BCP & BCM
,
ERROR CODES & CAUSES
3
-
Generator Hot
– Generator High Limit Thermostat Open(Opens at 275˚F) (Manual Reset under a
cover at the bottom of the control panel)
4
–
Oven Hot
- Oven High Limit Thermostat Open (Opens at 662˚F) (Manual Reset under a cover at the
bottom of the control panel)
5
–
Fan Hot
– Motor Thermal Limit Open (2 Gray Wires) (Opens at 320˚F) Wait 10 minutes and try again.
If 5 appears again, the cooling fans, motor bearings, or thermal switch within the motor failed.
6
–
Drain Hot
– RTD Probe in Drain (100 Ohm Probe) reads over 167˚F for over 5 minutes.
7
–
Oven sensor Defect
– RTD Probe in Generator (100 Ohm Probe) Shorted/Open
8
–
Core Probe Missing
– Control has an active Core (Meat) Probe. Deactivate both Core Probes or
insert Core Probe in the probe port on the control side.
9
–
Gen Sensor Defect
– RTD Probe in Generator (100 Ohm Probe) Shorted/Open
10
–
Drain Sensor Defect
- RTD Probe in Drain (100 Ohm Probe) Shorted/Open
11
–
Water Shortage
– Steam Generator could did fill in 5 minutes.
12
–
SSR Hot
– one of the two SSR Heat Sink Automatic Reset Snap Disks that are wired in series is Open
(Open at 248˚F)
13
–
Generator > 265
– RTD Probe in Generator (100 Ohm Probe)reads over 265˚F.
14
–
Fan Slow
– Fan Hall Sensor (Brown, Black and Red Wires), Inverter or the Motor has failed or a
wiring issue exists.
16
–
IO Board Hot
– The IO Board senses a temperature above 140˚F.
19
–
Internal Error
–The control has sensed a failed process, restart the control.
20
–
IO Com Error
- Failure of communication between the CPU and IO Board.
21
–
Invalid recipe
– Indicates a recipe is programmed for a feature the oven does not have.
22
-
Program Terminated
– Power interrupted while a program was in progress and enough time
elapsed that the program cannot resume.
24
–
Empty Error
– Steam Generator water level sensor reads water 25 seconds after running the drain
pump to drain the boiler.
25
–
CombiOptima not Calibrated
– Enter the Service Menu and run the calibration.
26
–
CombiOptima Sensor Error
– The Pressure sensor gives a reading outside the range of 0.5 - 4.5.
27
–
CombiOptima calibr. Fault
– Calibration could not be completed, Start calibration when the oven is
cold and dry.