32 HDE-4S-PRO
Instruction Manual
Event Log Destination:
is the IP address of the remote server, to which Syslog sends the activities recorded by encoder
for monitoring and troubleshooting purposes. The factory default value is 172.16.70.2.
Log Destination Port #:
is the Event Log Destination port to which a duplicate of the error messages created by the
unit can be forwarded for monitoring and troubleshooting purposes. The factory default value, which cannot be
modified, is 514.
Time Server IP:
is the IP address for the Time Server from where the unit can obtain its clock reference (see Section 6.9
for details). The factory default value is 172.16.70.2.
Syslog Errors:
is to enable/disable encoder to forward error messages (in red font) to an SNMP syslog. The factory
default value is disabled.
Syslog Informational:
is to enable/disable encoder to forward information messages (in blue font) to an SNMP syslog.
The factory default value is disabled.
Syslog Feedback:
is to enable/disable encoder to forward feedback or confirmation messages (in green font) to an SNMP
syslog. The factory default value is disabled.
Remember to click on the SAVE button to apply the new values/configurations.