II. SPECIFICATIONS
BTEA SERIES EDFA:
Item
Min.
Typ.
Max.
Operating Wavelength (nm)
1540
1550
1560
Signal Input Power (dBm)
-2
3
10
Signal Output Power (dBm)
BTEA-CO-B16-116 (1 output)
16.0
16.2
16.5
BTEA-CO-B19-119 (1outputs)
19.0
19.2
19.5
BTEA-CO-B19-216 (2outputs)
16.0
16.2
16.5
BTEA-CO-B23-219 (2outputs)
19.0
19.2
19.5
BTEA-CO-B23-416 (4outputs)
16.0
16.2
16.5
BTEA-CO-B26-419 (4outputs)
19.0
19.2
19.5
BTEA-CO-B26-816 (8outputs)
16.0
16.2
16.5
Number of output port
1~8
Noise Figure @ 1550nm, 0dBm input (dB)
5.0
Input/Output Isolation (dB)
30
Pump Leakage to Input/Output (dBm)
-30
Input/Output Return Lose (dB)
50
Input/Output Interface
SA /FA or Customer Specified
Operating Temperature (
C)
0 ~ 50
Storage Temperature (
C)
-25 ~ 70
Relative Humidity (Non Condensing)
5% ~ 95%
Voltage
90 ~ 240VAC or 36 ~ 60VDC
Dimension
434mm (W)
260 (D)
44 (H)
Installation
Standard 19” 1U Rack Mounted