2
FAxM Series
Instruction Manual
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE
NOTE TO CATV SYSTEM INSTALLER
!
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning flash with arrow-
head symbol within an equilateral
triangle is intended to alert you
to the presence of uninsulated
“dangerous voltage” within the
product’s enclosure that may be
of sufficient magnitude to consti-
tute a risk of electrical shock to
persons.
The exclamation point within an
equilateral triangle is intended
to alert you to the presence of
important operating and main-
tenance (servicing) instructions
in the literature accompanying
the product.
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER FROM THIS UNIT.
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Unpacking and Handling
Each unit is shipped with all equipment assembled, wired, factory tested, and then packaged in an appropriate
shipping container.
Ensure that all accessories are removed from the container and packing material before they are discarded.
Mechanical Inspection
Inspect the front and rear of the equipment for shipping damage. Make sure the equipment is clean, and no wires,
cables, or connectors are broken, damaged or loose.
Precautions
Adherence to the initial installation precautions outlined in the Table below will help prevent problems arising
during the installation and future maintenance of the unit.
Damage in Shipment
Should any damage be discovered after unpacking the unit, immediately file a claim with the carrier. A full report
of the damage shall be made and a copy forwarded to Blonder Tongue Laboratories Inc. The company will then
advise what disposition is to be made of the equipment.
PRECAUTIONS
REQUIREMENTS
Avoid Heat Buildup
Allow (1) EIA rack space (1
3/4
") between powered headend products in the equipment
racks.
Ensure easy access to rack wiring.
Allow a minimum of 18 inches behind the equipment rack(s)
Facilitate servicing and maintenance.
Allow a minimum of 36” of clearance in front of the equipment rack(s).
Avoid direct heating or air conditioning.
If unavoidable, use deflector plates.
AC power source outlets.
Locate equipment near sufficient outlets to provide power for test equipment and power
tools.
Rack Support.
Make certain rack supports are sufficiently rigid to support racks.
Building leakage.
Beware of dripping water onto equipment from leaky roofs, waveguide roof entries, and
cold water pipe condensations.
Table 1 - Installation Precautions Table
This reminder is provided to call the CATV System Installer’s attention that the cable distribution
system should be grounded (earthed) in accordance with ANSI/NFPA 70, the National Electrical Code
(NEC), in particular Section 820.93, Grounding of Outer Conductive Shield of a Coaxial Cable.
Returning Product for Repair or Credit
A Return Material Authorization (RMA) Number is required on all products returned to
Blonder Tongue, regardless if the product is being returned for repair or credit.
Before
returning product, please contact the Blonder Tongue Service Department at 1-800-523-6049, Ext. 4256
or visit our website: www.blondertongue.com for further information.