Blonder tongue BTEA-CO-B16-116-SA User Manual Download Page 1

 

                                       

                                         

U

U

s

s

e

e

r

r

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

B

T

T

E

E

A

A

 

 

S

S

e

e

r

r

i

i

e

e

s

s

 

 

E

E

r

r

b

b

i

i

u

u

m

m

 

 

D

D

o

o

p

p

e

e

d

d

 

 

F

F

i

i

b

b

e

e

r

r

 

 

A

A

m

m

p

p

l

l

i

i

f

f

i

i

e

e

r

r

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

R

e

e

v

v

.

.

0

0

0

0

5

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

A

u

u

g

g

u

u

s

s

t

t

 

 

1

1

8

8

,

,

2

2

0

0

0

0

9

9

 

 

 

BTEA Series 

User Manual 

 

 

 

 

 

BTEA Series EDFA 

BTEA-CO-B16-116-SA           BTEA-CO-B19-119-SA 
BTEA-CO-B19-216-SA        BTEA-CO-B23-416-SA            
BTEA-CO-B23-219-SA        BTEA-CO-B26-816-SA            
BTEA-CO-B26-419-SA 

 

Summary of Contents for BTEA-CO-B16-116-SA

Page 1: ... op pe ed d F Fi ib be er r A Am mp pl li if fi ie er r R Re ev v 0 00 05 5 A Au ug gu us st t 1 18 8 2 20 00 09 9 BTEA Series User Manual BTEA Series EDFA BTEA CO B16 116 SA BTEA CO B19 119 SA BTEA CO B19 216 SA BTEA CO B23 416 SA BTEA CO B23 219 SA BTEA CO B26 816 SA BTEA CO B26 419 SA ...

Page 2: ...CONTENTS I INTRODUCTION 1 II SPECIFICATIONS 3 III OPERATION INSTRUCTIONS 4 IV ERROR AND MAINTENANCE 6 V SAFETY PRECAUTIONS 7 SNMP NETWORK MANAGEMENT USER GUIDE 8 ...

Page 3: ...he desired specifications for its overall performance The Structure Diagram of EDFA Gain module of EDFA External Control System This part is necessary to the EDFA to ensure the gain module is working in optimum state Controlled by micro processor it monitors the states of the gain module such as pump power pump temperature pump current input and output power and adjusts all the parameters to ensur...

Page 4: ...CO B16 116 SA BTEA CO B19 119 SA BTEA CO B19 216 SA BTEA CO B23 416 SA BTEA CO B23 219 SA BTEA CO B26 816 SA BTEA CO B26 419 SA Rear panel of BTEA series POWER SWITCH FAN POWER FUSE OUTPUT INPUT RJ 45 LABLE GROUND 2 OUTPUTS 4 OUTPUTS AC POWER 90 240VAC or DC POWER 36 60VDC BTEA CO B16 116 1 output BTEA CO B19 119 1 output BTEA CO B19 216 2 output BTEA CO B23 219 2 outputs BTEA CO B23 416 4 outputs...

Page 5: ...B19 216 2outputs 16 0 16 2 16 5 BTEA CO B23 219 2outputs 19 0 19 2 19 5 BTEA CO B23 416 4outputs 16 0 16 2 16 5 BTEA CO B26 419 4outputs 19 0 19 2 19 5 BTEA CO B26 816 8outputs 16 0 16 2 16 5 Number of output port 1 8 Noise Figure 1550nm 0dBm input dB 5 0 Input Output Isolation dB 30 Pump Leakage to Input Output dBm 30 Input Output Return Lose dB 50 Input Output Interface SA FA or Customer Specifi...

Page 6: ...dicate as follows POWER power indicator Shows green when the power is on PUMP STATUS pump states indicator Shows green when the pump works in normal states and shows red when the pump is not working The pump will be shut down in these cases input power is less than default setting pump temperature is higher than 35 C pump current value exceeds its limit value INPUT POWER input power indicator Show...

Page 7: ... nu ua al l O Op pt ti ic ca al l A Am mp pl li if fi ie er r R Re ev v 0 00 05 5 P Pa ag ge e5 5o of f1 15 5 4 LCD Display The LCD screen in the front panel is to show the detail information of EDFA Press the blue key to show these parameters circularly ...

Page 8: ...than default setting the INPUTSTATUS LED will show red In this case the pump will turn off and the EDFA will stop working 3 Environmental temperature is suitable for EDFA working in its normal state The working temperature for EDFA is from 0 C to 50 C Too high environment temperature will cause TEC current exceed its limit thus OVERTEMP LED will show red to give a warning When pump temperature exc...

Page 9: ...range infrared light may be over 16dBm 40 mW Therefore to avoid damaging your eyes please do not look into the output port of the EDFA directly Please do not clean the output connector when the pump laser is on in order not to damage the connector The fiber amplifier is fine equipment Therefore please do not open the case of the amplifier to avoid damaging the internal component devices Opening th...

Page 10: ... GUIDE Accessing server management 1 Start the web browser and type the URL http xxx xxx xxx xxx Note xxx xxx xxx xxx is the default IP address 2 The login screen of EDFA Network Management System is shown below Fig 6 1 3 The default Server Management user name is admin and it is necessary to log in with this name for full access to the server 4 Use the default password snmpedfa to log in ...

Page 11: ...Pa ag ge e9 9o of f1 15 5 Management interface summary When the network manager of EDFA logs in the web browser displays the following main interface MAIN INTERFACE Fig 6 2 system menu Clicking on the different system menu will change the displaying area screen System Info sub menu is shown here Fig 6 3 System Info sub menu explaination ...

Page 12: ...ter Netmask The subnet mask of the IP address specified above Trap IP Address IP address of the trap host to which a trap is issued Community Name read The read community to which the system belongs Community Name write The write community to which the system belongs Stat Scan data elements status Com Abnormal expresses unreliable or useless data status Com Normal expresses reliable or useful data...

Page 13: ...ng parameters in a table Fig 6 5 Note The EDFA management system can monitor up to three pumps it can automatically identifies the number of pumps if the parameters of a pump are all zero then the pump is not present in the equipment Status Click Status to view EDFA status Fig 6 6 Status items are explained as follows Power Normal power supply of EDFA is normal Pump status Normal Pump works in nor...

Page 14: ...5 C Over temp Abormal Pump TEC current is higher than limit or pump temperature is above 35 C Remote Connected The amplifier is connected with network management system Remote Disconnected The amplifier is not connected with network management system System set sub menu is shown below Fig 6 7 System Set sub menu explaination Pump Click Pump to view the pump setting Pump Current Adjust In Fig 6 8 t...

Page 15: ...l li if fi ie er r R Re ev v 0 00 05 5 P Pa ag ge e1 13 3o of f1 15 5 Increasing or reducing the pump current may decrease other performance of EDFA like NF Be cautious to operate Fig 6 8 Fig 6 9 Fig 6 10 Turn on off the pump In fig 6 8 click the button to open pump click the button to close pump ...

Page 16: ...e system enter into force upon setting SNMP Community Name SNMP read write communities to which the system belongs The default name is CON When the setting has been successfully completed reset your system Note If Snmp trap address setting and SNMP community name options are succeeded to set up setting success will appear Fig 6 11 Basic Network setup and user related settings Network Setting Click...

Page 17: ... Se er ri ie es s U Us se er r M Ma an nu ua al l O Op pt ti ic ca al l A Am mp pl li if fi ie er r R Re ev v 0 00 05 5 P Pa ag ge e1 15 5o of f1 15 5 Fig 6 12 Log out Operator exit system and return to log in window ...

Page 18: ...ugh ping orders 3 Check your IP setting IP address sub netmask and broadcasting address make sure it is correct If SNMP administrative station is in different networks make sure to establish a suitable gateway IP address 4 If SNMP can t communicate to management server and SNMP agent please check SNMP parameter 5 Check read community and write community 6 If traps are not received check whether th...

Reviews: