User Manual
Tel: +0086-023-67628702 Email:[email protected]
www.cqbluejay.com
Add: Block 3A-13-25, No.153 Jingyu Avenue, Jiangbei Qu, Chongqing City 401147
PART 4. Front panel introduce
LED indicator
Item
Panel
Full name
Definition
1
BEEP
BEEP button
1.
When the buzzer sounds, press and hold for 1~2 seconds to
turn off the buzzer
2.
When the alarm is on and the buzzer is off, press BEEP Button
for 1-2 seconds to turn on the buzzer
2
PAGE
Page button
1.
For LCD screen up and down
2.
There are three pages on the LCD screen and each page
shows two lines of content
First page:
Output voltage: XXX.X Vac
Load ratio: XXX %
Second page:
DC input: XXX.X Vdc
AC input: XXX.X Vac
Third page:
Load power: XX.XX kW
Output frequency: XX.X Hz
3
BLA
Backlight button
Press the backlight key(BLA), the backlight is on
4
LIN
AC City Power indicator
The LIN Indicator ON Mean the inverter work in AC input and ac
output in bypass mode
5
INV
Invert indicator
The INV Indicator ON Means the inverter work in DC input
6
BAT
Battery indicator
The BAT Indicator ON When the battery or DC input voltage is out
the working range of the inverter
7
LAD
Load indicator
The LAD Indicator ON when the inverter fail to work