background image

PULSE BREW AND PRE-INFUSION (continued) 

Pulse Feature Operation  
 
 
 
 
 
 
 
 
 
 
 

 
Water Outflow (Delivery)
Rates

 

The pulse feature will be activated if it has been accessed as 
above, and values have been programmed into the 3 pulse brew 
items.  When the pulse brew begins, the brew valve will be 
opened for the number of seconds programmed for “Initial Valve 
Time” (Init Vlv Time).  The valve will then close for the number of 
seconds in “Pulse Delay”, then open for the number of seconds in 
“Pulse Valve On”.  The pulse cycle (Pulse Delay plus Pulse 
Valve) will be

    repeated continuously until the brew valve has 

been opened for the “Total Valve” Time

.  The E-Max™ will       

calculate the number of seconds for the full brew and display it on 
the LCD to begin the brew and it will also calculate how many 
pulse cycles are required to complete the brew.  (If a final partial 
“Pulse Valve On” is required this will also be calculated          
automatically.) 

 

The outflow rate of water from the spray head is required to     
calculate valve time for different volumes.  Spray head outflow 
rates are based on the standard 64-ounce coffee brew requiring 
156 seconds of the brew valve being open.  This is an outflow 
rate of 0.410 ounces per second.  To calculate Total Valve time 
the ounces required should be divided by 0.410 oz/second.   
Each brewer may have a slightly different flow rate based on 
whether the brewer is level, scale build up on lines, etc.  Minor              
adjustments may be required to get precise volume.  Examples  
of different volumes and valve times are as follows: 
 

Decanter and Airpot/Thermal Brewers 
Volume  

Total Valve  

in Ounces 

Time 

 

32 

 

88 

            Half of Standard Glass Decanter 

64 

 

177 

            Standard Decanter - ½ gal. brew 

74 

 

205 

      

Airpot 2.2 Liters 

85 

 

236 

      

Thermal Server 2.5 Liter 

 
Tea Brewer 
Brew  

Brew  

Bypass         

Total  

Volume 

Valve 

Valve 

  Ounce 

3 Gal. 

128 oz / 319 sec 

256 oz / 319 sec 

384 

5 Gal. 

212 oz / 529 sec 

428 oz / 529 sec 

640

 

 

20 

654 p/n 

73674

 E-Max™ 

Prog

ra

mm

ing 

M

a

n

ual 

Summary of Contents for E-MAX

Page 1: ...NV 89439 telephone 888 492 2782 fax 888 492 2783 www wellsbloomfield com p n 73674 Rev I ECN 13315 M654 070718 cps 654 PROGRAMMING MANUAL for E MAX COFFEE AND TEA BREWERS E Max BREWERS are covered un...

Page 2: ...CALIBRATION 18 PULSE BREW AND PRE INFUSION 19 TEST PROGRAM E MAX 24 ADDENDUM Extract of Service Bulletin 26 xi Thank You for purchasing this Wells Bloomfield appliance Proper installation professional...

Page 3: ...structions and warnings in the corresponding Service Manual must be read and understood by all operators and users Except as noted this piece of equipment is made in the USA and has American sizes on...

Page 4: ...gular operating mode the E Max maintains the tank temperature within 1 F of the brew temperature Normally this will mean that a brew will be started as soon as the BREW key is pressed However there ma...

Page 5: ...the spray head Place one 1 genuine Bloomfield paper filter into the brew chamber Add your choice of pre measured ground coffee Shake the brew chamber gently to level the coffee Slide the brew chamber...

Page 6: ...Key 6 AIRPOT THERMAL BREWERS TEA BREWERS WITH VOLUME KEY 1 BREW Key 1 2 BREW CANCEL Key 2 3 POWER Key 3 4 STANDARD VOLUME Key 4 5 SMALL VOLUME Key 5 6 LARGE VOLUME Key 6 TEA BREWERS WITHOUT VOLUME KE...

Page 7: ...e brewer will remain ON until the automatic programmed off time when it will turn OFF and resume normal automatic timed functioning Similarly if turned OFF during the automatic timed ON mode the brewe...

Page 8: ...rmal operation heating the water to the Precise Temperature for Brewing PTB before starting the brew The power light will be on continuously and the Brew light will flash until the correct water tempe...

Page 9: ...it will go into the over temperature mode as above with all lights flashing except the LCD will read overheat error and Call for Service To reset press and hold the 2nd key for 3 seconds or re energi...

Page 10: ...brewers and on Tea brewers with volume keys the 4th key is STANDARD Volume and the 6th key is Large Volume On Tea brewers without volume keys the 4th key is hidden under the E and the 6th key is hidd...

Page 11: ...then press 3rd key ON OFF ITEM to get to the required ITEM 3 To Increase Decrease or Change settings when in the programming mode press the 5th or 6th keys Suggestion If the key is pressed and held t...

Page 12: ...10 PROGRAMMING TABLE 654 p n 73674 E Max Programming Manual...

Page 13: ...11 PROGRAMMING TABLE continued 654 p n 73674 E Max Programming Manual...

Page 14: ...Vol 1 This number will be displayed on the LCD when volumes are being changed Pulse Brew To access the pulse or pre infusion programs terminate Brew Vol with the 4th key See Pulse Brew details outline...

Page 15: ...6th keys Decanter Brewers If the Quality Timer is activated each warmer plate will count down from the programmed time when the warmer plate is turned on Once the count down time is reached the appro...

Page 16: ...n the keypad switches can only be activated by pressing and holding the CANCEL key for 6 seconds Then the keypad will be active until a brew has been completed Or if a brew is not started the keypad w...

Page 17: ...e re loaded value if defaults are loaded Re loading of defaults should be used only if major programming problems have occurred and it is necessary to return to factory settings 15 MAX WATER LOCATION...

Page 18: ...Calibration is on the screen The probe is factory set and should not need resetting unless the control ler board or probe is changed See Calibration Instructions following the Factory Settings menu it...

Page 19: ...ce empty decanter or other vessel under the faucet and begin drawing water from the faucet 6 When the inlet valve comes on stop drawing water from the faucet and count the number of seconds before the...

Page 20: ...out the level sensor Insert the thermometer into the brewer Allow time for the thermometer temperature to stablize 5 Once the actual tank temperature has been established look at the values on the scr...

Page 21: ...the water over a longer period of time thus preventing any overflow problems 1 Select the Brew Volume that will be using the pulse brew feature i e go to selected volume BrewVol1 2 3 or 4 in the Brew...

Page 22: ...is required this will also be calculated automatically The outflow rate of water from the spray head is required to calculate valve time for different volumes Spray head outflow rates are based on th...

Page 23: ...ucing 3 pulse cycles each with a 20 second delay Init Vlv Time 10 Pulse Delay 20 Pulse Valve On 54 Total Valve 172 21 1 PRE INFUSION ON ON OFF 30 sec 20 sec 152 sec OFF DRIP OUT 60 sec One Pulse Cycle...

Page 24: ...36 Pulse Valve On 58 Total Valve 236 Pulse Feature Examples TEA BREWERS 1 Pre Infuse Standard 3 gal Brew Total valve time of 319 seconds required for 128 oz of water Init Vlv Time 60 Pulse Delay 30 Pu...

Page 25: ...4 seconds To calcu late the Pulse Valve time Total Valve Time minus Initial Valve Time divided by 4 pulse cycles Init Vlv Time 63 Pulse Delay 34 Pulse Valve On 64 Total Valve 319 Bypass Delay 20 Bypas...

Page 26: ...l return to the off mode 1 Software Firmware Revision will be displayed i e MFW275 Rev3 4 Press ON OFF to advance 2 Data revision will be displayed i e Data Rev2 1 Press ON OFF to advance 3 RTC Real T...

Page 27: ...Probes XXX XXX The left number determines whether the WATER sensing probe is in contact with water A number of 0 or close to 0 means that water is in contact with the probe while a number of 255 or cl...

Page 28: ...replacing a flat spray disk or old style embossed spray disk with an revised embossed spray disk the back pressure of the spray head will be changed Note the altered flow rates for E Max when the new...

Page 29: ...me Initial Valve sec Pulse Delay sec Pulse Valve sec Total Valve sec Bypass Delay E Max T Bypass Valve E Max T After Hours 0 to 6 hr QualityTime Timer Weekday ON hr min Weekday OFF hr min Weekend ON h...

Page 30: ...ION CUSTOMER SATISFACTION Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association Commercial Food Equipment Service Association WELLS BLOOMFIELD LLC 2 ERIK CIRCLE P O Box...

Reviews: