WIRING DESCRIPTION
Auto Power (Orange Wire) — System Power In (Can be supplied on either the Auto or Manual wire): If power is supplied to the Auto wire, the BG-One
mode of operation will control the voltage on the Bilge Pump Power (Brown Wire). Supports 12 or 24 Vdc power system.
Manual Power (Red Wire) — System Power In (Can be supplied on either the Auto or Manual wire): If power is supplied to the Manual wire, the BG-One
will energize the Pump Power (Brown Wire). Supports 12 or 24 Vdc power system.
Bilge Pump Power (Brown Wire) — Pump Power Output: Connect to Bilge Pump power. Note: The voltage supplied on this line is the same as the voltage
provided into the BG-One on the Auto or Manual Power line. Max current sourced is 20 amps.
Alarm (Yellow Wire) — Alarm Output: Transitions from 0 Vdc to the voltage supplied on the Auto or Manual lines when oil is detected in Mode A (Marina),
Mode B (Marine Sanctuary), and Standard Mode (High Seas). The output supplies up to 1 amp current. Be careful not to connect devices that have a high
inrush current that exceeds 1 amp or permanent damage to the unit may occur.
Ground (Black Wire) — Ground Return: Connect to system ground per Blue Guard Installation Guide.
MAINTENANCE
Periodically check the base of the unit to ensure that no foreign material is stuck inside the sensor portion of the unit.
If salt has built up on the sensor portion, rinse with fresh water to clean.
When oil is detected in the bilge, the leak should be repaired and the bilge should be cleared of oil as a part of practicing prudent seamanship. After the
user of the boat has cleared the bilge of oil, the bottom of the BG-One’s sensor should be wiped with a soft clean cloth to remove the oil or fuel residue. If
any further cleaning is required, use rubbing alcohol followed by wiping with a soft clean cloth.
FCC & IC STATEMENT
Federal Communications Commission Statement
You are cautioned that changes or modifications not expressly approved by the part responsible for
compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: 1. This device may not cause harmful interference and 2. This device must accept any
interference received, including interference that may cause undesired operation of the device.
FCC RF Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environ-
ment. End users must follow the specific operating instructions for satisfying RF exposure limits.
This transmitter must not be colocated or operating with any other antenna or transmitter.
Industry Canada (IC)
This device complies with Industry Canada licence-exempt RSS standards. Operation is subject to
the following two conditions: 1. This device may not cause interference, and 2. This device must
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio ex-
empts de licence L’exploitation est autorisée aux deux conditions suivantes: 1. l’appareil ne doit pas
produire de brouillage, et 2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
IC RF Radiation Exposure Statement
To comply with IC RF exposure requirements, this device and its antenna must not be co-located or
operating in conjunction with any other antenna or transmitter.
Pour se conformer aux exigences de conformité RF canadienne l’exposition, cet appareil et son
antenne ne doivent pas étre co-localisés ou fonctionnant en conjonction avec une autre antenne
ou transmetteur.
WARRANTY INFORMATION
Blue Guard Innovations, LLC 4909 Nautilus Ct N, Suite 121 Boulder, Colorado 80301 warrants
to the original consumer purchaser that this product will be free from defects in material and
workmanship, providing that the unit is not opened or otherwise abused for a period of three (3)
years from the date originally purchased unless otherwise noted or sold by the manufacturer. The
exclusive remedy of the consumer purchaser in the event the product is defective is to return the
product to Blue Guard Innovations, LLC at the above address, freight prepaid with original sales
receipt. IMPORTANT: FOR THIS WARRANTY TO BE EFFECTIVE, the product MUST BE SUPPLIED
WITH PROOF OF ORIGINAL PURCHASE DATE OF THE PRODUCT. THE ACCEPTANCE BY BLUE
GUARD INNOVATIONS, LLC OF ANY PRODUCT RETURNED SHALL NOT BE DEEMED AN
ADMISSION THAT SUCH PRODUCT IS DEFECTIVE OR IN VIOLATION OF ANY WARRANTY. THE
COMPANY RESERVES THE RIGHT TO REPAIR OR REPLACE THE PRODUCT. NO REPRESEN-
TATIVE OR OTHER PERSON IS AUTHORIZED TO ASSUME FOR BLUE GUARD INNOVATIONS,
LLC ANY ADDITIONAL LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS OR TO
ALTER THIS WARRANTY IN ANY WAY. IN NO EVENT WILL BLUE GUARD INNOVATIONS, LLC BE
LIABLE FOR MORE THAN THE SALES PRICE OF THE PRODUCT. UNDER NO CIRCUMSTANCES
WILL BLUE GUARD INNOVATIONS, LLC BE LIABLE FOR ANY LOST PROFITS, INCIDENTAL OR
CONSEQUENTIAL COSTS, EXPENSES, OR DAMAGES. THE LIMITATION ON LIABILITY FOR LOST
PROFITS, INCIDENTAL OR CONSEQUENTIAL COST EXPENSES OR DAMAGES SHALL SURVIVE
ANY FAILURE OF ESSENTIAL PURPOSE OF THIS LIMITED WARRANTY. All wiring on the vessel
shall be performed by a QUALIFIED MARINE ELECTRICIAN and in accordance with the “Fire
Protection Standard for Motor Craft”, NFPA No. 302. The Standards of the American Boat and Yacht
Council, Inc., and the USCG Safety Standards for Boat Electrical Systems (33 CFR 183). Some states
do not allow the exclusive or limitation of incidental or consequential damages, so the above limita-
tion may not apply to you. NO EXPRESS OR LIMITED WARRANTY, INCLUDING WARRANTY OF
MERCHANTABILITY AND FITNESS SHALL EXTEND FOR ANY PERIOD OF TIME GREATER THAN
THREE (3) YEARS FROM THE DATE OF ORIGINAL PURCHASE OF THIS PRODUCT. Some states
do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply
to you. CAUTION - Warranty void if seal on product is broken or product is tampered with in any
way, if any electric cord is cut back more than 4 inches, if electric splices become submerged, or if
product is installed contrary to instructions or warnings. Blue Guard Innovations, LLC 4909 Nautilus
Ct N, Suite 121 Boulder, Colorado 80301.
OIL DETECTION SENSITIVITY & PUMP RUN TIME
Set low, medium, or high oil detection sensitivity via the BGI Config App. Set the pump run time after water and oil detection via the BGI Config App.
Set BG-One Switch Pump Run Time*
After Water Detection Event (Normal) — Set pump run time (15-60 seconds). Factory default is 15 seconds.
After Oil Detection Event — Set pump run time after oil detection (3-15 seconds). Factory default is 3 seconds.
*After water is detected or water is detected for five seconds after oil is detected, the pump will be activated. The pump timer set above will start when the sensor detects air during pump activation. As long
as the One is sensing water, the switch/pump will be on.
www.bluebgi.com