TROUBLESHOOTING SUGGESTIONS
10
SYMPTOM
POSSIBLE CAUSE
SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit breaker
tripped
Check power supply cord
Check / reset circuit breaker
Thermostat set too low
Set for desired temperature
Hi-Limit thermostat tripped
Allow to cool
Reset hi-limit (8786, 8788)
Damaged internal component or wiring
Examine wiring & connectors,
thermostat and heating element Repair/
replace as needed
Pourover - no water or too little water
added at startup
%HVXUHWRDGGVXI¿FLHQWZDWHUVHHSJ
6 START-UP)
Coffee level low (pour-over)
Not enough water poured in
Increase water amount
Too much coffee grounds
Adjust amount of grounds
Coffee level too high or low
(automatic)
Timer out of adjustment
Adjust timer
%UHZFKDPEHURYHUÀRZV
7RRPDQ\¿OWHUSDSHUVRUZURQJ¿OWHU
paper
8VHRQHJHQXLQH%ORRP¿HOG¿OWHU
per brew
Brew chamber dispense hole plugged
Thoroughly clean brew chamber
7RRPXFKFRIIHHRUWRR¿QHDJULQG
Adjust coffee amount and grind
Sprays water from brew head
Spray gasket improperly installed
Check/reinstall gasket on INSIDE of
brew head
Spray disk plugged
Clean spray disk
No brew (automatic)
Water supply OFF
Turn water supply ON
Solenoid strainer plugged
Clean strainer
:DWHU¿OWHULIXVHGSOXJJHG
5HSODFH¿OWHUHOHPHQW
Bad BREW switch
Replace switch
Damaged internal component or wiring
Examine wiring & connectors, brew
switch and solenoid, Repair/replace as
needed
1RÀRZIURPKRWZDWHUIDXFHW
Faucet valve turned OFF
Turn faucet valve ON
Faucet plugged
Disassemble faucet, clean
Poor coffee quality
Water not hot enough
Adjust water temp 195-205ºF
.HHSEUHZHUDLUSRWVDQGVHUYHUVFOHDQ,QVWDOODWDVWHDQGRGRU¿OWHULQZDWHU
VXSSO\DQGUHSODFHFDUWULGJHVUHJXODUO\8VHDTXDOLW\FRIIHHZLWKDFRQVLVWHQWURDVW
8VHSURSHUJULQGDQGDPRXQWRIFRIIHHSHUEUHZ
6
25
p
/n 2M-75873 8792, 8793 Dual Coffee Brewer