Installation
11
Electrical Connection
Before making any electrical connections to this
unit, check that the power supply is adequate for
the voltage, amperage, and phase requirements
stated on the rating plate.
NOTE: The rating plate is mounted on the control
box.
A wiring diagram accompanies this manual and is
also attached inside the control panel.
The MT3255E is available in two voltage options.
D
The 380/220 VAC oven requires a 60 Amp,
50Hz,
3
Φ
,
4 wire service consisting of L1, L2
neutral and ground.
D
The 415/240 oven requires a 60 Amp, 50Hz, 3
Φ
,
3 wire service consisting of L1, neutral and
ground.
Use 90
_
C wire and size wire according to local
codes.
415/
380
L1
L2
L3
Oven
Supply
N
415/380
415/380
240/
220
Figure 17
THE BLODGETT OVEN COMPANY CANNOT AS-
SUME RESPONSIBILITY FOR LOSS OR DAMAGE
SUFFERED AS A RESULT OF IMPROPER INSTAL-
LATION.