E
nglish
18
BLUCP700E
19. What to do in case of dysfunction
In case of dysfunction, the BLUCP700E Compact pump is disused. The „service informati-
on LED“ signals the error code by the numbers of the flashing process.
The error code may be cancelled by removing and plugging in battery; this also resets
the system. (The error codes shown below provide information to eliminate the problem).
If the problem persists after resetting the BLUCP700E Compact pump, apply to the BLU-
CHER customer assistance service.
Error message - code 1:
Check the oil level
Procedure: Unscrew the oil cap; if you cannot check the oil level, top up the oil to the
brim with „Shell-Naturelle HF-E15 hydraulic oil“. (see 19.2)
Error message - code 7:
Check the air filter
Procedure: Check the air filter, which is located above the power pack compartment
and replace it if necessary. (see 19.3)
19.1 Error codes
Indications after inserting the power pack
Assistance
LED
Battery
LED
Error
code
Description
flashing red
flashing red
Boot loader activated
flashing orange
Error during initialization of the SD card
lightning green
Regular initializations
lightning red
3
Battery tension low
Indications after inserting the power pack
Assistance
LED
Battery
LED
Error
code
Description
lightning red
1
Operating range not achieved at timeout
lightning red
2
Operating value in red area
lightning red
Operating value in yellow area
lightning green
Operating value in green area
lightning red
3
Battery tension low
flashing red/green
Assistance service interval expired