MASTER CONTROL PANEL

SCREWDRIVER

COUNTERTOP

WELLSLOK

GASKET

WARMER FLANGE

UNITS ARE SHIPPED THREE PHASE AND ARE FIELD CONVERTIBLE TO SINGLE PHASE

1 PHASE

3 PHASE

8 AWG Cu

8 AWG Cu

MODEL

VOLTS

WATTS

AMPS PER LINE 3 PHASE

SINGLE

TEMP.

FIELD WIRING GAUGE

RATING

HT-527

HT-527

240

208

6200

8300

17.9

20.6

34.4

29.8

10 AWG Cu

10 AWG Cu

90°C

90°C

L1

L2

L3

25.8

29.8

11.9

13.8

AMPS

PHASE

FLEXIBLE CONDUIT

CONTROL PANEL WITH

WITH BALL VALVE

1 INCH NPT DRAIN

DROP-IN BAIN MARIE

INSTALLATION INSTRUCTIONS

ELECTRICAL CODES.

APPLICABLE FEDERAL, STATE AND LOCAL PLUMBING AND

THIS EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH

 

OPERATION ONLY.

BAIN MARIE STYLE HEATED TANKS ARE DESIGNED FOR WET

 

NOTES:

 

Control Panel. Check nameplates for voltage and phase.

conduit knockout to terminal block supplied within the Master

supply leads (see 'WIRING REQUIREMENTS' label) through

1. Final connection is accomplished by bringing proper power

TO WIRE:

 

2. Connect 1" drain connection to a suitable drain line.

valve handle is at the discretion of the fabricator (see drawing).

1. A drain with valve is supplied on all units. Location of the

TO PLUMB:

302964-4  REV (-)

INSTALLATION INSTRUCTIONS

STYLE HEATED TANK

MODEL HT-527

WELLS/BLOOMFIELD * VERDI, NV

ELECTRICAL

CUTOUT DETAILS

PRODUCT DIMENSIONS

screws supplied.

4. Mount Control Panel onto electrical box using the

3. Mount Control Box to apron cutout as shown in drawing.

required to secure flange tightly to countertop.

Wellslock frame and twist ears outward (clockwise) as

2. From underneath, insert screwdriver into slots in

flange.

to the underside of gasket supplied on the mounting

to countertop, apply a bead of silicone adhesive/sealant

RECOMMENDATION: Before final seating of modular section

position.

Lower modular section into countertop cutout and

the countertop cutout, then through the apron cutout.

1. Tilt and pass Control Panel and electrical box through

Master Control Panel when making installation.

IMPORTANT - DO NOT disconnect lead wires from the

TO INSTALL:

 

3. Cut out holes.

apron using the control box as a template.

2. Lay out and fabricate control panel holes in counter

1. Lay out "cutout" dimensions on countertop and front apron.

TO FABRICATE:

 

the unit to avoid contact with elevated temperatures.

recommended that a baffle be placed 12 inches below

3. If storage is to be used underneath the unit, it is

2. Unit shall be accessible for servicing from the bottom.

and 10 3/4 inches to surface below the unit.

4 1/8 inches to front wall, 1 inch to back and side walls,

Wooden and Metal Installation: DO NOT install closer than

1. Required installation clearances:

 

OUTLINED BELOW UPON INSTALLATION:

INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY

CLEARANCES

BACK

SIDE

BOTTOM

FRONT

(25)

1

1

(25)

(273)

10 3/4

(105)

4 1/8

MINIMUM CLEARANCE REQUIRED

FROM UNIT TO THE NEAREST SURFACE

INCHES

(MM)