Do not use the device in room with inflam-
mable fumes and gas.

t

The  device  should  be  kept  out  of  reach  of 
children and animals.

t

During the assembly use the filter on the hy-
draulic supply.

t

Please use the following valves. 
- vent valve in the highest place on the 
hydraulic installation, 
- cut off valve on the supply and return of 
the device.

t

The  device  should  be  secured  against  pres-
sure increase in the water installation.

t

Before  plugging  the  electric  supply  check 
the leak tightness.

t

The device does not consist of the anti-frost 
protection.  The  temperature  in  the  room 
should not go below 0°C. In such case please 
empty the device out of water.

t

It  is  recommended  to  check  the  electric  in-
stallation before the first start.

t

It  is  recommended  to  use  the  external  
current differential protection. 

t

After the turn off, the elements of device may 
be warm. 

t

After  operating  time  of  the  device,  please 
utilize  it  concerning  the  local  norms  and  
regulations.

t

It is recommended to clean the device 
periodically: 
- heating coil blow through by compressed air, 
- fan casing and blades clean form the dirt.

t

If the device is not used for a longer time dis-
connect the voltage supply.

t

The device is transported with the closed air 
stators. It is essential to open them in 30 % 
before first start. Not keeping to the follow-
ing  recommendation  may  cause  the  dam-
ages of the fan.

t

Opening the air stators must be made by two 
hands in parallel. Not keeping to the follow-
ing  recommendation  may  cause  the  dam-
ages of the air stators.

t

While  plugging  the  device  to  the  water  in-
stallation do remember to hold its stub pipes 
by pipes spanner, not keeping to the recom-
mendation  may  cause  the  damages  of  the 
heating coil.

9. Blowair automatics.

To make easier the usage of the Blowair devices we 
also offer the additional automatics:

5-stage  speed  controller  Blowair  RX  1,2A- 

  is 

used to control the speed in single-phase fans. It 
consists of 5 controls  0 - 70 - 85 - 105 - 145 - 230V, 
power  supply  voltage-230VAC  /  50-60Hz,  allow-
able  current  output:  1,2A;  protection:  thermal 
breaker  switch;  dimensions:  126mm  x  176mm  x 
56mm;  weight:  1,3  kg.  It  is  recommended  to  use 
one speed controller to each Blowair device.

5-stage speed controller Blowair RX 3A

-  is used 

to  control  the  speed  in  single-phase  fans.  It  con-
sists  of  5  controls    0  -  70  -  85  -  105  -  145  -  230V, 
power  supply  voltage-230VAC  /  50-60Hz,  allow-
able current output: 3A; protection: thermal break-
er switch; dimensions: 126mm x 176mm x 56mm; 
weight: 1,3 kg. It is possible to use one RX 3A speed 
controller for a few Blowair devices.

Two-way  valve  with  actuator  BR  3/4”

-  connec-

tion diameter ¾”. It should be installed on the re-
turn (outlet) pipe. Using it, lowers the living costs. 
It is essential to use it with the temperature con-
troller. After reaching the wanted temperature the 
valve cuts off the water inlet. Water runs in cycle 
and does not cool. The valve is not noisy. It is rec-
ommended to use one two-way valve with actua-
tor to each Blowair device.

Room thermostat RT 100

- work environment pa-

rameters  0°C-40°C;  setting  range10°C-30°C;  regu-
lation  accuracy  1°C;  temperature  number  levels  1; 
power supply voltage 230V. It is possible to use one 
room thermostat to maximum 5 Blowair devices.

Programmable temperature controller FL

- sav-

ing energy up to o 30%. It is possible to regulate 
the temperature up and down. LCD liquid crystal 
display.  Temperature  setting  every  0,2°C.  It  con-
sists  of    9  programmers.  3  levels  of  temperature- 
day, night, anti-frozen. Work environment param-
eters  0°C-40°C.  Setting  range  5°C-30°C.  Power 
supply 2 alkaline battery AA (1,5V). Permitted con-
trol output load 230 VAC 50Hz 5 (3) A. It is possible 
to use one programmable temperature controller 
to maximum 5 Blowair devices.

10.  CONNECTION SCHEMES

PE- protective earthing, duct yellow-green colour; 
N- neutral, duct black-black colour; 
L- phase duct, duct brown colour; 
Empty clamp, duct blue-black colour.