background image

Page 4

RokBox™ EXA Manual Rev. A  

 

 

© 2013 Blizzard Lighting, LLC

SAFETY INSTRUCTIONS

•  Please keep this User Guide for future use. If you sell the unit to someone 

else, be sure that they also receive this User Guide.

•  ALWAYS make sure that you are connecting to the proper voltage, and that 

the line voltage you are connecting to is not higher than that stated on the de-

cal or rear panel of the fixture.

•  This product is intended for indoor use only.

•  To prevent risk of fire or shock, do not expose fixture to rain or moisture. 

•  Make sure there are no flammable materials close to the unit while operating.

•  The unit must be installed in a location with adequate ventilation, at least 

20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are 

blocked.

•  ALWAYS disconnect from the power source before servicing or replacing fuse 

and be sure to replace with same fuse size and type.

•  ALWAYS secure fixture using a safety chain. NEVER carry the fixture by its 

cord. Use its carrying handles.

•  DO NOT operate at ambient temperatures higher than 104°F (40°C).

•  In the event of a serious operating problem, stop using the unit immediately. 

NEVER try to repair the unit by yourself. Repairs carried out by unskilled people 

can lead to damage or malfunction. Please contact the nearest authorized tech-

nical assistance center. Always use the same type spare parts.

•  NEVER connect the device to a dimmer pack.

•  Make sure the power cord is never crimped or damaged.

•  Never disconnect the power cord by pulling or tugging on the cord.

•  Avoid direct eye exposure to the light source while it is on.

Caution! 

There are no user serviceable parts inside the unit. Do not 

open the housing or attempt any repairs yourself. In the unlikely event 

your unit may require service, please contact Blizzard Lighting at sup

-

[email protected].

Summary of Contents for rokbox exa

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2013 exa TM rokbox...

Page 2: ...AR Cans 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 Using this fixture with the w...

Page 3: ...to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure that...

Page 4: ...icing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at am...

Page 5: ...nstant current 400hz LED driver 3 pin male input and 3 pin female output PowerCon compatible AC power In Out connectors DMX Quick Reference 8 10 11 Channel Mode Channel 8 Channel 10 Channel 11 Channel...

Page 6: ...g LLC Figure 1 The RokBox EXA Pin Up Picture High Power 6 in 1 RGBAW UV LEDs Heavy Duty Cast Aluminum Enclosure Dual Mounting Yokes Adjustment Locking Knobs Figure 2 The Rear Connections AC Power Out...

Page 7: ...n a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deteriora...

Page 8: ...to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Conn...

Page 9: ...perating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enou...

Page 10: ...ES IS BLIZZARD LIGHTING RESPONSIBLE FOR ANY DAMAGE FROM SUCH OPERATION Fixtures bearing the above logo MUST only use cable and connec tors which separate chassis case ground from cable shielding Cabli...

Page 11: ...and verify it is receiving power the STATUS LED should illuminate 2 Connect the AC DC adaptor to the wiCICLE Transmitter and verify it is re ceiving power the STATUS LED should illuminate 3 Press the...

Page 12: ...lls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the menu map o...

Page 13: ...de SP SP00 SP15 Speed adjustments 0 15 Pr Pr00 Pr35 Built in programs 0 35 ASC AC00 AC15 Auto mode 0 15 FAdE FA00 FA15 Fade settings 0 15 FLAS FL00 FL15 Flash strobe speed 0 15 rL r 000 r 255 Red dimm...

Page 14: ...confirm 3 To use the fixture in automatic mode select ASC and press the ENTER button Then use the UP DOWN to choose from AS00 AS15 then press the ENTER button to confirm 4 Adjust the speed of the cha...

Page 15: ...005 006 055 056 105 106 155 156 205 206 255 32 Bit Dimmer As set in the control menu display Mode 0 8 bit 256 dimming steps Mode 1 32 bit 0 25 intensity range Mode 2 32 bit 0 50 intensity range Mode 3...

Page 16: ...o Verify that the fixture is in Sound Active mode Fixture Not Responding Responding Erraticly Make sure all connectors are seated properly and securely Use Only DMX Cables and or check cables for defe...

Page 17: ...n mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the firs...

Page 18: ...action and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit...

Page 19: ...3 6 8 10 11 Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Sound Active Color Preset Other Information For mad scientists who keep brains in jars here s a...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: