SERVICING INSTRUCTIONS (continued)
IMPORTANT:
Water pressure
must be between 20 p.s.i and
90 p.s.i. flowing pressure.
If water pressure exceeds this
value, or if water pressure
varies greatly, a pressure
regulator must be installed in
the water supply line.
IMPORTANT:
Before setting
assembly into tank, make sure
tank lid gasket is properly
seated on flange of lid.
IMPORTANT:
When replacing
thermostat, be sure to push
thermo bulb fully to bottom of
thermo well. Tighten gland lock
nut only enough to ensure no
water leakage. Excessive
tightening is not necessary.
IMPORTANT:
When replacing
heating element, also replace
seal gaskets.
BREW TIME ADJUSTMENT
Remove brew chamber and button plug. Adjust TIMER shaft;
clockwise increases time. Brewer should dispense one full
decanter of water. Run several cycles to check amount of water
delivered. Replace button plug.
BREW DELAY ADJUSTMENT
Remove front panel. Adjust DELAY on timer board. Clockwise
increases time. Reinstall front panel.
REMOVE TANK LID ASSEMBLY
Disconnect brewer from electric power. Turn
OFF
water supply.
Remove top panel.
Disconnect fill and outlet tubes from tank lid fittings.
Disconnect all wiring from hi-limit, thermostat and heating
element.
Loosen two lid retainer nuts. Slide retainer out of the way.
Remove cover assembly by lifting it straight up.
Reassemble in reverse order.
REPLACE THERMOSTAT
Unplug brewer. Remove top panel.
Disconnect wiring from thermostat. Loosen screws holding
thermostat to bracket.
Loosen thermobulb gland nut. Withdraw thermobulb from well.
Reassemble in reverse order. Adjust thermostat per page 12.
REPLACE TANK HEATING ELEMENT
Remove tank lid assembly per above.
Remove two hex nuts holding element to cover. Pull element
from mounting holes.
Reassemble in reverse order.
REPLACE SOLENOID
Disconnect brewer from electric power. Turn
OFF
and
disconnect water supply from brewer inlet fitting.
Remove two screws holding solenoid access door in place.
Remove two screws holding solenoid bracket to door. Unscrew
inlet fitting cap and remove solenoid from door.
Remove wiring from solenoid.
Remove tubing from old solenoid and transfer to new solenoid.
Reassemble in reverse order.
13
915
76294
Owner
s M
anual for
8783M
CD