大型风扇行业的领航者
2. Attach the cables to the fan frame using the open end chain links. Install two cableclamps,
pull up the slack in the cable, and tighten the clamp that is furthest from the fan.
3.
Using the supplied tensioning tool it fits on your 3/8”drive ratchet, tension the cables and
tighten the inner cable clamp (while holding tension with the tool). It's best to take a couple of
turns around, tightening each cable a bit at a time. You may
want to put a level on the hub to
make sure you don't tip the fan.
Note:
The key to insuring that cables stay tight is making sure the have fair amount of tension
on them to begin with.
4.
Loosen the outermost clamp, take up the slack, and retighten the clamp so that both clamps
are holding the tension.
Start-up Procedure
■ Turn switch to the ON position, when power is applied, the green 'On' indicator (located on
the front of panel) will light.
■Adjust the speed control knob as needed.
■ Turn the Fwd-Off-Rev (Forward/Off/Reverse) to the Fwd (Forward) position.
■ After a 3 second delay, the fan will begin to accelerate slowly
■ Verify proper rotation with switch in the Fwd position, the rotor should be turning in
counter-clockwise direction when viewed from the floor.
23