Blue Angel BPLS Series Operating Instructions And Parts Manual Download Page 2

Use a grounded receptacle to reduce
the risk of fatal electric shock.

Never cut off the 
round grounding

prong on the power cord. Cutting the
cord or plug will make the pump unsafe
to operate and void the warranty.

2. Turn the pump switch to the 'Off'

position.

3. This pump is only for use on 120

volt (single phase), 60 Hz, 15 amp
service and is equipped with a 3-
conductor cord and 3-prong,
grounding type plug. Insert power
cord directly into GFCI outlet (see
Figure 3).

4. Turn pump switch to the 'On' posi-

tion (see Figure 4). If the pump
does not pump water within 10
minutes, turn off pump and refill
with clean water. If the pump does
not operate after repeated
attempts, check the following:

- Vertical distance of pump to water
level must not be over 20 feet.

The inlet hose 
must be a rein-

forced type when pumping from lakes,
ponds, or small streams. Regular gar-
den hose will collapse and lead to
pump failure.

5. A foot valve with strainer should be

used to maintain prime during
operation.

6. Seal all connections in the inlet

hose. An air leak in the fittings,
hose, pipe or connections will draw
air even though no water leaks out.
These inlet leaks will reduce pump
performance and lead to pump fail-
ure.

7. Connect outlet pipe or hose to

pump. The outlet connection is
designed for 1" NPT thread. Rigid
pipe such as PVC or garden hose
may be used. An adapter to garden
hose thread is included (Figure 1).

BOOSTING WATER PRESSURE

Do not run pump 
with outlet pipe or

nozzle closed. The hose may burst from
excessive pressure. Use only reinforced
high-pressure hose or pipe for outlet
pipe.

1. Connect inlet pipe or hose to pump.

An adapter to garden hose thread is
included (Figure 1).

2. Connect the other end of inlet line

to water supply.

3. Connect outlet pipe or hose to

pump.

Operation

Never run the pump
dry. Running pump

without water will cause seal failure.
Fill pump with water before starting.

1. Remove priming port on pump and

fill with water. Reinstall priming
port on pump (see Figure 2).

For

boosting water pressure: Do not
remove priming port. Turn on water
supply.

Risk of electrical 
shock! This pump is

supplied with a grounding conductor
and grounding type attachment plug.

- Suction line must be airtight.

- All valves in suction and discharge
line must be open.

Maintenance

Maintain adequate ventilation for the
pump motor. The motor bearings are
permanently lubricated at the factory.
Additional lubrication is not required.

DRAINING FOR WINTER

Always protect pump and piping
against freezing temperatures. If there
is any danger of freezing, drain the sys-
tem.

1. Disconnect suction and discharge

lines from pump.

2.  Remove plug from lower front face

of pump.

3.  Drain all piping below the frost line,

or store piping indoors.

4. Store pump indoors.

See Figure 5 for replacement parts.

Portable Lawn Sprinkler and Utility Pump

Figure 2

Priming Port
Opening

Figure 3 - Inserting power cord into
GFCI outlet

Figure 4

Power
Switch

2

Operating Instructions and Parts Manual

www.blueangelpumps.com

Summary of Contents for BPLS Series

Page 1: ...mp flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in a flamma ble and or explosive atmosphere Personal injury and or property dam age could result This pump is not des...

Page 2: ...ure 1 BOOSTING WATER PRESSURE Do not run pump with outlet pipe or nozzle closed The hose may burst from excessive pressure Use only reinforced high pressure hose or pipe for outlet pipe 1 Connect inle...

Page 3: ...er level in well is lower than estimated 2 Steel piping if used is corroded or limed causing excess friction 3 Piping is too small in size 1 Be sure switch is on 2 Refer to instructions Check all conn...

Page 4: ...AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHA...

Page 5: ...autre application qui pourraient contenir des produits chi miques caustiques et ou des mati res trang res Des dommages la pompe pourraient d couler si utilis e dans ces applications et cela annulera...

Page 6: ...PVC ou un boyau de jardinage peut servir Un adapta teur pour le filetage du boyau de jardinage est inclus figure 1 RENFORCER LA PRESSION D EAU Ne pas faire fonc tionner la pompe avec un tuyau de sor t...

Page 7: ...orrod ou chaul provoquant une friction suppl mentaire 3 Le conduit est trop petit 1 S assurer que l interrupteur est en marche 2 Refer to instructions Check all connections 1 V rifier aupr s de la soc...

Page 8: ...ADAPTATION UNE FONCTION PARTICULI RE SONT LIMIT ES UN AN COMPTER DE LA DATE D ACHAT CECI EST LE SEUL RECOURS EXCLUSIF ET TOUTE AUTRE RESPONSABILIT POUR TOUT AUTRE DOMMAGE QUELCONQUE INDIRECT OU D PENS...

Page 9: ...sto podr a ocasionarle heridas y o da os a su propiedad Esta bomba no est dise ada para bombear agua salada salmuera agua con deter gentes o para ning n tipo de aplicaci n donde el agua pueda contener...

Page 10: ...exi n a tierra y un enchufe de uni n del tipo de cone xi n a tierra Use un recept cu lo con conexi n a tierra para reducir el riesgo de choque el ctrico mortal Nunca corte la pata redonda de conexi n...

Page 11: ...zadas ocasionando fricci n excesiva 3 Las tuber as son muy peque as 1 Cerci rese de que el interruptor est en ON encendido 2 Refer to instructions Check all wiring connections 1 Cons ltele a la compa...

Page 12: ...ARANTIAS EXPRESAS LAS GARANTIAS IMPLICITAS INCLUYENDO GARANTIAS EN RELACION AL MERCADEO O USOS ESPECIFICOS ESTAN LIMITADAS A UN A O A PARTIR DE LA FECHA DE COMPRA ESTA ES LA UNICA GARANTIA DISPONIBLE...

Reviews: