19.  What to do in case of dysfunction

In case of dysfunction, the  BLUCP700E  Compact pump is disused. The „service informati-
on LED“ signals the error code by the numbers of the flashing process. 

The error code may be cancelled by removing and plugging in battery; this also resets 
the system. (The error codes shown below provide information to eliminate the problem).
If the problem persists after resetting the  BLUCP700E  Compact pump, apply to the   BLU-
CHER  customer assistance service.

Error message - code 1: 

Check the oil level

Procedure: Unscrew the oil cap; if you cannot check the oil level, top up the oil to the 
brim with „Shell-Naturelle HF-E15 hydraulic oil“. (see 19.2)

Error message - code 7: 

Check the air filter

Procedure: Check the air filter, which is located above the power pack compartment 
and replace it if necessary. (see 19.3)

19.1  Error codes

Indications after inserting the power pack

 

 

 

 

Assistance
LED            

Battery
LED            

Error

code

Description

flashing red

flashing red

Boot loader activated

flashing orange

Error during initialization of the SD card

lightning green

Regular initializations

lightning red

3

Battery tension low

Indications after inserting the power pack

Assistance
LED            

Battery
LED            

Error

code

Description

lightning red

1

Operating range not achieved at timeout

lightning red

2

Operating value in red area

lightning red

Operating value in yellow area

lightning green

Operating value in green area

lightning red

3

Battery tension low

flashing red/green

Assistance service interval expired

Summary of Contents for CP 700E

Page 1: ...ic pump with accumulator Instruction manual BLUCP 700E Drainage and pressure piping solutions PO Box 107 Corunna Avenue Melrose Park SA 5039 T 08 8374 3426 M 0425 567 241 spaterson blucher com au www...

Page 2: ...Please read this instruction manual carefully before using our pro duct In case of any open issues or questions please contact our service center immediately Find Information on the last cover page 2...

Page 3: ...rol unit 13 13 Working cycles standard program 13 13 1 Compression working cycle 13 14 Tool variations 14 15 Maintenance instructions 15 16 Technical features and performance 15 17 Rating plate 16 18...

Page 4: ...m 20 C to 50 C Dimensions basic unit approx 300 x 195 x 210 mm incl power pack Mass basic unit approx 4 7 kg incl power pack Class of protection IP 43 Item Definition Item Definition 1 LED operating i...

Page 5: ...E nglish BLUCP700E 5 1 2 3 5 8 6 7 9 11 4 10...

Page 6: ...equipment or materials MOperation and maintenance Advice and indications in order to maintain the product s value NInformation Useful information for the proper application of this product 3 Accessori...

Page 7: ...vely for its intended use This product shall only be used by personnel who have received training whereas the instruction manual must be carried along with the device for its entire life period The us...

Page 8: ...pressure hose must must be designed for a nominal pressure of 700bar 70MPa and must not be damaged bent or worn ACaution In the event of serial assembly it is necessary to use the shoulder strap pro...

Page 9: ...d entail the loss of guarantee and can lead to situations of danger Caution The typical A weighted noise level can exceed 70dB A during operation Wear ear protection ACaution The equipment shall only...

Page 10: ...charger A 3 0 Ah power pack can be recharged in approximately 60 minutes The status of the charge for the power pack is indicated by the luminous diode on the battery charger Remove the protection cap...

Page 11: ...rage periods the state of charge of the battery must be checked periodically The optimum charge is between 50 and 80 The power packs should be recharged every 12 months at most to avoid complete disch...

Page 12: ...should only be used for assessing the power reserve The real power consumption depends on the applied working parameters which are taken into account by the battery indicator on your Compact BLUCP700E...

Page 13: ...green LED lights up on the remote control unit at the same time the green info service LED lights up as well signalling that the working cycle has been successfully concluded If the button is release...

Page 14: ...ection for tight ness Both the connectors must be totally clean Disconnecting is performed in reverse order Connecting and disconnecting is only possible in depressurized state The pump must be turned...

Page 15: ...w to high pressure takes place at approximately 90 bar 9 MPa The machine has great reverse capacity for quicker working cycles The equipment has a volume recogniton system that permits precise work wi...

Page 16: ...rding to the conditions of use Integrated and intelligent electronic module with a large LCD display 17 Rating plate Manufacturer BLUCHER Item Nr BLUCP700E Compact pump Serial Number BLUCP700E Year of...

Page 17: ...tely 4 Push button on the remote control one time only Automatically LED will light green 5 Compact pump is detected 6 run setup exe Installation of software by CD point 6 10 7 8 9 click finish 10 rem...

Page 18: ...15 hydraulic oil see 19 2 Error message code 7 Check the air filter Procedure Check the air filter which is located above the power pack compartment and replace it if necessary see 19 3 19 1 Error cod...

Page 19: ...rror code Description lightning red 4 Error during initialization of sensor temperature lightning red 8 Drop in pressure during compression lightning red 9 Fan not working lightning red 10 Control of...

Page 20: ...remote control by 90 battery on top with a coin 4 Fill to the brim with hydraulic oil 5 Tighten screw Shell Naturelle HF E15 with a coin 19 3 Changing the filter 1 Disconnect coupling 2 Lift the devic...

Page 21: ...formity with EU Directive 2002 96 EEC The crossed out mobile dustbin shown on the device indicates that this product must be disposed of separately from domestic waste at the end of its lifetime There...

Page 22: ...y and charger must be protected against moisture and foreign material Check carefully the functionality and intactness of the unit and the moving parts The guarantee includes the removal of all occuri...

Page 23: ...arie is in conformity with the following EC directives es conforme con las siguientes directivas comunitarias est conforme aux directives communautaires suivantes 2006 42 EG 2006 95 EG 2004 108 EG und...

Page 24: ...Service...

Reviews: