3.6 Timer function

The timer function module provides a timer for each of 
both cooking zones of a Touch Control. 

All timers are countdown timers. The optional setting range is between 1 and 
99 minutes. After the timer is set, it counts backwards in minute steps down 
to 0. Then, a visible and audible alarm signal is emitted.  
As for a cooking zone related mode, the corresponding cooking zone is 
disconnected automatically upon expiry of the timer. 

Before operating a timer, the Touch Control is to be switched into at least 
standby mode via the ON/OFF key. Switching off the Touch Control disables 
the cooking zone related timer, programmed egg timers continue running. 

3.7 Lo Temp – function (presently only for induction)

The Lo Temp function is supposed to keep cooked meals 
warm on top of a  cooking zone. 

The operator can activate it by selecting a cooking stage 

between 0 and 1 resulting in both cooking zone displays to show the symbol 
„Lo“ (see above). If the cooking stages are reduced by holding the minus 
key, the Low-temp cooking stage is stopped. Another touch would be 
necessary to switch to stage 0. 

3.8 Booster activation

  All induction cooking zones have a booster function.    

The booster allows a particularly speedy heating of the food stuffs, 
thus, helping the operator to save time. 

No booster key available in the system: 

Cooking zone must be set to the highest possible level : 
Release of „+“ or „-“ key. Another touch on the „+“ key activates the booster 
function. The corresponding cooking stage display shows a static „P“ symbol. 

11

Summary of Contents for MIS 3200

Page 1: ...DoPLno Induction Touch Control Domino Induktion Sensorstaten MIS 3200 X QVWUXFWLRQV 0DQXDOV HEUDXFKVDQOHLWXQJ FR DE PT FL DA...

Page 2: ......

Page 3: ...ENGLISH DOMINO INDUCTION TOUCH CONTROL OPERATING INSTRUCTIONS BOOK GB...

Page 4: ......

Page 5: ...struction for the user 6 2 3 Key panels 8 3 FUNCTIONS 9 3 1 ON OFF switching of cooking zone 9 3 2 Cooking levels 10 3 3 Residual heat indication 10 3 4 Key lock 10 3 5 Break indication 10 3 6 Timer f...

Page 6: ...2...

Page 7: ...earth connection system The material and glues used for the kitchen unit must resist a temperature of min 100 C WARNING Before any operation Disconnect the hob from the electrical mains Make sure tha...

Page 8: ...might cause damage Salt sugar and sand scratch ceramic glass Do not use the hob as a work surface or for placing anything Hard or pointed objects accidentally falling on the hob may cause damage Do no...

Page 9: ...l wood or the like must be inserted between the cook top and the space below This partition must be at least 10 mm from the underside of the cook top tray Positioning Spread the sealing agent all the...

Page 10: ...sult is a fast cost effective and accurate cooking method This type of cook top can be used with enamelled steel or stainless steel pans it is not suitable for use with glass ceramic or aluminium pans...

Page 11: ...ive sponges or irritating chemical detergents such as oven sprays or spot removers Protection against excess temperature The generator as well as the coils have integrated functions protecting against...

Page 12: ...crease cooking level 4 Minus reduce cooking level 5 Timer Cooking zone special function Timer dual circuit triple circuit if no timer available 11 Power LED 12 LED general special function 1 Cooking z...

Page 13: ...minus keys while in standby or active mode unless the cooking zone had not been set by the optional timer programming see 2 13 Starting position Cooking zone is in OFF mode Display 0 If starting out...

Page 14: ...sors along the heat sink protect the electronics itself against overheating This causes the P symbol to flash on the relevant display indicating that the booster request cannot be dealt with currently...

Page 15: ...ning 3 7 Lo Temp function presently only for induction The Lo Temp function is supposed to keep cooked meals warm on top of a cooking zone The operator can activate it by selecting a cooking stage bet...

Page 16: ...ated at radiant heating element or reported via LIN induction 1 sec all 2 Er31 Invalid or no configuration available 1 sec induction 3 Er47 Interference on LIN Bus A necessary participant does not res...

Page 17: ...soon as indicated by at least one induction cooking zone Induction 7 E5 Error mains voltage signal Induction 8 E7 Sub LIN error between filter and power board Induction 9 E6 5V short circuit with pow...

Page 18: ...ge 220 240 V nominal frequency 50 60 Hz The power of a power board is limited to 3700 W Use only rubber cable type H05VV F the cross setion on the wires must be 3x1 5mm Stand by consumption of the gen...

Page 19: ...when the second temperature limit is reached Start lower speed 45 C Start higher speed 55 C Temperature control of cooking zones The residual heat indicator contributes to the protection of the user T...

Page 20: ...Fig 1 Fig 2 Fig 3 16...

Page 21: ...Fig 4 17...

Page 22: ...Fig 5 Fig 6 18...

Page 23: ...FRAN AIS DOMINO INDUCTION COMMANDE SENSITIVE MANUEL D UTILISATION FR...

Page 24: ......

Page 25: ...2 3Bandeau de commande 29 3 FONCTIONS 30 3 1Commande Marche Arr t de la zone de cuisson 30 3 2 Niveaux de cuisson 31 3 3 Indication de chaleur r siduelle 31 3 4 Verrouillage des touches 31 3 5 Indicat...

Page 26: ...22...

Page 27: ...ctrique doit tre muni d un syst me d installation lectrique adapt de mise la terre Les mat riaux et colles utilis es pour l l ment de cuisine doivent r sister une temp rature minimale de 100 C AVERTIS...

Page 28: ...fabricant Ne jamais poser de casseroles ou po les chaudes sur le bandeau de commande la zone d affichage ou le cadre Ceci pourrait occasionner des dommages Le sel le sucre et le sable rayent la surfa...

Page 29: ...r ET LA PLAQUE DE CUISSON VITROC RAMIQUE DOIVENT TRE ISOL S CORRECTEMENT de mani re ce que la chaleur manant du four mesur e sur le c t droit du dessous de la plaque de cuisson soit inf rieure 60 C La...

Page 30: ...l g rement sup rieur celui de la zone chauffante Le fond des r cipients ne doit pas tre rugueux afin d viter de rayer la surface chauffante Utiliser uniquement des casseroles et po les dont le fond es...

Page 31: ...e cuisson si vous observez la moindre fissure sur la surface de cuisson d connecter l alimentation lectrique imm diatement Entretien Commencer par nettoyer les r sidus et la graisse de la surface de c...

Page 32: ...quantit s en particulier il se peut qu aucune une plusieurs ou toutes les touches puissent donc tre confondues et activ es bri vement ou de mani re permanente cet gard les salissures peuvent entra ne...

Page 33: ...uisson 5 Fonction Minuterie Zone de cuisson sp ciale Minuterie double circuit triple circuit s il n y a pas de minuterie 11 Voyant lumineux de puissance 12 Voyant lumineux fonction sp ciale g n rale 1...

Page 34: ...Marche Arr t d une zone de cuisson Mettre en marche Une zone de cuisson peut tre activ e directement par les touches plus moins correspondantes en mode stand by ou actif sauf si la zone de cuisson n a...

Page 35: ...n En principe l induction est une m thode de s curit intras que Le syst me lectronique comprend des capteurs de temp rature pour chaque zone de cuisson situ e en dessous de la surface vitroc ramique a...

Page 36: ...nutes jusqu 0 Ensuite un signal visible et audible sera mis En ce qui concerne le mode li une zone de cuisson la zone correspondante est automatiquement d connect e l expiration de la minuterie Avant...

Page 37: ...L cran de la phase de cuisson correspondant indique un symbole statique P Pour des raisons de s curit la fonction d appoint de chaque zone de cuisson n est disponible que pendant 10 min Le fait d app...

Page 38: ...niveau 10 sec tous Erreurs sp cifiques aux zones de cuisson Priorit Affichage Description Syst me 1 E5 Erreur de communication du Bus LIN Tr s probablement diagnostiqu e par l unit de commande sensit...

Page 39: ...ux de l impulsion du r seau d alimentation Induction 13 E9 D tecteur bobine d fectueux Induction 14 E2 D tecteur bobine surchauff diagnostiqu e par induction Induction 15 Blitz Fonctionnement continu...

Page 40: ...Diam tre Puissance nominale Puissance d appoint 145 mm 1400 W 1800 W 210 mm 2300 W 3200 W diameter nominal power boost power Commande du ventilateur Refroidissement int gr du g n rateur Le refroidiss...

Page 41: ...L indication de chaleur r siduelle affiche un H lorsqu une certaine temp rature est atteinte sur la surface vitroc ramique Elle s teint de nouveau d s que la temp rature descend en dessous d un certai...

Page 42: ...Fig 1 Fig 2 Fig 3 Pose du joint Marron Jaune vert Bleu Ligne Terre Neutre R SEAU D ALIMENTATION LECTRIQUE Cordon d alimentation 38...

Page 43: ...Fig 4 X 150mm MIN W 50mm MIN A 200cm 2 MIN Y Cloison 39...

Page 44: ...Fig 5 Fig 6 G N RATEUR R cipient dont le fond est en mat riau ferromagn tique Champ magn tique Doucement dans la vitre c ramique Bobine en spirale d Archim de 40...

Page 45: ...DEUTSCH DOMINO INDUKTION SENSORTASTEN BEDIENUNGSANLEITUNG DE...

Page 46: ......

Page 47: ...stallateur 47 2 2Hinweise f r den Benutzer 48 2 3Bedienfeld 50 3 FUNKTIONEN 51 3 1Kochzone ein und ausschalten 51 3 2Kochstufen 52 3 3Restw rmeanzeige 52 3 4Tastensperre 52 3 5Pause 53 3 6Timer 53 3 7...

Page 48: ...44...

Page 49: ...Materialien und Klebeverbindungen m ssen einer Temperatur von mindestens 100 C standhalten WARNUNG Vor der Ausf hrung jedweder Arbeiten Trennen Sie das Kochfeld von der Stromversorgung Vergewissern Si...

Page 50: ...ngen f hren Salz Zucker und Sand verkratzten die Glaskeramik Missbrauchen Sie das Kochfeld nicht als Arbeitsplatte oder zum Abstellen von Gegenst nden Harte und spitze Gegenst nde k nnen das Kochfeld...

Page 51: ...eldes befindet muss das Kochfeld durch eine isolierende Schicht aus einem geeigneten Material z B Holz vom Stauraum darunter getrennt werden Zwischen Stauraum und Unterkante des Kochfeldes muss ein Ab...

Page 52: ...ochfeldes k hl weil sich lediglich das Kochgeschirr aufheizt Das Ergebnis ist eine schnelle kosteng nstige und saubere Zubereitung Sie k nnen Ihr Kochfeld mit emailliertem Stahl oder Edelstahlgeschirr...

Page 53: ...ressive Chemikalien wie Ofensprays oder Fleckentferner Schutz gegen berm ige Erw rmung Sowohl Generator als auch Spulen verf gen ber integrierte Schutzschaltungen gegen berm ige Erw rmung Im Inneren d...

Page 54: ...e Pause Doppelzone Dreifachzone 3 Plus Kochstufe erh hen 4 Minus Kochstufe vermindern 5 Timer Kochzone Spezialfunktion Timer Doppelzone Dreifachzone wenn kein Timer verf gbar 11 Betrieb LED 12 Spezial...

Page 55: ...tensperre siehe 2 10 aktiviert wurde Kochzone ein und ausschalten Einschalten Eine Kochzone kann direkt ber die entsprechenden Plus Minustasten eingeschaltet werden bei aktiven Sensortasten oder im St...

