35
Does not charge
– remind error charge
YES
YES
NO
YES
Remind: “fault connection”
“battery overheat”
Check capacitor C205
、
resistor
R211\R208 be normal
Replace or re-solder
CPU U101 MT6260
Remind error during
charge
Check charge protective tube
Q201 be normal.
Check battery connector
testing Pin, if the bias resis
and vatge be normal.
Change battery
Re-flash SW
Resolved
Replace
or
re-solder
NO
NO
NO
YES
YES