background image

Page 8

             The Puck: Unplugged RGBA Manual Rev. A 

 

Copyright (c) 2011 Blizzard Lighting, LLC

3. SETUP

Fuse Replacement

With a fl at head screwdriver, wedge the 

fuse holder out of its housing. Remove the 

damaged fuse from its holder and replace 

with exact same type fuse. Insert the fuse 

holder back in its place and reconnect 

power.

Connecting A Bunch of The Puck: UNPLUGGED™ RGBA Flat LED 

PAR Cans
You will need a serial data link to run light shows using a DMX-512 

controller or to run shows on two or more fi xtures set to sync in mas-

ter/slave operating mode. The combined number of channels required 

by all the fi xtures on a serial data link determines the number of fi x-

tures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. 

Also, connecting more than 32 fi xtures on one serial data link without 

the use of a DMX optically-isolated splitter may result in deterioration 

of the digital DMX signal.

The maximum recommended cable-run distance is 500 meters (1640 

ft).  The maximum recommended number of fi xtures on a serial data 

link is 32 fi xtures.

Data/DMX Cabling
To link fi xtures together you’ll need data cables.  You should use data-

grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference.

For instance, Belden© 9841 meets the specifi cations for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but 

note that they cannot transmit DMX data as reliably over long distanc-

es.  In any event, the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Summary of Contents for Puck RGBA Unplugged

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Wisconsin USA Copyright c 2011...

Page 2: ...A LED PAR Can 6 Features 6 DMX Quick Reference 4 and 7 Channel Modes 6 The Puck UNPLUGGED RGBA Pin up Picture 7 3 Setup 8 Fuse Replacement 8 Connecting A Bunch Of Puck UNPLUGGED RGBAs 8 Data DMX Cable...

Page 3: ...f the bat tery pack 5 DO NOT BURN OR INCINERATE BATTERY PACKS Battery packs may explode causing personal injury fire and or damage Fumes resulting from burning of battery packs may be toxic 6 DO NOT D...

Page 4: ...or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you rec...

Page 5: ...e before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT...

Page 6: ...RES Lightweight and Compact It kept its New Years resolution High output long running Lithium Ion rechargable battery system 4 Button LED control panel for easy programming Light source 144x 10mm LEDs...

Page 7: ...Rev A Copyright c 2011 Blizzard Lighting LLC Figure 1 The Puck UNPLUGGED RGBA Pin Up Picture High Power LEDs Ridiculously thin Dual Mounting Yokes Figure 2 The Rear Connections AC Power In Out DMX In...

Page 8: ...ecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distan...

Page 9: ...e is set to slave mode simply plug the wiCICLE receiver into the DMX IN connector on the back of the fixture The fixture will automatically detect and power the wiCICLE Follow the instructions provide...

Page 10: ...e Fixture From The Battery 1 Switch the top switch to position I BAT ON 2 Switch the bottom switch to position O OFF To Operate The Fixture From AC Power 1 Switch the top switch to position O BAT OFF...

Page 11: ...y using the UP DOWN keys to reach SLAV in the Master Auto menu on the slave units and they will react in the same as the Master Slave SLNd then SLAu to confirm 4 On the master fixture use the UP DOWN...

Page 12: ...lown Fuse Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct po...

Page 13: ...your cli ent s satistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit...

Page 14: ...Angle 21 degrees 32 degree field Luminous Intensity 2 995 Lux 1m Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 4 or 7 User Selectable Input...

Page 15: ...Page 15 The Puck Unplugged RGBA Manual Rev A Copyright c 2011 Blizzard Lighting LLC Thine pagest hath beenst lefteth blanketh on purposeth...

Page 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: