14
2. Undo and remove the four screws
on the housing (2).
3. Align the transport handle either
horizontally or vertically.
4. Secure the transport handle to the
housing at the required position us-
ing four screws.
5. Screw the other four screws into
the free holes in the housing.
7 Transport and connection
Transport
WARNING!
Crushing as a result of
instability!
Transport the dehumidifier in an
upright position and secure it so
that it cannot tip over or slip.
Position the dehumidifier on a
stable, even surface.
WARNING!
Reaching into the grille of
the air intake area can result in
crushing or cutting!
Use the handles to transport the
dehumidifier.
Do not reach into the air intake
area.
CAUTION!
Crushing or ergonomic
damage when transporting the dehu-
midifier!
Use the handles to transport the
dehumidifier.
The dehumidifier must be trans-
ported by two people.
Procedure
1. Make sure that the condensate wa-
ter is drained away.
2. Make sure that the appliance is
switched off and the mains cable
has been disconnected.
3. Transport the dehumidifier to where
it is going to be used.
NOTE:
The air must circulate freely. Do
not cover the air openings. There must
be a clearance of at least 1 m in front of
the air outlet and air intake area.
Connecting the discharge hose
It is essential to connect the drain hose
provided.
ATTENTION!
Inadequate appliance
output!
Do not place the end of the hose in
the water (backwater possible).
Do not bend the discharge hose.
Do not place any objects on the
hose.
Procedure
1. Attach the drain hose to the Water
outlet on the front of the appliance.
2. Make sure that the end of the hose
is lower than the start of the hose
at the Water outlet. Minimum slope
of 5% (5 cm/metre).
3. Run the discharge hose away from
the dehumidifier to a drain or into a
suitable container (recommended
container volume = 90 litres).
1
2