background image

13

®

COVE 2 MKII 

DIMENSIONS (mm)

 

LOW STAND

(

Shown above)

LOW ARCH STAND

MIDI STAND

STORE STAND

CENTRE STAND

a b

c

d

e

697

647

103

76

532

697

647

103

76

532

824

774

230

203

659

944

894

350

323

779

944

894

350

323

779

b

c

d

e

a

FRONT VIEW

SIDE VIEW

BACK VIEW

TOP VIEW

96

162

403

418

152

159

567

520

600

Optional vertical rear flue adaptor

Optional external air manifold kit

charnwood

Summary of Contents for Charnwood Cove 2

Page 1: ...Operating Installation Instructions charnwood 2 3 ...

Page 2: ......

Page 3: ...Clearing 6 Chimney Sweeping 7 Trouble Shooting 7 CO Alarm 8 If You Need Further Help 8 INSTALLATION INSTRUCTIONS Health Safety Precautions 9 CO Alarms 9 Specification 9 Chimney 9 Hearth Fire Surround 10 Connection to Flues 10 Soot Doors 10 Unpacking The Stove 10 Fitting The Stove To Its Stand 10 11 Pre Lighting Check 11 Commissioning 11 Clean Air Act Information 12 Dimensions 13 14 Parts Lists 15 ...

Page 4: ... begins to require extra force then the cause must be investigated and corrected to prevent damage being caused to the stove Remember that the stove will be hot and is made from hard material Ensure that you have good balance before operating the fire When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with...

Page 5: ...mmend the use of a stove pipe thermometer which may be purchased from your supplier or from Charnwood The Cove 2 blu is fitted with an air control stop for use in a smoke control area This stops the stove from burning too slowly REFUELLING Keep the firebox well filled but do not allow fuel to spill over the top of the fuel retainer Logs should be evenly distributed filling the firebed to give the ...

Page 6: ...hen special high temperature paints are available from your supplier or from Charnwood Cleaning the Glass The glass in the door is a special ceramic glass which is able to withstand high temperatures Before cleaning the glass open the door and allow it to cool Clean the glass using a damp cloth and then wipe over with a dry cloth Any stubborn deposits on the glass may be removed with a proprietary...

Page 7: ...guide wheel is recommended For prefabricated insulated chimneys the manufacturers instructions with regard to sweeping shouldbeconsulted TROUBLE SHOOTING Fire Will Not Burn Check that a the air inlet at the rear of the stove is not obstructed in any way b chimneys and flueways are clear c a suitable fuel is being used d there is an adequate air supply into the room e an extractor fan is not fitted...

Page 8: ...om the Charnwood Customer Services department who will be pleased to give advice if necessary CAA AND SMOKE CONTROL The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or 8 charnwood part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed ...

Page 9: ...ctly or ensuring regular servicing and maintenance of the appliance and chimney system SPECIFICATIONS CHIMNEY In order for the appliance to perform satisfactorily the chimney height must not be less than 4 metres measured vertically from the outlet of the stove to the top of the chimney The minimum internal chimney sizes are as follows COVE 2 150mm diameter 6 inches or 150mm x 150mm COVE 3 180mm d...

Page 10: ...e sealing face of the flue collar should be coated with fire cement before fixing to the body of the stove using the two screws provided The blanking plate must be removed sealed with fire cement and refitted care being taken to ensure that the fold on the clamping plate is in line with the lugs on the firebox as shown on the label on the clamping plate Ensure that the clamping plate does not prev...

Page 11: ...ighting the following points should be checked 1 The bottom grate bars must all be fitted and should move freely and easily when the riddling mechanism is operated 2 The plates round the sides and back of the grate must be in position and sitting correctly 3 The throat plate must be fitted in the roof of the appliance and should be checked to ensure that it has not become dislodged in transit The ...

Page 12: ... appliances are exempted bypublication on a list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Northern Ireland appliances are exempted by publication on a list by the Department of Agriculture Environment and Rural Affairs under Section 16 of the Environmental Better regulation Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by...

Page 13: ...D CENTRE STAND a b c d e 697 647 103 76 532 697 647 103 76 532 824 774 230 203 659 944 894 350 323 779 944 894 350 323 779 b c d e a FRONT VIEW SIDE VIEW BACK VIEW TOP VIEW 96 162 403 418 152 159 567 520 600 Optional vertical rear flue adaptor Optional external air manifold kit charnwood ...

Page 14: ...IONS mm 1130 980 110 115 844 1130 980 110 115 844 1200 1150 280 285 1014 1330 1280 410 415 1144 1330 1280 410 415 1144 b c d e a a b c d e 179 191 441 178 619 439 585 113 660 Optional vertical rear flue adaptor FRONT VIEW SIDE VIEW BACK VIEW TOP VIEW Optional external air manifold kit charnwood ...

Page 15: ... Door Catch 26 010 ST031 Door Catch Spacer 27 008 FFW015 M12 Double Coil Spring Washer 28 008 PX95 Door Riddling Ashpan Tool 29 008 BW39 S Hinge Pin Set 30 002 PY24 Hinge Post 31 004 PY25B Hinge Post Shim 0 9mm 32 004 PY25A Hinge Post Shim 2mm 33 008 AY37 Air Control Knob Item Part No Description 34 004 CY22S Secondary Air Inlet Flap 35 004 CY21 Air Bypass Slide 36 004 CY22P Primary Air Inlet Flap...

Page 16: ...002 PX92 Door Knob Spindle 23 008 FFN001 M12 Half Nut 24 004 ST008 Tabbed Locking Washer 25 002 AY14 Door Catch Cam 26 010 ST031 Door Catch Spacer 27 008 FFW015 M12 Double Coil Spring Washer 28 008 PX95 Door Riddling Ashpan Tool 29 008 PV28 S Hinge Pin Set 2 Per Set 30 004 GV24 Rear Brick Joining Bracket 31 002 RY26 Hinge Post 32 004 RY25B Hinge Post Shim 0 9mm 33 004 RY25A Hinge Post Shim 2mm 34 ...

Page 17: ...015 RXE44 CPD 2015 Fuel type WOOD LOGS WOOD LOGS Emission of CO in combustion products 0 10 0 10 Mean flue gas temperature 336 C 330 C Flue spigot temperature 403 C 396 C Space heating thermal output 8kW 12kW Energy efficiency 77 80 Minimum distance to combustible materials Side Rear 450mm 600mm 500mm 500mm Particles mg m ⁿ 15 14 Fulfilled requirements BStV of the City of Munich and the City of Re...

Page 18: ......

Page 19: ... e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M y o u r p re m i e r d e a l e r ...

Reviews: