Operation
18
Single Speed Blower with Cavity Lights
LIGHTS
ON
OFF
COOL
DOWN
MAN
AUTO
BLOWER
ON
OFF
3
1
2
4
5
6
Figure 14
CONTROL DESCRIPTION
1. CAVITY LIGHTS ON/OFF - Operates the
oven cavity lights.
2. BLOWER ON/OFF SWITCH - Controls the
operation of the blower. If the blower switch is
in the OFF position the oven will be turned off.
3. COOL DOWN SWITCH - When the switch is
in the AUTO position, the oven can be used to
cook. When the switch is in the MAN position,
the oven is cooling down for the next bake.
4. OVEN READY LIGHT
Ć When lit indicates burnĆ
ers are operating. When the light goes out the
oven has reached operating temperature.
5. THERMOSTAT Ć Controls the temperature at
which the oven will operate. Temperatures
can range from 200Ć500
_
F (93Ć260
_
C).
6. COOK TIMER Ć Used to time the length of the
cooking operation. When the set time expires,
a buzzer will sound.
OPERATION
1. Set the COOL DOWN switch (3) to the AUTO
position. Turn the THERMOSTAT (5) to the deĆ
sired operating temperature.
2. Set the BLOWER ON/OFF SWITCH (2) to the
ON
position. When the OVEN READY light (4)
goes out, load the product and set the COOK
TIMER (6).
3. When the timer sounds, remove the product.
If the next product requires a lower operating
temperature, then the cool down mode can be
used. Turn the COOL DOWN SWITCH (3) to
the MAN position. Make sure that the door is
open.
4. Turn the oven off by setting the BLOWER ON/
OFF SWITCH (2) to the
OFF
position.
WARNING!!
A complete five minute shutdown must be