22
S
EXPOSURE CONTROLS/PERSONAL PROTECTION
ENGINEERING CONTROLS: Provide general and/or local exhaust ventilation to control
airborne levels below the exposure guidelines.
PERSONAL PROTECTIVE EQUIPMENT
EYE/FACE PROTECTION: Use safety glasses. Safety glasses should be sufficient for most
operations; however, for misty operations wear chemical goggles.
SKIN PROTECTION: Use gloves impervious to this material.
RESPIRATORY PROTECTION: Atmospheric levels should be maintained below the exposure
guideline. When respiratory protection is required for certain operations, use an approved air-
purifying respirator. In misty atmospheres, use an approved mist respirator.
EXPOSURE GUIDELINES: Propylene glycol: AIHA WEEL is 50 ppm total, 10 mg/m3 aerosol
only.
9. PHYSICAL AND CHEMICAL PROPERTIES
APPEARANCE/PHYSICAL STATE:
Clear yellow liquid.
ODOUR:
Odourless
VAPOR PRESSURE:
0.22 mmHg @ 20
Ε
C
VAPOR DENSITY:
2.6
BOILING POINT:
320
Ε
F, 160
Ε
C
SOLUBILITY IN WATER/MISCIBILITY:
Complete
SPECIFIC GRAVITY OR DENSITY:
1.058 @ 25/25
Ε
C
* or (R) indicates a trademark of The Dow Chemical Company.
10. STABILITY AND REACTIVITY
CHEMICAL STABILITY: Thermally stable at typical use temperatures.
CONDITIONS TO AVOID: Avoid use temperatures above 450
Ε
F, 232
Ε
C. Product can
degrade
at elevated temperatures. Generation of gas during decomposition can cause pressure in
closed systems.