Page 56: ...nduktionskochzonen Im Prinzip arbeitet das Induktionsverfahren eigensicher Die Induktionselektronik berwacht jede Kochzone mit Hilfe von Temperatursensoren die sich unterhalb der Glaskeramik befinden...

Page 57: ...f r eine Kochzone eingestellt wurde wird die jeweilige Kochzone nach Ablauf des Timers automatisch ausgeschaltet Bevor Sie einen Timer einstellen k nnen m ssen Sie die Sensortasten ber die Ein Austas...

Page 58: ...en Wenn Sie bei aktivierter Schnellkochfunktion die Minustaste dr cken wird die Schnellkochfunktion abgeschaltet Das Dr cken der Taste hat keinen Effekt Pro Induktionschaltung kann eine maximale Leist...

Page 59: ...r Controller Pr fsummenfehler Induktion 3 E5 Falsche Programmierungsoptionen Induktion 4 E5 EEPROM Pr fsummenfehler Induktion 5 E5 Unklare EEPROM Daten Induktion 6 U400 400 Volt Unterspannung wird zu...

Page 60: ...schen E6 Leistungsplatine tauschen E7 Unbekannter Fehler kann nicht eindeutig identifiziert werden E9 Temperatursensor tauschen 4 Technische Daten Nennspannung und Strom Nennspannung 220 240 V Nennfre...

Page 61: ...ird und schaltet auf eine h here Stufe wenn eine zweite Temperaturgrenze berschritten wird Schwellwert niedrige Geschwindigkeit 45 C Schwellwert hohe Geschwindigkeit 55 C Kochzonen Temperatursteuerung...

Page 62: ...Abbildung 1 Abbildung 2 Abbildung 3 Dichtung anbringen Braun Gelb gr n Blau Phase Erde Nullleiter NETZSTROMVERSORGUNG Netzkabel 58...

Page 63: ...Abbildung 4 X Mind 150mm W Mind 50mm A Mind 200cm 2 Y Teilung 59...

Page 64: ...Abbildung 5 Abbildung 6 GENERATOR Topf mit ferromagnetischem Boden Magnetfeld Glaskeramik Archimedes Spule 60...

Page 65: ...PORTUGU S DOMINO INDUCTION CONTROLO DIGITAL MANUAL DE INSTRU ES DE FUNCIONAMENTO PT...

Page 66: ......

Page 67: ...2 3Pain is das teclas 70 3 FUN ES 71 3 1Comuta oON OFF LIGAR DESLIGAR da rea de cozedura 71 3 2 N veis de cozedura 72 3 3 Indica o do calor residual 72 3 4 Bloqueio 72 3 5 Indica o de interrup o 73 3...

Page 68: ...64...

Page 69: ...ateriais utilizados para a unidade de cozinha devem resistir a temperaturas de no m nimo 100 C AVISO Antes de qualquer opera o Desligue a placa das tomadas el ctricas Certifique se que a placa esteja...

Page 70: ...causar danos Sal a car e areia riscam a vitrocer mica N o utilize a placa como uma superf cie de trabalho ou para colocar algo Objectos duros ou pontiagudos que caiam acidentalmente na placa podem ca...

Page 71: ...or debaixo da placa deve ser inserida uma divis ria feita de material isolante madeira ou afins entre a placa e o espa o inferior Esta divis o deve estar pelo menos a 10 mm da parte inferior do tabule...

Page 72: ...tacho por isso a superf cie da placa permanece fria mas o tacho aquece O resultado um m todo de cozedura r pido econ mico e preciso Este tipo de placa pode ser utilizada com tachos de a o esmaltado ou...

Page 73: ...u micos irritantes tais como os pulverizadores para fornos ou removedores de salpicos Protec o contra temperatura excessiva O gerador bem como os discos possuem fun es integradas de protec o contra te...

Page 74: ...s reduz o n vel de cozedura 5 Temporizador rea de cozedura especial fun o Temporizador circuito duplo circuito triplo se n o existir temporizador dispon vel 11 LED de alimenta o 12 LED da fun o especi...

Page 75: ...ea de cozedura Comuta o ON LIGAR Uma rea de cozedura pode ser directamente activada atrav s das teclas correspondentes mais menos enquanto no modo de espera ou no modo activo a menos que a rea de coze...

Page 76: ...ndu o funciona intrinsecamente segura A electr nica de indu o fornece sensores de temperatura em cada rea de cozedura estando localizados por debaixo da superf cie de vitrocer mica para monitorar temp...

Page 77: ...ionado de rea de cozedura a rea de cozedura correspondente automaticamente desligada quando expirar o temporizador Antes de funcionar com um temporizador o Controlo Digital deve ser comutado para pelo...

Page 78: ...cada rea de cozedura est apenas dispon vel por um per odo limitado de 10 min Ao pressionar a tecla menos enquanto a fun o de aquecimento est activa faz com que a mesma seja desligada Ao pressionar a t...

Page 79: ...icado como Er47 Indu o 2 E5 Flash de controlador defeituoso Verifica o total incorrecta Indu o 3 E5 Op es de programa o erradas Indu o 4 E5 Verifica o total de EEPROM incorrecta Indu o 5 E5 Dados da E...

Page 80: ...permanente m nimo 10 seg ap s desligar uma rea de cozedura todos 16 Blitz Funcionamento permanente m nimo 10 seg sem desligar uma rea de cozedura todos E2 Sobreaquecimento E5 Substituir filtro do quad...

Page 81: ...Di metro Pot ncia nominal Pot ncia para aquecimento r pido 145 mm 1400 W 1800 W 210 mm 2300 W 3200 W di metro pot ncia nominal pot ncia de aumento Controlo de ventoinha Refrigera o integrada do gerad...

Page 82: ...O indicador de calor residual liga com um H logo que seja alcan ada determinada temperatura por debaixo da vitrocer mica E desliga de novo logo que a temperatura des a para um determinado n vel Limia...

Page 83: ...Fig 1 Fig 2 Fig 3 Aplica o do vedante Castanho Amarelo verde Azul Linha Terra Neutro FORNECIMENTO EL CTRICO Cabo de alimenta o 79...

Page 84: ...Fig 4 X 150mm MIN W 50mm MIN A 200cm 2 MIN Y Parti o 80...

Page 85: ...Fig 5 Fig 6 GERADOR Tacho com fundo de material ferromagn tico Campo magn tico Insignificante em vitrocer micas Disco em espiral de Arquimedes 81...

Page 86: ...82...

Page 87: ...NEDERLANDS DOMINO INDUCTIE TIPTOETSBEDIENING GEBRUIKSAANWIJZING NL...

Page 88: ......

Page 89: ...es voor de gebruiker 90 2 3Toetspanelen 92 3 FUNCTIES 93 3 1IN UIT schakelen van de kookzone 93 3 2 Kookniveaus 94 3 3 Restwarmte aanduiding 94 3 4 Toetsvergrendeling 94 3 5 Verbreking aanduiding 94 3...

Page 90: ...86...

Page 91: ...st zijn met een geschikt aardaansluitingssysteem Het materiaal en de lijm die gebruikt werd voor de keukenkast moeten bestand zijn tegen een temperatuur van minstens 100 C WAARSCHUWING Voor de werking...

Page 92: ...zand kunnen de keramische plaat krassen Gebruik de kookplaat niet als een werkoppervlak of om iets op te plaatsen Harde objecten of objecten met punten die per ongeluk op de kookplaat vallen kunnen sc...

Page 93: ...een toegankelijke kastruimte is onder de kookplaat moet een scheidingsplaat van isolerend materiaal hout of iets dergelijks geplaatst worden tussen de kookplaat en de ruimte eronder Deze scheidingspla...

Page 94: ...e brander dezelfde grootte hebben De inductie kookmethode brengt snel de energie over die nodig is om rechtstreeks in de pot te koken zodat het oppervlak van de kookplaat koud blijft maar de pot opwar...

Page 95: ...lijke schade aan het oppervlak van de kookplaat te vermijden Gebruik nooit schuursponzen of irriterende chemische detergenten zoals ovenspray of ontvlekkers Bescherming tegen te hoge temperatuur De ge...

Page 96: ...ergrendeling verbreken dubbele kring drievoudige kring 3 Plus kookniveau verhogen 4 Min kookniveau verlagen 5 Timer Kookzone speciaal functie Timer dubbele kring drievoudige kring indien geen timer be...

Page 97: ...kzone Aanschakelen Een kookzone kan direct worden geactiveerd via de overeenkomstige plus min toetsen terwijl in de stand Stand by of actief tenzij de kookzone niet werd ingesteld via het optionele ti...

Page 98: ...Meer temperatuursensors langs de warmteafvoer beschermt de elektronica zelf tegen oververhitting Dit doet het symbool P knipperen op het relevante display en geeft aan de de boostervraag momenteel ni...

Page 99: ...elt de aan de kookzone verwante timer uit de geprogrammeerde eiertimers blijven werken 3 7 Lage Temp functie enkel aanwezig voor inductie De functie lage temperatuur wordt verondersteld gekookte maalt...

Page 100: ...lgemene fouten Priorit eit Display Omschrijving Tijdsverl oop Systee m 1 U400 Blinde verbinding met de bediening Direct in uitstralend verwarmingselement of gemeld via LIN inductie 1 sec alle 2 Er31 O...

Page 101: ...400 Overvoltage 400V wordt algemene fout bij tiptoets van zodra als aangegeven door minstens n inductiekookzone Inductie 7 E5 Fout netvoltagesignaal Inductie 8 E7 Sub LIN fout tussen filter en voeding...

Page 102: ...0 V nominale frequentie 50 60 Hz Het vermogen van een voedingsbord is beperkt tot 3700 W Gebruik enkel een rubberen kabeltype H05VV F de dwarsdoorsnede op de draden moet 3x1 5mm zijn Stand by consumpt...

Page 103: ...over op een hogere snelheid wanneer de tweede temperatuurlimiet bereikt is Start lagere snelheid 45 C Start hogere snelheid 55 C Temperatuurregeling van kookzones De restwarmte aanduiding draagt bij t...

Page 104: ...Afb 1 Afb 2 Afb 3 De dichting toepassen Bruin Geel groen Blauw Lijn Aarde Neutraal STROOMTOEVOER Netsnoer 100...

Page 105: ...Afb 4 X 150mm MIN W 50mm MIN A 200cm 2 MIN Y Partitie 101...

Page 106: ...Afb 5 Afb 6 GENERATOR Pot met bodem in ferromagnetisch materiaal Magnetisch veld Traag in keramisch glas Spoel zoals spiraal van Archimedes 102...

Page 107: ...DANSK DOMINO INDUKTION TOUCH BETJENING BETJENINGSVEJLEDNING DA...

Page 108: ......

Page 109: ...dning til brugeren 110 2 3 Taster p betjeningspanelet 112 3 FUNKTIONER 113 3 1 T ND SLUK for kogezonen 113 3 2 Kogeniveauer 114 3 3 Indikation for restvarme 114 3 4 Tastel s 114 3 5 Pause indikation 1...

Page 110: ...106...

Page 111: ...g limen der skal bruges til k kkenenheden skal kunne modst en temperatur p min 100 C ADVARSEL Inden betjening Afbryd komfurpladen fra str mforsyningen S rg for at komfurpladen er kold Fors g ikke selv...

Page 112: ...ske glas Undlad at bruge kogepladen som arbejdsbord eller til at placere ting p H rd eller spidse genstande der ved et uheld falder ned p komfuret kan for rsage skade Undlad at placere disse genstande...

Page 113: ...under komfurpladen skal der inds ttes en adskillelse lavet af isolerende materiale tr eller lign mellem komfurpladen og arealet nedenunder Denne adskillelse skal v re mindst 10 mm fra undersiden af ko...

Page 114: ...old men gryden panden varmes op Resultatet er en hurtig omkostningsbesparende madlavningsmetode Den type bordkomfur kan bruges med emaljerede st l eller rustfri st lgryder Det er ikke egnet til glas k...

Page 115: ...om f eks ovnspray eller pletfjernere Beskyttelse mod for h j temperatur B de generatoren og varmespiralen har integrerede funktioner der beskytter mod for h j temperatur Inde i str mtavlen er der en t...

Page 116: ...Plus for ger kognings niveau 4 Minus reducerer kognings niveau 5 Timer kogezone speciel funktion Timer tokreds trekreds hvis der ikke er nogen timer tilg ngelig 11 Effekt LED 12 LED generel specialfun...

Page 117: ...tilsvarende plus minus taster n r den er i standby eller aktiv tilstand medmindre kogezonen ikke er blevet indstillet af den valgfri timer programmering se 2 13 Startposition Kogezone er SLUKKET Disp...

Page 118: ...ere temperatursensorer langs med k lelegemet beskytter selve elektronikken mod overophedning Dette f r P symbolet til at blinke p det relevante display hvilket angiver at booster anmodningen ikke kan...

Page 119: ...t k re 3 7 Lo Temp funktion pt kun for induktion Lo temp funktionen er beregnet til at holde maden varm p en kogezone Brugeren kan aktivere den ved at v lge et kogetrin mellem 0 og 1 hvilket resultere...

Page 120: ...le varme element eller rapporteret via LIN induktion 1 sek alle 2 Er31 Forkert eller ingen konfiguration tilg ngelig 1 sek induktion 3 Er47 Interferens p LIN Bus En n dvendig deltager svarer ikke 1 s...

Page 121: ...indikeret ved mindst en induktionskogezone Induktion 7 E5 Signal for fejl i netsp nding Induktion 8 E7 Sub LIN fejl mellem filter og str mtavle Induktion 9 E6 5V kortslutning med str mtavle Induktion...

Page 122: ...0 240 V nominel frekvens 50 60 Hz Str mmen p en str mtavle er begr nset til 3700 W Brug kun gummiledning type H05VV F ledningernes tv rsnit skal v re 3 x 1 5 mm Generatorens forbrug ved stand by Maks...

Page 123: ...n r den n ste temperaturgr nse n s Starter lav hastighed ved 45 C Starter h j hastighed ved 55 C Temperaturstyring af kogezoner Indikatoren for restvarme medvirker til at beskytte brugeren Indikatione...

Page 124: ...Fig 1 Fig 2 Fig 3 P s tning af t tning Brun Gul gr n Bl Ledning Jord Nul STR MTIL F RSEL Str mledning 120...

Page 125: ...Fig 4 Skillev g 121...

Page 126: ...Fig 5 Fig 6 GENERATOR Kasserolle med bund af ferromagnestisk materiale Magnetisk omr de Langsomt i keramisk glas Spole til Archimedes spiral 122...

Page 127: ...danking moet worden uitgevoerd in overeenstemming met de plaatselijke milieuvoorschriften voor afvalverwerking Voor nadere informatie over de behandeling terugwinning en recycling van dit product word...

Page 128: ...zen WEEE Zaji t n m spr vn likvidace tohoto v robku pom ete zabr nit p padn m negativn m d sledk m na ivotn prost ed a lidsk zdrav ke kter m by nevhodnou likvidac tohoto v robku mohlo doj t Symbol na...

Page 129: ......

Page 130: ...H01A4000...

Reviews: