment of valve to burner/venturi tube

Ensure burner/venturi tube is properly engaged with valve

Flame goes out

High or gusting winds

Do not use outdoor fire table in high winds

Low on LP gas

Exchange, refill or replace LP gas tank

Excess flow valve tripped

Refer to “Sudden drop in gas flow or reduced flame height”

Thermocouple is not operating correctly

1 .  Disconnect LP Gas tank per “Disconnect LP Gas Tank” section .
2 .  Clean area around thermocouple .
3 .  Connect LP gas tank per “Connect LP Gas Tank” section .
4 .  Relight per “Lighting” section .
5 .  If the outdoor fire table is still not working, please contact Customer Care at 

800 .762 .1142 for additional assistance .

Flashback (fire in venturi/burner tube(s))

Burner and/or burner/venturi tube is blocked

Clean burner and/or burner/venturi tube

Flame seems to lose heat when burning in cold 
weather - temperature below 50ºF

Ice has built up on the outside of the LP gas tank 
because the vaporization process is too slow

1 .  Turn off per “Turning Off” section
2 .  Replace with a spare LP gas tank
3 .  Reconnect LP gas tank per “Installing LP Gas Tank” section
4 .  Follow “Checking for Leaks” section
5 .  Light outdoor fire table per “Lighting” section

For assistance, please visit us at BlueRhino.com or call 1.800.762.1142.

Summary of Contents for GAD17300B

Page 1: ...00B Available at Need Propane Table of Contents Important Safeguards Page 2 Expanded View and Hardware 4 Assembly Instructions 5 Installing LP Gas Tank 8 Operating Instructions 9 Cleaning and Care 9 Product Registration 10 Replacement Parts 10 Limited Warranty 10 Troubleshooting 11 The use and installation of this product must conform to local codes In absence of local codes use the latest edition...

Page 2: ...Do NOT store a spare LP gas tank under or near this appliance m Never fill the cylinder beyond 80 percent full n A fire causing serious injury or damage to property may occur if the above is not followed exactly W W Your outdoor fireplace has been checked at all factory connections for leaks Recheck all connections as described in the Operating Instructions section as shipping can loosen connectio...

Page 3: ...service person Depending on amount of use more frequent cleaning may be required Do NOT operate until all parts have been repaired or replaced W W Use only the regulator and hose assembly provided Use only the replacement regulator and hose assembly specified by Blue Rhino Global Sourcing Inc W W Use only Blue Rhino Global Sourcing Inc factory authorized parts The use of any part that is not facto...

Page 4: ...3 809 18 LP Gas Tank Support 58 23 810 19 LP Gas Tank Bolt 58 23 149 20 Cover 58 23 811 21 Glass Rocks not required and sold separately Pre assembled W W CAUTION Use only Blue Rhino Global Sourcing Inc factory authorized glass rock lava rock The use of any glass rock lava rock that is not factory authorized can be dangerous and will void your warranty Expanded View 1 Hardware A Screw M6x12 Black N...

Page 5: ... back and fully tighten all hardware Be careful not to over tighten That could damage surfaces or strip threads 4 For best results complete each step in the order presented To complete assembly you will need 1 Leak detection solution instructions on how to make the solution are included in the Operating Instructions section of this manual 1 Precision filled LP gas grill tank with Acme Type 1 exter...

Page 6: ...ired for this step W W CAUTION Place mantel on one side of the mantel frame first Do NOT drop mantel onto the frame lower gently by supporting it from beneath W W CAUTION DO NOT drop mantel on mantel frame Lower mantel by supporting mantel from under the mantel frame 5 Attach LP Gas Tank Support B x 4 6 Attach Rear Panel C x 4 ...

Page 7: ...he use of any lava rock that is not factory authorized can be dangerous and will void your warranty W W CAUTION Do NOT cover igniter cover Note Lava rocks should be 0 8 2 0 in 2 5 cm long Approx 6 lbs 2 7 kg of lava rocks are needed 8 Place Door 10 Place Table Insert W W WARNING NEVER light the burner with the table insert on the outdoor fireplace W W CAUTION Wait until the outdoor fireplace is co...

Page 8: ... it stops 4 Perform leak check per Checking for Leaks section Disconnecting LP Gas Tank 1 Make sure the control knob is in the OFF position Figure 3 2 Before disconnecting make sure the LP gas tank valve is CLOSED 3 Disconnect regulator hose assembly from LP gas tank by turning knob counterclockwise until it is loose W W CAUTION LP gas tank must be properly disconnected and removed prior to moving...

Page 9: ...Tube LP Gas Valve with Orifice Burner Venturi Pipe Figure 2 X X X X X Figure 3 OFF APAGADO Figure 4 Figure 5 11 8 in 19 7 in 30 50 cm 11 Wait 5 minutes fan with a newspaper or magazine and repeat lighting procedure 12 If igniter does not light burner a Wearing heat resistant gloves position a long lit match or long lit butane lighter near the igniter cover b Push and turn control knob to LOW c Rem...

Page 10: ...dent abuse misuse alteration misapplication improper installation or improper maintenance or service by you or any third party or failure to perform normal and routine maintenance on the product as set out in this owner s manual In addition the Limited Warranty does not cover damage to the finish such as scratches dents discoloration rust or other weather damage after purchase This Limited Warrant...

Page 11: ...ank per Disconnect LP Gas Tank section 2 Clean area around thermocouple 3 Connect LP gas tank per Connect LP Gas Tank section 4 Relight per Lighting section 5 If the outdoor fire table is still not working please contact Customer Care at 800 762 1142 for additional assistance Burner ports clogged or blocked Clean burner ports Sudden drop in gas flow or reduced flame height Out of gas Exchange refi...

