11
CLEANING INSTRUCTIONS (continued)
PROCEDURE: Clean Satellite
PRECAUTIONS: Drain Satellite before Cleaning
FREQUENCY: Twice Weekly
TOOLS: Sight Glass Brush, Sanitizer
Soft Clean Cloth, Bucket
1. Remove and drain satellites. Remove lids.
2. Place 1 packet of Sanitizer into 2-1/2 gallons of warm tap
water. Pour approximately 1 gallon of sanitizer solution into
each satellite. Allow to stand for 2 minutes.
3. Drain sanitizer solution from satellite into the bucket.
4. Disassemble faucet. Brush clean with sanitizer solution.
Reassemble faucet.
5. If necessary, disassemble and clean sight glass.
a. Push down on ears on sight glass guard . Then, pull
ears forward. Lift guard off of retaining clip.
b. Remove sight glass tube from silicone elbow. Run the
sight glass brush through the tube at least ten times.
c. Reassemble the tube to the silicone elbow. Be sure the
elbow has not been pulled from the satellite body.
d. Reinstall the sight glass guard.
6. Reinstall lids. Install satellites on brewer.
7. Rinse satellites: With an empty brew chamber in place, press
the BREW key and run 1 full cycle into each satellite.
8. Drain water from satellites.
Procedure is complete
CAUTION:
Burn Hazard
Brewing and serving
temperatures of coffee are
extremely hot.
Hot coffee will cause
serious skin burns.
IMPORTANT:
DO NOT submerge satellite in
water.
IMPORTANT:
DO NOT use steel wool, sharp
objects, or caustic, abrasive or
chlorinated cleansers to clean
the satellites.
Sight Glass