background image

3

 

 

Attention Owners and Operators 

 

The equipment is designed to provide safe and productive processing, cooking and warming of food products 
as long as the equipment is used in accordance with the instructions in this manual and is properly maintained.   
Unless the operator is adequately trained and supervised there is a possibility of serious injury. Owners of this 
equipment bear the responsibility to make certain that this equipment is used properly and safely, and to 
strictly follow all of the instructions contained in this manual and the requirements of local, state or federal law. 

Owners should not permit anyone to touch this equipment unless they are over 18 years old, are adequately 
trained and supervised, and have read and understood this manual. Do not attempt to repair or convert any 
gas types on your own. Repairs and conversions are to be made solely by an authorized local servicer. 
Owners should also ensure that no customers, visitors or other unauthorized personnel come in contact with 
this equipment. Please remember that supplier cannot anticipate every circumstance or environment in which 
its equipment will be operated.    It is the responsibility of the owner and the operator to remain alert to any 
hazards posed by the function of this equipment. If you are ever uncertain about a particular task or the proper 
method of operating this equipment, ask your supervisor. 

This manual contains a number of precautions to follow to help promote safe use of this equipment.   
Throughout the manual you will see additional warnings to help alert you to potential hazards. 

Warnings affecting your personal safety indicated by:

 

 

Warnings affecting your possible damage to the equipment and property are indicated by:

 

 

If any warning labels or this manual are misplaced, damaged, or illegible, or if you require additional copies, 
please contact your nearest representative or vender directly for these items at no charge. 

Please remember that this manual or the warning labels do not replace the need to be alert, 
to properly train and supervise operators, and to use sense when using this equipment. 

 
Please remember that this manual or the warning labels do not replace the need to be alert, 
to properly train and supervise operators, and to use sense when using this equipment. 

 
 
 
 
 
 

Model

 

GAS 

Number Of Burners 

 

BTU/hr Input Rating 

 

12”-2 burners

 

Natural 

50,000 

24”-4 burners

 

Natural 

100,000 

36”-6 burners

 

Natural 

150,000 

Summary of Contents for BFHP-12-2

Page 1: ...lame 223 W Rosecrans Ave GardenaCA 90248USA Tel 1 866 677 8500 1310 808 0102 Fax 1310 808 0242 1310 808 0262 WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICEOR MAINTENANCECANCAUSEPROPERTYDA...

Page 2: ...manual contains important safety instructions which must be strictly followed when using this equipment Please retain this manual for future reference Index ATTENTION OWNERS AND OPERATORS 3 UNPACKING...

Page 3: ...ch its equipment will be operated It is the responsibility of the owner and the operator to remain alert to any hazards posed by the function of this equipment If you are ever uncertain about a partic...

Page 4: ...upply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa These models are designed built and sold for commercial use only Instructions must be posted...

Page 5: ...ountertop lines Do not slide unit with legs mounted lift if necessary to move unit 7 The supplied gas pressure regulator is factory set at 4 Natural gas W C or 10 for L P 8 THESE UNITS ARE SUITABLE FO...

Page 6: ...Always turn off the unit when not in use servicing or adjusting any parts or attachments and before cleaning Never leave the hot plate on overnight Do not operate any equipment with a damaged or leak...

Page 7: ...ocated in the front panel are pilot valve adjustments Use a screwdriver to turn the valve to adjust the flame height to your desired level Igniting the Burner To ignite the burner turn knob to the ON...

Page 8: ...the hot plate Wipe the polished areas with a soft cloth Daily Controls Unit should be turned off when not in use It is recommended that the unit be disconnected from the gas supply by closing the mai...

Page 9: ...in gas line leak Turn off main gas valve DO NOT LIGHT FLAME ignite anything or turn switch on anything electrical Call fire department if needed and call for service Cooking surface is heating up slow...

Page 10: ...are for conversion from Natural Gas to Propane L P on all models The conversion should be done before connecting the unit to the gas supply Units are shipped from the factory equipped for use on natur...

Page 11: ...11 6 Continue with installation L P Position of insert Regulator is now converted to L P...

Page 12: ...L OR CONSEQUENTIAL DAMAGES TO BUYER OR ANY THIRD PARTY INCLUDING WITHOUT LIMITATION LOSS OF PROPERTY PERSONAL INJURY LOSS OF BUSINESS OR PROFITS OR OTHER ECONOMIC LOSSES OR STATUTORY OR EXEMPLARY DAMA...

Reviews: