Blue Angel Pumps 100SW Operating Instructions And Parts Manual Download Page 5

INSTALLATION MANUAL

5

*The pump shown in the diagram above is for illustration purposes only. All 

models (T50SW, F50SW, 200SW, 100SW, and 75SW) can follow this diagram 

and the sewage installation tips.

 

ON LEVEL  

T50SW-APPROX. 19 IN.
F50SW-APPROX. 13 IN.
 

OFF LEVEL 
T50SW-APPROX. 10-1/2 IN.
F50SW-APPROX. 8 IN.

Submersible Sewage 
Pumps

1

3

5

2

7

6

4

8

9

10

11

1.  Check Valve

7.  Tether Switch

2. Union

8.  Power Supply Cord

3.  Discharge Pipe

9.  GFCI Outlet

4.  Inlet Pipe

10.  Gasket/Basin Lid

5. Basin

11.  Vent Pipe

6.   Pump 

MINIMUM 

BASIN

DIAMETER

(18 IN.)

TYPICAL SEWAGE INSTALLATION

1.  This installation must be in accordance with the National 

Electric Code and all applicable local codes and 
ordinances.

2.  Use a basin (5) that is large enough to accommodate the 

pump. The basin diameter should be a minimum of 18 
inches and the depth a minimum of 24 inches.

3.  Clean the basin of all debris. 

4.  Set the pump (6) on a solid, level surface. Do not place 

pump directly on clay, earth, gravel, or sand. A brick or 
block may be installed under the pump to provide a solid 
base.

5.  Position pump (6) in the basin (5) so the tether switch (7) is 

away from incoming water. Verify the tether float switch has 
at least 1 inch clearance to the side wall of the basin and is 
free of any possible obstructions.

6.  Install discharge plumbing according to local, regional and 

state codes. Do not reduce the discharge pipe (3) size 
below that which is provided on the pump (6).

7.    A union (2) should be installed above the basin to allow 

easy removal of the pump (6) for cleaning and service.

8.  Install a check valve (1) (required) to prevent back-flow. 

It should be installed above the union.

9.  A gate valve or ball valve should be installed above the 

check valve if required by local, regional or state codes.

10.  Connect remaining discharge pipe. Keep sections as short 

as possible with a minimum number of turns.

11.  A vent pipe (11) is required. It removes gases and odors 

and should be installed as required by local, regional or 
state codes.

12.  Secure power supply cord (8) to discharge pipe (3) using 

cable or zip ties to prevent possible switch entanglement. 

13.  Connect tether switch (7) piggyback cord to a ground fault 

circuit interrupter (GFCI) outlet (9) (required) then connect 
the pump power supply cord (8) into the piggyback cord.

14.  Fill the basin with water. The pump will start when the 

water level has reached the switch-on level. Verify the 
pump is operating normally.

15.  Install a basin cover and gasket (10) to prevent debris from 

falling into the basin, prevent personal injury, and to contain 
gases and odors.

MINIMUM 

BASIN

DEPTH

(24 IN.)

Summary of Contents for 100SW

Page 1: ...0SW F50SW Cast Iron 200SW 100SW 75SW SHAFT Steel DISCHARGE 2 in NPT T50SW F50SW 3 in NPT supplied 2 in Adapter 200SW 100SW 75SW Sewage Pump www blueangelpumps com Intended for Indoor Use Only T50SW Te...

Page 2: ...ompe est fournie avec un conducteur et une fiche de mise la terre Pour r duire le risque de choc lectrique s assurer qu elle est branch e seulement une prise de courant correctement mise la terre FOR...

Page 3: ...ACHEMINEMENT D EAU DESTIN E LA CONSOMMATION Ne pas utiliser la pompe pour transporter de l eau qui sera utilis e comme de l eau potable destin e la consommation La pompe doit tre utilis e uniquement d...

Page 4: ...USED when risk of property damage from high water levels exists UNE ALARME AUTONOME DE NIVEAU D EAU LEV OU UNE POMPE DE SAUVEGARDE DOIVENT TRE UTILIS ES en cas de risque de d g ts mat riels caus s par...

Page 5: ...to the side wall of the basin and is free of any possible obstructions 6 Install discharge plumbing according to local regional and state codes Do not reduce the discharge pipe 3 size below that whic...

Page 6: ...otion of switch 3 Remove obstruction in discharge piping 4 Contact an electrician TROUBLESHOOTING WARNINGS ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY before installing servicing or making any adjust...

Page 7: ...Contact an electrician 2 Remove debris 3 Replace pump 4 Recheck all sizing calculations to determine proper pump size 5 Remove and examine check valve for proper installation and free operation 6 Ope...

Page 8: ...WARRANTY SERVICE PARTS SHEET REPLACEMENT PARTS 8 1 2 REPAIR KITS REF NO DESCRIPTION PART NUMBER 1 20 FT POWER CORD 31006 WYN1 2 Tether Float Switch Kit T50SW Only 66051 WYN1...

Page 9: ...EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE...

Page 10: ...10 NOTES...

Page 11: ...11 NOTES...

Page 12: ...12...

Reviews: