1. INTRODUCTION

Thank  you  very  much  for  purchasing  our  device. 
We would like to congratulate you on good choice.

1.1. PRECAUTIONS

The buyer and the user of the device should read 
carefully  the  following  instructions  and  proceed 
to the content recommendations. Proceeding due 
to  the  following  instruction  guarantees  the  cor-
rect usage and safety. In case of any doubts please 
contact the producer. 

The producer reserves the rights to make changes 
to the technical documentation without previous 
notice. 

The producer is not responsible for the damages 
which  occur  due  to  improper  installation,  not 
keeping  the  device  in  repair  or  using  the  device 
out of line. 

The installation should be carried out by the pro-
fessional installers, who possess the qualifications 
to install these types of devices. The installers are 
responsible for making the installation as instruct-
ed  in    the  technical  data.  Regulations  and  safety 
rules must be followed.  

During the installation, use, service and periodical 
inspections  all  regulations  and  safety  rules  must 
be followed. 

In case of unserviceable please plug out the device 
and contact with the authorized person or the pro-
ducer. 

1.2 TRANSPORT

During  the  acceptance  of  goods  it  is  needed  to 
check the device in order to exclude any damages. 
During the transport it is needed to use the proper 
equipment,  it  is  necessary  to  carry  the  device  by 
two people. In case of any damages please fill in 
the damage report in presence of the supplier. 

1.3 PACKAGE CONTENT 

t

)FBUFS

t

*OTUSVDUJPOBOEXBSSBOUZDBSE

 
 

1.4  USE AND PRINCIPLE OF OPERATION

Devices BLOWAIR Farmer 47 kW are used to heat 
large-size rooms. These units are suitable to work 
in  aggressive  environments,  with  high  dustiness, 
humidity  and  concentration  of  ammonia  in  the 
air.    Because  of  the  LCE  coating,  the  devices  are 
fully covered with the protective layer. The deposit 
which occurs in aggressive environments does not 
stick to the units. Additionally water heaters FARM-
ER 47 kW have antibacterial layer.

Air water heaters have to be connected to central 
heating system.

Application  of  new  technologies  in  Blowair  de-
vices  guarantees  high  effectiveness  and  comfort 
of the consumption. Original colors of the devices 
mach to every interior.  The devices are made very 
precisely  and  will  work  smoothly  for  many  years. 
The product has got the two years of warranty.

2. SCHEMATIC DIAGRAM 

 

2.1 CONSTRUCTION

t

Casing

t

Air stators

t

Heating coil

t

Axial fan

t

Holders

t

Rotational holder

Casing- 

is  made  of  galvanizing  steel,  powder 

painting  in  RAL  color  7035,  covered  with  LCE 
coating.

Air stators- 

are made of galvanizing steel, powder 

painting in RAL color 7035. It is possible to set the 
air stators up manually to achieve the needed di-
rection of the air flow. 

Heating  coil- 

is  made  of  aluminum    and  copper.  

The maximum temperature of the heating factor is 
110°C; maximum pressure 1,6 MPa; headers diam-
eter ¾”. Water heater Farmer has two rows heating 
colis.

Axial  fan-  fan  casing

  –  metal,  powder  painting, 

steel wire galvanized. The motor has got the safety 
degree IP 54.

Holders-

 are additional elements to assemble the 

device. It is solid and durable, it is possible to as-
semble the device on the wall or ceiling. It is also 
possible to regulate the angle of slope in three ver-
sions. 

Rotational holder

- is an additional element to as-

semble the device . It is solid and durable, it is pos-
sible to assemble the device on the wall or ceiling. 
It is possible to assemble the device in parallel on 
the angle 60° and 45°.

3. DESCRIPTION OF THE NEW TECHNOLOGY  
     LCE COATING 

3.1 ADVANTAGES OF LCE COATING:

t

increase lifetime of water heaters in aggres-
sive environments;

t

antibacterial  layer,which  prevents  develop-
ment of bacteria inside the heating coils;

t

LCE coating has no influence on capacity;

t

LCE coating is spread on the water heater by 
deep  immersion,  because  of  it  LCE  coating 
reaches each slit of the coils;

t

hydrophobic surface;

t

LCE  coating  has  strong  bond  to  the  water 
heater’s surface.

 

3.2  ANTI-CORROSION  SOLUTION,  WHICH  RE-
ALLY WORKS:

LCE  coating  gives  elastic  layer  on  the  whole  sur-
face  of  the  coil. This  layer  is  able  to  last  thermal 
dilatation of the coil without cracking.

The end with corrosion.

Water heaters very often work in aggressive envi-
ronments  such  as:  ocean  coast,  food  production 
lines, animal shelters, piggery, chicken farms and 
so one where standard protection is not enough. 
LCE  coating  offers  perfect  solution  for  heaters  in 
such environments.

3.3 CERTIFICATES:

ASTM B1 1 7 

Neutral Salt Spray Test 1 0000 hours 

in heating/cooling cycles changing temperatures 
between 60 °C and 5°C;

ASTM G 85 A1 

Acetic Acid-Salt Spray Test to prove 

positive impact on coils used in food industry;

ASTM  G87 

Same  as  G85  utilizing  acidic  SO2 

electrolyte;

ASTM  D552

  Flexibility  Test,  which  investigates 

flexibility of coating to bond to the substrate sur-
face of coil;

ASTM G 85 A5

 Indirect spray of dilute salt and am-

monium sulphate at 23°C and followed by 1 hour 
exposure of dry air at 35°C. Test proving resistance 
in salt containing environment and industrial ap-
plications;

ASTM G 21 

Resistance of polymer coatings to fun-

gi. Important aspect for evaporators.

New  technology  called  LCE  coating  protects  the 
water heaters from corrosion, mould and bacterias 
in a very efficient way. LCE coating is based on wa-
ter, and it brings additional effects as: antibacterial 
and and waterproof effects.

Total immersion application, while LCE coating fills 
into all spaces in the coil.

What is more, the whole casing is being put into 
the LCE coating so it is also protected from aggres-
sive environments.

4. DIMENSIONS

ENG

Reviews: