Installation
Description and Specifications
ELECTrICAL rATINGS- CTB-G, CTBr-G, CTB-GFB & CTBr-GFB
hz
VOLTAGE
kw
phASE
MAx LOAD (AMpS)
ELECTrICAL CONNECTION
AwG*
L1
L2
L2
N
CTB-G or CTBr-G
60
208
16.8
1
75
0
75
—
2
16.8
3
43
43
43
—
6
240
16.8
1
65
0
65
—
3
16.8
3
38
38
38
—
6
CTB-GFB or CTBr-GFB
60
208
17.6
1
85
0
85
—
1
17.6
3
49
49
49
—
4
240
17.6
1
73
0
73
—
2
17.6
3
42
42
42
—
6
* Electric connection wiring is sized for 60
º
C copper wire at 125% of rated input.
NOTE: Double units can have phase loads partially equalized by matching lines during hook-up. Otherwise, CTB-Double
or CTBR-Double load ratings are twice the above data.
The Blodgett Cooktop models offer versatility of convection and range top cooking within a small footprint.The Blodgett
Cooktop is offered in four different configurations:
•
CTB-GFB
- CTB oven base with 18” griddle on the left and 2 french top burners on the right
•
CTBr-GFB
- CTBR oven base with 18” griddle on the right and 2 french top burners on the left
•
CTB-G
- CTB oven base with 30” wide griddle
•
CTBr-G
- CTBR oven base with 30” wide griddle