Page 12: ...do de carbono el cual no emite ningún olor Usarlo en espacios cerrados puede causar la muerte Nunca use este producto en un espacio cerrado tal como un campero una carpa o en su casa PELIGRO ADVERTENCIA PARA SU SEGURIDAD Solamente para uso en exteriores fuera de cualquier recinto No usar para cocinar ADVERTENCIA PARA SU SEGURIDAD W W Si no se siguen exactamente las instrucciones descritas en este ...

Page 13: ...y causar una fuga Una fuga de gas propano puede resultar en explosión incendio lesiones personales graves o la muerte j No ponga nunca un tanque de gas propano lleno en un carro o camioneta calientes El calor podría hacer que la presión del gas aumentase lo que abriría la válvula de seguridad y haría que se escapase el gas k Ponga la tapa contra el polvo en la válvula de salida del tanque cuando n...

Page 14: ...es mientras esté encendida Deje que la chimenea para exteriores se enfríe antes de moverla o guardarla W W Esta chimenea para exteriores debe limpiarse y verificarse completamente de manera regular Limpie y revise la manguera antes de cada uso del aparato Si detecta alguna señal de abrasión desgaste cortes o fugas deberá sustituir la manguera antes poner en marcha el aparato W W Esta chimenea para...

Page 15: ... del tanque a gas propano 58 23 810 19 Perno de sujeción del tanque de propano 58 23 149 20 Cubierta de la chimenea para exteriores 58 23 811 21 Piedras de vidrio no se requieren y se venden por separado Viene ensamblado W W PRECAUCIÓN Use únicamente rocas de lava o vidrio autorizadas de fábrica de Blue Rhino Global Sourcing Inc El uso de rocas de lava o vidrio no autorizadas por la fábrica puede ...

Page 16: ...ma manual Luego después de completar cada paso ajústelos por completo Tenga cuidado de no ajustar demasiado Se podrían dañar las superficies o forzar las roscas 5 Para obtener mejores resultados siga todos los pasos en el orden indicado Para terminar el armado de la unidad necesitará una 1 solución para detección de fugas Las instrucciones sobre cómo preparar esta solución se encuentran en la secc...

Page 17: ...ero C x 4 7 Coloque la placa del hogar W W PRECAUCIÓN Se necesitan dos 2 personas para realizar este paso W W PRECAUCIÓN Primero coloque el hogar sobre uno de los lados del marco del hogar NO deje caer el hogar sobre el marco sino desciéndalo cuidadosamente sujetándolo desde abajo W W PRECAUCIÓN NO deje caer el hogar sobre su marco Descienda el hogar sujetándolo desde abajo de su marco ...

Page 18: ...e vidrio no autorizadas por la fábrica puede ser peligroso Su uso invalidará su garantía W W PRECAUCIÓN NO cubra el cubierta del encendedor Nota Las rocas de lava deben medir entre 0 8 y 2 0 pulg 2 5 cm de largo Se necesita aproximadamente 2 7 kg 6 lb de rocas de lava 8 Acople la puerta 10 Coloque la tapa de la mesa W W ADVERTENCIA NUNCA coloque la tapa de la mesa sobre la chimenea para exteriores...

Page 19: ...loj hasta su límite 4 Asegúrese de que no haya fugas siguiendo las instrucciones de la sección Detección de fugas Desconectar el tanque de gas propano líquido 1 La perilla de control tiene que estar en la posición APAGADO Vea la Figura 3 2 Antes de desconectar el tanque asegúrese de que la válvula del tanque de gas propano líquido está en la posición CLOSED cerrado 3 Desconecte el regulador y su m...

Page 20: ...rocas de lava alejándolas de la cubierta del encendedor Vea la Figura 4 5 Conecte el tanque de gas propano líquido siguiendo las instrucciones descritas en la sección Instalar el tanque de gas propano líquido del manual del usuario 6 Coloque la válvula del tanque de gas propano líquido en la posición OPEN abierto 7 Oprima y gire la perilla de control a la posición ALTO Continúe manteniendo en posi...

Page 21: ...cíficos y el comprador puede tener otros derechos según el lugar donde el comprador o la compradora residan Ciertas jurisdicciones no permiten limitaciones en cuanto a la duración de una garantía implícita de manera que esta limitación puede no ser aplicable a usted Blue Rhino no autoriza a ninguna persona o compañía para asumir por Blue Rhino cualquier otra obligación a responsabilidad relacionad...

Page 22: ... cerrado 2 Espere 5 minutos para que se disperse el gas 3 Siga las indicaciones de Detección de fugas descritas en el manual del usuario La tuerca de acoplamiento no está conectada por completo Gire la tuerca de acoplamiento entre media vuelta y tres cuartos de vuelta hasta que haga tope con firmeza Apriete únicamente a mano SIN utilizar ninguna herramienta Obstrucción del flujo de gas 1 Limpie lo...

Page 23: ...ions du paragraphe Pour allumer 5 Si le foyer d extérieur en fonctionne toujours pas veuillez contacter le Service à la clientèle au 1 800 762 1142 pour que l on vous aide Fogonazo fuego dentro del venturi tubo s del quremador El quemador y o el tubo venturi del quemador está Bloqueado Limpie el tubo venturi del quemador La llama pierde calor cuando la temperatura exterior baja debajo de 50ºF 10ºC...

Page 24: ... Necesita ayuda Llame al 1 800 762 1142 No vuelva al lugar de compra Para piezas de repuesto 1 800 762 1142 13 ...

Reviews: