REV. 02 - MARCH 2021 - BLÜCHER
®
CONNECTED ROOF
7
4.3
Monitor specifications
Power supply
Battery
Lithium battery LS 14500 3.6V (internal) AA
Battery life
Up to 10 years
Level Sensor
Sensor electrodes
Stainless A2
Enclosure
IP protection
IP68
Material
Anti-UV PC
Size
120 x 65 x 60mm
Environmental
Working temperature
-35°C - 85°C
Storage temperature
-35°C - 85°C
5
Mechanical installation
5.1 Gateway
We recommend that the Gateway is placed centrally in relation to the Monitors, and in line
of sight to ensure the best possible signal strength. Please note that obstructions such as
concrete and metal can reduce the signal range.
Do not install the BLÜCHER
®
Connected Roof Gateway in areas with a risk of water exposure and high humidity levels.
The ambient temperature should be in the range between -10 °C and 55 °C and the humidity below 80% non-condensing.
Please consider the material/thickness of the gateway enclosure for maximized signal strength.
Temperature
-10 – 55°C
Humidity
< 80% - non
condensing