background image

M595 

 p/n 

2M-

Z19817

  

Owners Manual 

Heated Dispenser

5

OPERATION

CAUTION:  

Burn Hazard 

Exposed surfaces of the            

appliance may be HOT to the 

touch and can cause burns.

NOTE:  

Product may continue 

to flow for several seconds after 

the faucet is released.  Do not 

remove the container until all 

flow has stopped.

IMPORTANT: 

Your local Health 

Department can advise whether 

or not a particular product may 

be left in the dispenser over-

night.

IMPORTANT:

Temperature adjustment to 

be performed by authorized        

personnel only.

PREPARATION

Prior to first use, thoroughly clean warmer (see page 6).

Be sure faucet handle is “up” and that drip tray is in place under 

faucet.

USE

Pour product into warming tank.  Using pre-heated product will 

reduce heat-up time.

 

Model HD8799 utilizes a fixed thermostat to hold

 

product at 140ºF (60ºC).

Reinstall tank cover.
Plug dispenser into an appropriate electrical receptacle.   

Turn power switch to 

ON.

When the READY light glows, product is ready to serve:

 

Place an appropriate container under the faucet.

 

Pull the faucet handle to dispense product.

 

Release the handle to stop the flow of product.  

NIGHTLY CLOSE

Turn the power switch to 

OFF

 and unplug the dispenser.  

If required, empty the dispenser and clean. 

Summary of Contents for HD8799B

Page 1: ...Dispenser IMPORTANT DO NOT DISCARD THIS MANUAL This manual is considered to be part of the appliance and is to be given to the OWNER or MANAGER of the restaurant or to the person responsible for TRAIN...

Page 2: ...replacement of fuses and indicating lights are not covered under warranty 5 All problems due to inadequate water supply such as fluctuating or high or low water pressure 6 All problems due to mineral...

Page 3: ...eration and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to properly...

Page 4: ...2 M595 p n 2M Z19817 Owners Manual Heated Dispenser FEATURES OPERATING CONTROLS Fig 1 Features Operating Controls IL2955...

Page 5: ...st be read and understood by all operators and users Except as noted this piece of equipment is made in the USA and has American sizes on hardware All metric conversions are approximate and can vary i...

Page 6: ...m electrical shock in the event of internal damage Never cut off the ground prong nor twist a blade to fit an existing receptacle Contact a licensed electrician to install the proper circuit and recep...

Page 7: ...ly PREPARATION Prior to first use thoroughly clean warmer see page 6 Be sure faucet handle is up and that drip tray is in place under faucet USE Pour product into warming tank Using pre heated product...

Page 8: ...er from the warmer 4 Wipe the warmer inside and out with a soft cloth or sponge dampened with water and mild detergent 5 Rinse the warmer inside and out with a soft cloth or sponge dampened with clean...

Page 9: ...ct wiring for burnt wires and proper connections Repair as needed Power cord damaged Replace power cord Thermostat damaged Replace thermostat Power switch damaged Replace power switch Ready light does...

Page 10: ...H 1 1 4 WS 8600 27P NUT RETAINING WINGED 10 2E 70017 POWER CORD 120V NEMA5 15P 6 1 1 5 2P 87740 SHANK FAUCET W O SIGHT GLASS 11 WS 68689 STRAIN RELIEF 120V STRAIGHT 1 1 6 2U 87739 C RING STAINLESS STE...

Page 11: ...internal components are accessible by removing the bottom panel Remove four screws around the bottom of the warmer tank to free bottom panel from tank assembly FAUCET The faucet may be removed from th...

Page 12: ...10 Sunnen Drive St Louis MO 63143 telephone 314 678 6336 fax 314 781 2714 www bloomfieldworldwide com...